Diagnostic performance of multifocal photopic negative response, pattern electroretinogram and optical coherence tomography in glaucoma

被引:12
作者
Al-Nosairy, Khaldoon O. [1 ]
Thieme, Hagen [1 ]
Hoffmann, Michael B. [1 ,2 ]
机构
[1] Otto von Guericke Univ, Dept Ophthalmol, Leipziger Str 44, D-39120 Magdeburg, Germany
[2] Ctr Behav Brain Sci, Magdeburg, Germany
基金
欧盟地平线“2020”;
关键词
Multifocal; ERG; Photopic negative response; Glaucoma; Pattern electroretinogram; Retinal ganglion cells; FIBER LAYER THICKNESS; OPEN-ANGLE GLAUCOMA; VISUAL-FIELD; TOPOGRAPHY; EYES; ERG;
D O I
10.1016/j.exer.2020.108242
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The photopic negative response of the electroretinogram reflects retinal ganglion cell function and consequently aids diagnosis of optic nerve diseases including glaucoma. In this study, we assessed the efficacy of stimulation parameters for electroretinographic recordings of the multifocal photopic negative response (mfPhNR) for the detection of glaucoma and compared the diagnostic accuracy of electrophysiological, structural and functional measures of glaucoma. We compared the diagnostic performance of the mfPhNR for 6 different stimulation rates in a cohort of 24 controls, 10 glaucoma suspects (GLA(S)) and 16 glaucoma participants (GLA(G)). A cross-modal comparison of the mfPhNR/b wave ratio was performed with the pattern electroretinogram (PERG), and the peripapillary retinal nerve fiber layer (pRNFL) thickness. These analyses were based on area under curves (AUC) obtained from receiver-operating-characteristics (ROC) and step-wise regression analyses. We found that compared to the other mfPhNR-conditions, the PhNR/b-wave ratio for the fastest stimulation condition had the highest AUC for GLA(S) (0.84, P = 0.008, 95%CI: 0.71- 0.98), while the other modalities, i.e., PERG-amplitude and pRNFL had AUCs of 0.78 (P= 0.039), and 0.74 (P < 0.05), respectively. For GLA(G), the respective AUCs were 0.78 (P= 0.004), 0.85 (P< 0.001) and 0.87 (P< 0.001). pRNFL was the significant predictor for both mfPhNR/b-wave ratio [t (48) = 4, P = 0.0002] and for PERG amplitude [t (48) = 3.4, P = 0.001]. In conclusion, fast mfPhNR protocols outperform other multifocal PhNR protocols in the identification of glaucomatous damage especially for GLA(S) and thus aid the early detection of glaucoma, indicating its value as a surrogate marker of early stage ganglion cell dysfunction.
引用
收藏
页数:11
相关论文
共 41 条
[1]  
AlNosairy K.O., 2020, BR J OPHTHALMOL, V3161, P36
[2]  
[Anonymous], 2001, INVEST OPHTH VIS SCI
[3]   Different effect of dioptric defocus vs. light scatter on the Pattern Electroretinogram (PERG) [J].
Bach, M ;
Mathieu, M .
DOCUMENTA OPHTHALMOLOGICA, 2004, 108 (01) :99-106
[4]  
Bach M., 2006, PRINCIPLES PRACTICE, V2nd, P185
[5]  
Bach M., 2000, VISUAL EVOKED POTENT
[6]   Update on the pattern electroretinogram in glaucoma [J].
Bach, Michael ;
Hoffmann, Michael B. .
OPTOMETRY AND VISION SCIENCE, 2008, 85 (06) :386-395
[7]   Pattern ERG as an early glaucoma indicator in ocular hypertension: A long-term, prospective study [J].
Bach, Michael ;
Unsoeld, Anke S. ;
Philippin, Heiko ;
Staubach, Flemming ;
Maier, Philip ;
Walter, Hans S. ;
Bomer, Thomas G. ;
Funk, Jens .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (11) :4881-4887
[8]   Pattern Electroretinogram in Glaucoma Suspects: New Findings from a Longitudinal Study [J].
Bode, Sebastian F. N. ;
Jehle, Thomas ;
Bach, Michael .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (07) :4300-4306
[9]   Practical recommendations for measuring rates of visual field change in glaucoma [J].
Chauhan, B. C. ;
Garway-Heath, D. F. ;
Goni, F. J. ;
Rossetti, L. ;
Bengtsson, B. ;
Viswanathan, A. C. ;
Heijl, A. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (04) :569-573
[10]  
Elgohary A.M, 2019, EUR J OPHTHALMOL