A Multi-Resolution Approach to Retrospectively-Gated Cardiac Micro-CT Reconstruction

被引:1
|
作者
Clark, D. P. [1 ]
Johnson, G. A. [1 ]
Badea, C. T. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Ctr In Vivo Microscopy, Durham, NC 27710 USA
来源
MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING | 2014年 / 9033卷
关键词
4D CT; micro-CT; iterative reconstruction; preclinical; retrospective gating; split Bregman method; RPCA; bilateral filtration; IMAGE-RECONSTRUCTION;
D O I
10.1117/12.2043044
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In preclinical research, micro-CT is commonly used to provide anatomical information; however, there is significant interest in using this technology to obtain functional information in cardiac studies. The fastest acquisition in 4D cardiac micro-CT imaging is achieved via retrospective gating, resulting in irregular angular projections after binning the projections into phases of the cardiac cycle. Under these conditions, analytical reconstruction algorithms, such as filtered back projection, suffer from streaking artifacts. Here, we propose a novel, multi-resolution, iterative reconstruction algorithm inspired by robust principal component analysis which prevents the introduction of streaking artifacts, while attempting to recover the highest temporal resolution supported by the projection data. The algorithm achieves these results through a unique combination of the split Bregman method and joint bilateral filtration. We illustrate the algorithm's performance using a contrast-enhanced, 2D slice through the MOBY mouse phantom and realistic projection acquisition and reconstruction parameters. Our results indicate that the algorithm is robust to under sampling levels of only 34 projections per cardiac phase and, therefore, has high potential in reducing both acquisition times and radiation dose. Another potential advantage of the multi-resolution scheme is the natural division of the reconstruction problem into a large number of independent sub-problems which can be solved in parallel. In future work, we will investigate the performance of this algorithm with retrospectively-gated, cardiac micro-CT data.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT
    Song, Jiayu
    Liu, Qing H.
    Johnson, G. Allan
    Badea, Cristian T.
    MEDICAL PHYSICS, 2007, 34 (11) : 4476 - 4483
  • [2] Rank-sparsity constrained, spectro-temporal reconstruction for retrospectively gated, dynamic CT
    Clark, D. P.
    Lee, C. L.
    Kirsch, D. G.
    Badea, C. T.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [3] Least-error projection sorting to optimize retrospectively gated cardiac micro-CT of free-breathing mice
    Armitage, Stephen E. J.
    Pollmann, Steven I.
    Detombe, Sarah A.
    Drangova, Maria
    MEDICAL PHYSICS, 2012, 39 (03) : 1452 - 1461
  • [4] Detection of the Optimal Reconstruction Window for Respiratory-Gated Micro-CT Imaging
    Ertel, D.
    Kyriakou, Y.
    Kalender, W. A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 87 - 90
  • [5] A MULTI-RESOLUTION APPROACH TO COMPLEXITY REDUCTION IN TOMOGRAPHIC RECONSTRUCTION
    Ma, Boxiao
    Zalmai, Nour
    Loeliger, Hans-Andrea
    2018 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2018, : 6518 - 6522
  • [6] Experimental studies on few-view reconstruction for high-resolution micro-CT
    Sen Sharma, Kriti
    Jin, Xin
    Holzner, Christian
    Narayanan, Shree
    Liu, Baodong
    Wang, Dong
    Agah, Masoud
    Wang, Libing
    Yu, Hengyong
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (01) : 25 - 42
  • [7] Spatial-resolution enhancement in micro-CT
    Pan, XC
    Yu, LF
    Kao, CM
    Pelizzari, C
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3244 - 3247
  • [8] Micro-CT with respiratory and cardiac gating
    Badea, C
    Hedlund, LW
    Johnson, GA
    MEDICAL PHYSICS, 2004, 31 (12) : 3324 - 3329
  • [9] A registration based approach for 4D cardiac micro-CT using combined prospective and retrospective gating
    Badea, Cristian T.
    Schreibmann, Eduard
    Fox, Tim
    MEDICAL PHYSICS, 2008, 35 (04) : 1170 - 1179
  • [10] Measurement of spatial resolution of the micro-CT system
    Rong Jun-Yan
    Fu Guo-Tao
    Wei Cun-Feng
    Sun Cui-Li
    Wei Long
    CHINESE PHYSICS C, 2010, 34 (03) : 412 - 416