Contralateral brachial plexus neuropathy after arthroscopic shoulder surgery

被引:9
作者
Pavlik, A
Ang, KC
Bell, SN
机构
[1] Natl Inst Sports Med, Dept Sports Surg, Budapest, Hungary
[2] Natl Univ Singapore Hosp, Dept Orthopaed Surg, Singapore 117548, Singapore
[3] Monash Univ, Dept Surg, Monash Med Ctr, Melbourne, Vic, Australia
关键词
shoulder arthroscopy; complication; patient positioning; brachial plexus lesion;
D O I
10.1053/jars.2002.32847
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This case report presents a neurologic complication that occurred after shoulder arthroscopic surgery on the contralateral arm. This brachial plexus palsy has been documented as a reversible C7-T1 lesion, which was the consequence of the patient's unknown cervical rib and the applied lateral position during the operation. In this case, the recovery was almost complete within 3 months postoperatively; however, one should take care to prevent these complications with an appropriate positioning of patients with an anatomic variant.
引用
收藏
页码:658 / 659
页数:2
相关论文
共 9 条
  • [1] Boardman N, 1999, CLIN ORTHOP RELAT R, P44
  • [2] COOPER DE, 1988, CLIN ORTHOP RELAT R, P33
  • [3] Klein A H, 1987, Arthroscopy, V3, P45, DOI 10.1016/S0749-8063(87)80009-9
  • [4] INJURY TO THE BRACHIAL-PLEXUS RESULTING FROM SHOULDER POSITIONING DURING LATISSIMUS DORSI FLAP PEDICLE DISSECTION
    LOGAN, AM
    BLACK, MJM
    [J]. BRITISH JOURNAL OF PLASTIC SURGERY, 1985, 38 (03): : 380 - 382
  • [5] Perlmutter GS, 1999, CLIN ORTHOP RELAT R, P28
  • [6] PITMAN M I, 1988, Arthroscopy, V4, P250, DOI 10.1016/S0749-8063(88)80039-2
  • [7] Segmuller H E, 1995, J Shoulder Elbow Surg, V4, P254, DOI 10.1016/S1058-2746(05)80017-5
  • [8] SMALL NC, 1986, ARTHROSCOPY, V2, P253
  • [9] SHOULDER ARTHROSCOPY AND NERVE INJURY - PITFALLS AND PREVENTION
    STANISH, WD
    PETERSON, DC
    [J]. ARTHROSCOPY, 1995, 11 (04): : 458 - 466