Determination of deltamethrin in rat plasma and brain using gas chromatography-negative chemical ionization mass spectrometry

被引:13
|
作者
Gullick, Darren [1 ]
Popovici, Andrew [1 ]
Young, Holly C. [1 ]
Bruckner, James V. [1 ]
Cummings, Brian S. [1 ]
Li, Pei [1 ]
Bartlett, Michael G. [1 ]
机构
[1] Univ Georgia, Coll Pharm, Dept Pharmaceut & Biomed Sci, Athens, GA 30602 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2014年 / 960卷
关键词
Deltamethrin; Pyrethroids; Neurotoxicity; Plasma; Brain homogenate; Bioanalytical method validation; PYRETHROID INSECTICIDES; HUMAN URINE; NEUROTOXICITY; METABOLITES; CYPERMETHRIN; TOXICITY; CHILDREN; AGE;
D O I
10.1016/j.jchromb.2014.04.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quantification of the pyrethroid deltamethrin (DLM) in small (100 mu L) biological samples from rodents is essential for toxicokinetic studies of trace levels of the insecticide in foods. Such empirical kinetic data are necessary for construction of valid physiologically-based toxicokinetic models. There are no validated methods in the literature for determining deltamethrin in 100 mu L plasma and brain samples. Plasma and brain samples were stabilized using sodium fluoride as an esterase inhibitor, and the DLM was extracted by protein precipitation using acetonitrile and phosphoric acid. The samples were vortexed, centrifuged, evaporated to dryness, and reconstituted in toluene prior to injection into a gas chromatograph equipped with a quadrupole mass analyzer. Samples were ionized via electron capture in the negative ion mode using methane, and the molecular ion and fragment ions of DLM were monitored using Selected-Ion Monitoring (SIM) for quantitation and verification of the analyte. Cis-permethrin was used as the internal standard for the method, which was validated according to current US FDA guidelines. Linearity was determined between 0.3 and 1000 ng/mL, with a limit of detection of 150 pg/mL. The intra- and inter-batch variation for precision (as % relative standard deviation, RSD) and accuracy (as % bias) of the method were better than 20% at the limit of quantitation and better than 15% across the remaining linear range (n = 18), with recoveries of 113% and 68% for plasma and brain respectively. Benchtop stability, autosampler stability, and freeze/thaw stability studies of the method (over a 3-day freeze/thaw cycle) were found to be within the acceptance criteria of 20% RSD and bias. This optimized method was applied to the quantitation of DLM in plasma and brain homogenate samples obtained up to 12 h after oral dosing of Sprague-Dawley rats with 1 mg DLM/kg body weight. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:158 / 165
页数:8
相关论文
共 50 条
  • [1] Quantitative determination of clonazepam in plasma by gas chromatography-negative ion chemical ionization mass spectrometry
    Song, DM
    Zhang, S
    Kohlhof, K
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (02): : 199 - 204
  • [2] DETERMINATION OF FLUMAZENIL IN PLASMA BY GAS CHROMATOGRAPHY-NEGATIVE ION CHEMICAL-IONIZATION MASS-SPECTROMETRY
    SONG, DM
    KHAYKIS, V
    KOHLHOF, K
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 663 (02): : 263 - 273
  • [3] Determination of cyflufenamid residue in carrots by gas chromatography-negative chemical ionization mass spectrometry
    Yang Wenquan
    Shen Weijian
    Zhao Zengyun
    Xu Jinzhong
    Shen Chongyu
    Wu Bin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (04) : 526 - 528
  • [4] Determination of Difenoconazole Residue in Foods by Gas Chromatography-Negative Chemical Ionization Mass Spectrometry
    Shen Weijian
    Yang Wenquan
    Shen Chongyu
    Zhao Zengyun
    Xu Jinzhong
    Ding Tao
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2007, 25 (03) : 418 - 421
  • [5] Simultaneous determination of cis-permethrin and trans-permethrin in rat plasma and brain tissue using gas chromatography-negative chemical ionization mass spectrometry
    Hooshfar, Shirin
    Gullick, Darren R.
    Linzey, Michael R.
    Mortuza, Tanzir
    Rahman, Mona Hamdy Abdel
    Rogers, Clinton A.
    Bruckner, James V.
    White, Catherine A.
    Bartlett, Michael G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1060 : 291 - 299
  • [6] Gas chromatography/negative chemical ionization mass spectrometry of transfluthrin in rat plasma and brain
    Hooshfar, Shirin
    Mortuza, Tanzir B.
    Rogers, Clinton A.
    Linzey, Michael R.
    Gullick, Darren R.
    Bruckner, James V.
    White, Catherine A.
    Bartlett, Michael G.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (19) : 1573 - 1581
  • [7] Enantioselective gas chromatography-negative ion chemical ionization mass spectrometry for methylphenidate in human plasma
    Lin, SN
    Andrenyak, DM
    Moody, DE
    Foltz, RL
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1999, 23 (06) : 524 - 530
  • [8] Determination of pyrethroid pesticide residues by gas chromatography-negative chemical ionization mass spectrometry and its application
    Shen Chongyu
    Shen Weijian
    Jiang Yuan
    Xu Jinzhong
    Zhao Zengyun
    Chen Huilan
    Wu Bin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 : S36 - S40
  • [9] Fast determination of polybrominated diphenyl ethers in human milk using gas chromatography-negative chemical ionization/mass spectrometry
    Liu Yinping
    Dai Peng
    Li Jingguang
    Zhang Lei
    Zhao Yunfeng
    Wu Yongning
    Zhu Lingyan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (06) : 687 - 691
  • [10] DETERMINATION OF ORGANOBROMINE COMPOUNDS IN WATER BY GAS CHROMATOGRAPHY-NEGATIVE ION CHEMICAL IONIZATION MASS-SPECTROMETRY
    KOIDA, K
    KOHNO, Y
    FUKUDA, Y
    SEKIGAWA, K
    YOSHIZAKI, S
    OKA, A
    NAKAYAMA, M
    EISEI KAGAKU-JAPANESE JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1983, 29 (06): : 352 - 356