Comparison of clinical diagnostic value of spiral CT with different dose in patients with early-stage peripheral lung cancer

被引:2
|
作者
Sun, Y. J. [1 ]
Lou, J. [2 ]
Xu, Q. L. [3 ]
Xing, Y. G. [4 ]
Zhao, X. Z. [5 ]
Zhao, L. L. [6 ]
Wang, X. N. [7 ]
机构
[1] Peoples Hosp Rizhao, Dept Radiol, Rizhao 276826, Peoples R China
[2] Jinan Zhangqiu Dist Hosp TCM, Dept Gen Surg Ward, Jinan 250200, Peoples R China
[3] Peoples Hosp Zhangqiu Area, Hlth Care Ward, Jinan 250200, Peoples R China
[4] Peoples Hosp Zhangqiu Area, Dept Ultrasound, Jinan 250200, Peoples R China
[5] Peoples Hosp Zhangqiu Area, Pediat Ward 2, Jinan 250200, Peoples R China
[6] Peoples Hosp Rizhao, Dept Resp Med, Rizhao 276826, Peoples R China
[7] Qingdao 6 Peoples Hosp, Dept Radiol, 9 Fushun Rd, Qingdao 266033, Peoples R China
来源
CLINICAL & TRANSLATIONAL ONCOLOGY | 2021年 / 23卷 / 06期
关键词
Dose; Spiral CT; Early-stage peripheral lung cancer; Diagnostic value; COMPUTED-TOMOGRAPHY; PREVALENCE;
D O I
10.1007/s12094-020-02503-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose To compare the clinical diagnostic value of spiral CT scan with different dose in patients with early-stage peripheral lung cancer. Methods A total of 163 cases of patients with early-stage peripheral lung cancer who came to People's Hospital of Rizhao for treatment from June 2014 to January 2017 were retrospectively analyzed. A total of 78 cases of patients who received low-dose CT scanning were the low-dose group, another 84 cases of patients who received routine dose CT scanning were the routine dose group. Multislice helical CT (MSCT) scanning was performed in both groups, with tube voltage of 120 kV. Tube current was 25 m A in the low-dose group and 250 m A in the routine dose group. In addition, a total of 80 patients with lobar pneumonia were added as the control group of diagnostic sensitivity, specificity and accuracy. Pathological diagnosis was taken as the gold standard to compare the diagnostic sensitivity, specificity and accuracy of the two groups. Results The image quality, nodules and signs of the two groups were compared, and the results of radiation dose of the two groups were compared. The diagnostic sensitivity, specificity and accuracy of the low-dose group were 82.05%, 87.50% and 84.81%, respectively. The diagnostic sensitivity, specificity and accuracy of the routine dose group were 85.71%, 86.25% and 85.97%, respectively. The diagnostic value of the two groups was not statistically significant (p > 0.05). However, the radiation dose in the low-dose group was significantly lower than that in the routine group. Conclusion Low-dose MSCT scanning can meet the clinical requirements for imaging diagnosis of peripheral lung cancer, and can reduce the radiation dose of patients.
引用
收藏
页码:1128 / 1133
页数:6
相关论文
共 50 条
  • [41] Preliminary Study on Diagnostic Value of Artificial Intelligence in Early Stage Lung Cancer
    Zhao, L.
    Bai, C.
    Zhu, Y.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [42] Response to Clinical Thoughts on Mediastinal Node Management in Early-Stage Lung Cancer
    Osarogiagbon, Raymond U.
    Ray, Meredith A.
    Faris, Nicholas R.
    Smeltzer, Matthew P.
    JOURNAL OF THORACIC ONCOLOGY, 2020, 15 (11) : E185 - E186
  • [43] ASO Author Reflections: The Clinical Use of Radiomics with Artificial Intelligence in Patients with Early-Stage Lung Cancer
    Yoshihisa Shimada
    Annals of Surgical Oncology, 2022, 29 : 8194 - 8195
  • [44] ASO Author Reflections: The Clinical Use of Radiomics with Artificial Intelligence in Patients with Early-Stage Lung Cancer
    Shimada, Yoshihisa
    ANNALS OF SURGICAL ONCOLOGY, 2022, 29 (13) : 8194 - 8195
  • [45] Liquid Biopsy in Early-Stage Lung Cancer: Current and Future Clinical Applications
    Vandekerckhove, Olivia
    Cuppens, Kristof
    Pat, Karin
    Du Pont, Bert
    Froyen, Guy
    Maes, Brigitte
    CANCERS, 2023, 15 (10)
  • [46] Laparoscopy or laparotomy? A comparison of 240 patients with early-stage endometrial cancer
    Santi, Alessandro
    Kuhn, Annette
    Gyr, Thomas
    Eberhard, Markus
    Johann, Silke
    Guenthert, Andreas R.
    Mueller, Michael D.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2010, 24 (04): : 939 - 943
  • [47] Clinical implication of interstitial lung abnormality in elderly patients with early-stage non-small cell lung cancer
    Cho, Seong Woo
    Jeong, Won Gi
    Lee, Jong Eun
    Oh, In-Jae
    Song, Sang Yun
    Park, Hye Mi
    Lee, Hyo-Jae
    Kim, Yun-Hyeon
    THORACIC CANCER, 2022, 13 (07) : 977 - 985
  • [48] Diagnostic Value of Spectral CT Parameters in Differentiating Different Types of Lung Cancer
    Chen, Mai-Lin
    Li, Xiao-Ting
    Wei, Yi-Yuan
    Qi, Li-Ping
    Sun, Ying-Shi
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2020, 10 (08) : 1804 - 1808
  • [49] Laparoscopy or laparotomy? A comparison of 240 patients with early-stage endometrial cancer
    Alessandro Santi
    Annette Kuhn
    Thomas Gyr
    Markus Eberhard
    Silke Johann
    Andreas R. Günthert
    Michael D. Mueller
    Surgical Endoscopy, 2010, 24 : 939 - 943
  • [50] CLINICAL DIAGNOSIS AND VALUE ANALYSIS MULTILAYER SPIRAL CT SCAN IN EARLY PANCREATIC CANCER IN RETIRE ATHLETIC PATIENTS
    Qin, Yanlei
    Liu, Weihong
    Yu, Huili
    Zhang, Rongrong
    REVISTA INTERNACIONAL DE MEDICINA Y CIENCIAS DE LA ACTIVIDAD FISICA Y DEL DEPORTE, 2023, 23 (89): : 76 - 85