Reduction of BOLD interference in pseudo-continuous arterial spin labeling: towards quantitative fMRI

被引:2
|
作者
Warnock, Geoffrey [1 ]
Oezbay, Pinar S. [2 ,3 ,4 ,5 ]
Kuhn, Felix P. [2 ]
Nanz, Daniel [2 ]
Buck, Alfred [1 ]
Boss, Andreas [2 ]
Rossi, Cristina [2 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Nucl Med, Zurich, Switzerland
[2] Univ Zurich, Inst Diagnost & Intervent Radiol, Univ Hosp Zurich, Raemistr 100, CH-8091 Zurich, Switzerland
[3] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[4] Swiss Fed Inst Technol, Zurich, Switzerland
[5] NINDS, Adv MRI Sect, Lab Funct & Mol Imaging, NIH, Bldg 36,Rm 4D04, Bethesda, MD 20892 USA
关键词
Arterial spin labelling; cerebral blood flow measurement; MRI; positron emission tomography; CEREBRAL-BLOOD-FLOW; POSITRON-EMISSION-TOMOGRAPHY; PERFUSION MRI; FIELD-STRENGTH; WHOLE-BRAIN; 3.0; T; CAFFEINE; ECHO; PET; SENSITIVITY;
D O I
10.1177/0271678X17704785
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fluctuations in blood-oxygenation level dependent (BOLD) signal and perfusion affect the quantification of changes in cerebral blood flow (CBF), coupled to neuronal activity, in arterial spin labeling (ASL). Subtraction methods for control and labeled MR images (i.e. pair-wise, surround subtraction, and subtraction of sinc-interpolated images), postulated to mitigate this interference in pseudo-continuous ASL (pCASL), were evaluated by comparison with quantitative O-15-water PET. At rest, a good agreement in the CBF values was found between PET and MRI for each of the subtraction methods. Stimulation of the visual system resulted in a regional CBF increase in the occipital lobe, which was detectable in both modalities. Bland-Altman analysis showed a systematic underestimation of the CBF values during activation in MRI. Evaluation of the relative CBF change induced by neuronal stimulation showed good inter-modality agreement for the three subtraction methods. Perfusion data obtained with each subtraction method followed the stimulation paradigm without significant differences in the correlation patterns or in the time lag between stimulation and perfusion response. Comparison to the gold standard confirmed the detectability of a neuronal stimulation pattern by pCASL. The results indicate that the combined use of background suppression and short TE reduces the BOLD-weighting in the pCASL signal.
引用
收藏
页码:847 / 856
页数:10
相关论文
共 50 条
  • [31] Spatial-temporal perfusion patterns of the human liver assessed by pseudo-continuous arterial spin labeling MRI
    Martirosian, Petros
    Pohmann, Rolf
    Schraml, Christina
    Schwartz, Martin
    Kuestner, Thomas
    Schwenzer, Nina Franziska
    Scheffler, Klaus
    Nikolaou, Konstantin
    Schick, Fritz
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (02): : 173 - 183
  • [32] Pseudo-continuous arterial spin labeling MRI study of patients with obsessive-compulsive disorder
    Ota, Miho
    Kanie, Ayako
    Kobayashi, Yuki
    Nakajima, Aiichiro
    Sato, Noriko
    Horikoshi, Masaru
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2020, 303
  • [33] Test-retest reliability of perfusion of the precentral cortex and precentral subcortical white matter on three-dimensional pseudo-continuous arterial spin labeling
    Liu, Mengqi
    Chen, Zhiye
    Ma, Lin
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2018, 46 (09) : 3788 - 3795
  • [34] Investigation of control scans in pseudo-continuous arterial spin labeling (pCASL): Strategies for improving sensitivity and reliability of pCASL
    Han, Paul Kyu
    Choi, Seung Hong
    Park, Sung-Hong
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (03) : 917 - 929
  • [35] Pseudo-continuous arterial spin labeling technique for measuring CBF dynamics with high temporal resolution
    Silva, AC
    Kim, SG
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (03) : 425 - 429
  • [36] A constrained slice-dependent background suppression scheme for simultaneous multislice pseudo-continuous arterial spin labeling
    Shao, Xingfeng
    Wang, Yi
    Moeller, Steen
    Wang, Danny J. J.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) : 394 - 400
  • [37] Interpulse phase corrections for unbalanced pseudo-continuous arterial spin labeling at high magnetic field
    Hirschler, Lydiane
    Debacker, Clement S.
    Voiron, Jerome
    Koehler, Sascha
    Warnking, Jan M.
    Barbier, Emmanuel L.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1314 - 1324
  • [38] Pseudo-continuous arterial spin labeling at 7 T for human brain: Estimation and correction for off-resonance effects using a Prescan
    Luh, Wen-Ming
    Talagala, S. Lalith
    Li, Tie-Qiang
    Bandettini, Peter A.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (02) : 402 - 410
  • [39] High-Resolution Mouse Kidney Perfusion Imaging by Pseudo-Continuous Arterial Spin Labeling at 11.75T
    Duhamel, Guillaume
    Prevost, Valentin
    Girard, Olivier M.
    Callot, Virginie
    Cozzone, Patrick J.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 1186 - 1196
  • [40] Optimization of pseudo-continuous arterial spin labeling using off-resonance compensation strategies at 7T
    Saib, Gael
    Koretsky, Alan P.
    Talagala, S. Lalith
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (04) : 1720 - 1730