Brachytherapy dose-volume histogram commissioning with multiple planning systems

被引:8
作者
Gossman, Michael S. [1 ,2 ]
Hancock, Samuel S. [3 ]
Kudchadker, Rajat J. [4 ]
Lundahl, Paul R. [5 ]
Cao, Minsong [6 ]
Melhus, Christopher S. [7 ]
机构
[1] Tri State Reg Canc Ctr, Dept Radiat Oncol, Ashland, KY 41101 USA
[2] Regulat Direct Med Phys, Flatwoods, KY USA
[3] Southeast Missouri Hosp, Dept Radiat Oncol, Cape Girardeau, MO USA
[4] UT MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX USA
[5] Riverside Methodist Hosp, Dept Radiat Oncol, Columbus, OH 43214 USA
[6] UCLA Sch Med, Dept Radiat Oncol, Los Angeles, CA USA
[7] Tufts Univ, Sch Med, Dept Radiat Oncol, Boston, MA 02111 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2014年 / 15卷 / 02期
关键词
brachytherapy; dose; DVH; histogram; volume; RADIATION-THERAPY COMMITTEE; CLINICAL IMPLEMENTATION; QUALITY-ASSURANCE; AAPM; DOSIMETRY; RECOMMENDATIONS; UPDATE;
D O I
10.1120/jacmp.v15i2.4620
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The first quality assurance process for validating dose-volume histogram data involving brachytherapy procedures in radiation therapy is presented. The process is demonstrated using both low dose-rate and high dose-rate radionuclide sources. A rectangular cuboid was contoured in five commercially available brachytherapy treatment planning systems. A single radioactive source commissioned for QA testing was positioned coplanar and concentric with one end. Using the brachytherapy dosimetry formalism defined in the AAPM Task Group 43 report series, calculations were performed to estimate dose deposition in partial volumes of the cuboid structure. The point-source approximation was used for a I-125 source and the line-source approximation was used for a Ir-192 source in simulated permanent and temporary implants, respectively. Hand-calculated, dose-volume results were compared to TPS-generated, dose-volume histogram (DVH) data to ascertain acceptance. The average disagreement observed between hand calculations and the treatment planning system DVH was less than 1% for the five treatment planning systems and less than 5% for 1 cm <= r <= 5 cm. A reproducible method for verifying the accuracy of volumetric statistics from a radiation therapy TPS can be employed. The process satisfies QA requirements for TPS commissioning, upgrading, and annual testing. We suggest that investigations be performed if the DVH % Vol(TPS) "actual variance" calculations differ by more than 5% at any specific radial distance with respect to % Vol(TG-43), or if the "average variance" DVH % Vol(TPS) calculations differ by more than 2% over all radial distances with respect to % Vol(TG-43).
引用
收藏
页码:110 / 120
页数:11
相关论文
共 50 条
  • [21] Are gamma passing rate and dose-volume histogram QA metrics correlated?
    Baran, Mateusz
    Tabor, Zbistaw
    Tulik, Monika
    Kabat, Damian
    Rzecki, Krzysztof
    Sosnicki, Tomasz
    Waligorski, Michael
    MEDICAL PHYSICS, 2021, 48 (09) : 4743 - 4753
  • [22] Deformable image registration for cervical cancer brachytherapy dose accumulation: Organ at risk dose-volume histogram parameter reproducibility and anatomic position stability
    Flower, E.
    Do, V.
    Sykes, J.
    Dempsey, C.
    Holloway, L.
    Sumrnerhayes, K.
    Thwaites, D. I.
    BRACHYTHERAPY, 2017, 16 (02) : 387 - 392
  • [23] Comprehensive methodology for commissioning modern 3D-image-based treatment planning systems for high dose rate gynaecological brachytherapy: A review
    Kanani, Abolfazl
    Owrangi, Amir M.
    Mosleh-Shirazi, Mohammad Amin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 21 - 29
  • [24] Impact of pre-brachytherapy magnetic resonance imaging on dose-volume histogram of locally advanced cervical cancer patients treated with radiotherapy including high-dose-rate brachytherapy
    Murofushi, Keiko Nemoto
    Ishida, Toshiki
    Baba, Keiichiro
    Kawakita, Kenji
    Sasaki, Tsukasa Saida
    Okumura, Toshiyuki
    Sato, Toyomi
    Sakurai, Hideyuki
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2021, 13 (01) : 32 - 38
  • [25] Duodenal complications in radiotherapy for bile duct cancer: A dose-volume histogram analysis
    Nakamura, Ryuji
    Kato, Kenichi
    Sone, Miyuki
    Oikawa, Hirobumi
    Ehara, Shigeru
    BRACHYTHERAPY, 2010, 9 (01) : 71 - 75
  • [26] Interstitial preoperative high-dose-rate brachytherapy for early stage cervical cancer: Dose-volume histogram parameters, pathologic response and early clinical outcome
    Hannoun-Levi, Jean-Michel
    Chand-Fouche, Marie-Eve
    Gautier, Mathieu
    Dejean, Catherine
    Marcy, Myriam
    Fouche, Yves
    BRACHYTHERAPY, 2013, 12 (02) : 148 - 155
  • [27] Dose-volume analysis of target volume and critical structures in computed tomography image-based multicatheter high-dose-rate interstitial brachytherapy for head and neck cancer
    Akiyama, Hironori
    Major, Tibor
    Polgar, Csaba
    Takacsi-Nagy, Zoltan
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2017, 9 (06) : 553 - 560
  • [28] Effect of Hyaluronate Acid Injection on Dose-Volume Parameters in Brachytherapy for Cervical Cancer
    Kobayashi, Rei
    Murakami, Naoya
    Chiba, Takahito
    Okuma, Kae
    Inaba, Koji
    Takahashi, Kana
    Kaneda, Tomoya
    Kashihara, Tairo
    Takahashi, Ayaka
    Shimizu, Yuri
    Nakayama, Yuko
    Kato, Tomoyasu
    Ito, Yoshinori
    Igaki, Hiroshi
    ADVANCES IN RADIATION ONCOLOGY, 2022, 7 (03)
  • [29] Asymmetric dose-volume optimization with smoothness control for rotating-shield brachytherapy
    Liu, Yunlong
    Flynn, Ryan T.
    Kim, Yusung
    Wu, Xiaodong
    MEDICAL PHYSICS, 2014, 41 (11)
  • [30] Comp Plan: A computer program to generate dose and radiobiological metrics from dose-volume histogram files
    Holloway, Lois Charlotte
    Miller, Julie-Anne
    Kumar, Shivani
    Whelan, Brendan M.
    Vinod, Shalini K.
    MEDICAL DOSIMETRY, 2012, 37 (03) : 305 - 309