Reduction of BOLD interference in pseudo-continuous arterial spin labeling: towards quantitative fMRI

被引:2
|
作者
Warnock, Geoffrey [1 ]
Oezbay, Pinar S. [2 ,3 ,4 ,5 ]
Kuhn, Felix P. [2 ]
Nanz, Daniel [2 ]
Buck, Alfred [1 ]
Boss, Andreas [2 ]
Rossi, Cristina [2 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Nucl Med, Zurich, Switzerland
[2] Univ Zurich, Inst Diagnost & Intervent Radiol, Univ Hosp Zurich, Raemistr 100, CH-8091 Zurich, Switzerland
[3] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[4] Swiss Fed Inst Technol, Zurich, Switzerland
[5] NINDS, Adv MRI Sect, Lab Funct & Mol Imaging, NIH, Bldg 36,Rm 4D04, Bethesda, MD 20892 USA
关键词
Arterial spin labelling; cerebral blood flow measurement; MRI; positron emission tomography; CEREBRAL-BLOOD-FLOW; POSITRON-EMISSION-TOMOGRAPHY; PERFUSION MRI; FIELD-STRENGTH; WHOLE-BRAIN; 3.0; T; CAFFEINE; ECHO; PET; SENSITIVITY;
D O I
10.1177/0271678X17704785
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fluctuations in blood-oxygenation level dependent (BOLD) signal and perfusion affect the quantification of changes in cerebral blood flow (CBF), coupled to neuronal activity, in arterial spin labeling (ASL). Subtraction methods for control and labeled MR images (i.e. pair-wise, surround subtraction, and subtraction of sinc-interpolated images), postulated to mitigate this interference in pseudo-continuous ASL (pCASL), were evaluated by comparison with quantitative O-15-water PET. At rest, a good agreement in the CBF values was found between PET and MRI for each of the subtraction methods. Stimulation of the visual system resulted in a regional CBF increase in the occipital lobe, which was detectable in both modalities. Bland-Altman analysis showed a systematic underestimation of the CBF values during activation in MRI. Evaluation of the relative CBF change induced by neuronal stimulation showed good inter-modality agreement for the three subtraction methods. Perfusion data obtained with each subtraction method followed the stimulation paradigm without significant differences in the correlation patterns or in the time lag between stimulation and perfusion response. Comparison to the gold standard confirmed the detectability of a neuronal stimulation pattern by pCASL. The results indicate that the combined use of background suppression and short TE reduces the BOLD-weighting in the pCASL signal.
引用
收藏
页码:847 / 856
页数:10
相关论文
共 50 条
  • [21] The costs and benefits of estimating T1 of tissue alongside cerebral blood flow and arterial transit time in pseudo-continuous arterial spin labeling
    Bladt, Piet
    den Dekker, Arnold J.
    Clement, Patricia
    Achten, Eric
    Sijbers, Jan
    NMR IN BIOMEDICINE, 2020, 33 (12)
  • [22] Comparison of relative cerebral blood flow maps using pseudo-continuous arterial spin labeling and single photon emission computed tomography
    Liu, Peiying
    Uh, Jinsoo
    Devous, Michael D.
    Adinoff, Bryon
    Lu, Hanzhang
    NMR IN BIOMEDICINE, 2012, 25 (05) : 779 - 786
  • [23] Improving the robustness of pseudo-continuous arterial spin labeling to off-resonance and pulsatile flow velocity
    Zhao, Li
    Vidorreta, Marta
    Soman, Salil
    Detre, John A.
    Alsop, David C.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (04) : 1342 - 1351
  • [24] Cerebral Perfusion in Adolescent Major Depression: A Pseudo-Continuous Arterial Spin Labeling Study
    Ho, Tiffany C.
    Wu, Jing
    Shin, David D.
    Yang, Guang
    Banerjee, Dipavo
    Connolly, Colm G.
    Hendren, Robert
    Simmons, Alan G.
    Yang, Tony
    BIOLOGICAL PSYCHIATRY, 2013, 73 (09) : 165S - 165S
  • [25] Designing and comparing optimized pseudo-continuous Arterial Spin Labeling protocols for measurement of cerebral blood flow
    Woods, Joseph G.
    Chappell, Michael A.
    Okell, Thomas W.
    NEUROIMAGE, 2020, 223
  • [26] Heritability of Cerebral Blood Flow and the Correlation to Schizophrenia Spectrum Disorders: A Pseudo-continuous Arterial Spin Labeling Twin Study
    Legind, Christian S.
    Broberg, Brian V.
    Brouwer, Rachel
    Mandl, Rene C. W.
    Ebdrup, Bjorn H.
    Anhoj, Simon J.
    Jensen, Maria H.
    Hilker, Rikke
    Fagerlund, Birgitte
    Pol, Hilleke E. Hulshoff
    Glenthoj, Birte Y.
    Rostrup, Egill
    SCHIZOPHRENIA BULLETIN, 2019, 45 (06) : 1231 - 1241
  • [27] Test-retest reliability and reproducibility of long-label pseudo-continuous arterial spin labeling
    Lin, Tianye
    Qu, Jianxun
    Zuo, Zhentao
    Fan, Xiaoyuan
    You, Hui
    Feng, Feng
    MAGNETIC RESONANCE IMAGING, 2020, 73 : 111 - 117
  • [28] Optimization and reliability of multiple postlabeling delay pseudo-continuous arterial spin labeling during rest and stimulus-induced functional task activation
    Mezue, Melvin
    Segerdahl, Andrew R.
    Okell, Thomas W.
    Chappell, Michael A.
    Kelly, Michael E.
    Tracey, Irene
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2014, 34 (12) : 1919 - 1927
  • [29] Cerebral perfusion alterations in patients with trigeminal neuralgia as measured by pseudo-continuous arterial spin labeling
    Zhou, Qianling
    Li, Meng
    Fan, Qisen
    Chen, Feng
    Jiang, Guihua
    Wang, Tianyue
    He, Qinmeng
    Fu, Shishun
    Yin, Yi
    Lin, Jinzhi
    Yan, Jianhao
    FRONTIERS IN NEUROSCIENCE, 2022, 16
  • [30] Neural plasticity secondary to carpal tunnel syndrome: a pseudo-continuous arterial spin labeling study
    Deng, Xue
    Chau, Phoebe Lai-Heung
    Chiu, Suk-Yee
    Leung, Kwok-Pui
    Hu, Yong
    Ip, Wing-Yuk
    NEURAL REGENERATION RESEARCH, 2021, 16 (01) : 158 - 165