Compositional heterogeneity in partially hydrolysed poly(vinyl alcohol) by reversed phase liquid chromatography

被引:14
作者
Dawkins, JV [1 ]
Nicholson, TA
Handley, AJ
Meehan, E
Nevin, A
Shaw, PL
机构
[1] Univ Loughborough, Dept Chem, Loughborough LE11 3TU, Leics, England
[2] ICI Chem & Polymers Ltd, Runcorn WA7 4QD, Cheshire, England
[3] Polymer Labs Ltd, Church Stretton SY6 6AX, Shrops, England
[4] European Vinyls Corp Ltd, Res & Tech Serv, Runcorn WA7 4AD, Cheshire, England
[5] Harlow Chem Co Ltd, Harco, Harlow CM20 2AH, Essex, England
基金
英国工程与自然科学研究理事会;
关键词
poly(vinyl alcohol); degree of hydrolysis; high performance liquid chromatography;
D O I
10.1016/S0032-3861(98)00863-5
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Reversed phase high performance liquid chromatography (HPLC) was employed to elucidate the composition distribution of partially hydrolysed samples of poly(vinyl alcohol) (PVOH), demonstrating that elution across a chromatogram proceeded from higher to lower degree of hydrolysis (DoH). Fractions isolated by preparative HPLC fractionation and characterised by H-1 nuclear magnetic resonance spectroscopy (NMR) were used as HPLC standards to construct a calibration curve of retention time versus DoH, allowing for DoH determination of any PVOH sample once its chromatogram was available. Plots of cumulative and differential distributions as a function of DoH were determined, allowing for comparisons of samples having average DoH in the range 70-90 mol%. A second set of fractions originating from a parent polymer having different molar mass was also isolated to confirm that calibration was not influenced by molar mass or size exclusion effects. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:7331 / 7339
页数:9
相关论文
共 27 条
[1]   COUPLED GPC-HPLC - CO-POLYMER COMPOSITION AND AXIAL-DISPERSION CHARACTERIZATION [J].
BALKE, ST ;
PATEL, RD .
JOURNAL OF POLYMER SCIENCE PART C-POLYMER LETTERS, 1980, 18 (06) :453-456
[2]   CALIBRATION PROCEDURES FOR BRANCHED POLYVINYL ACETATE) IN SIZE EXCLUSION CHROMATOGRAPHY [J].
COLEMAN, TA ;
DAWKINS, JV .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1986, 9 (06) :1191-1215
[3]   HIGH-PERFORMANCE COLUMN ADSORPTION CHROMATOGRAPHY OF RANDOM CO-POLYMERS STYRENE-ACRYLICS [J].
DANIELEWICZ, M ;
KUBIN, M .
JOURNAL OF APPLIED POLYMER SCIENCE, 1981, 26 (03) :951-956
[4]   COUPLED COLUMN CHROMATOGRAPHY FOR COPOLYMER CHARACTERIZATION [J].
DAWKINS, JV ;
MONTENEGRO, AMC .
BRITISH POLYMER JOURNAL, 1989, 21 (01) :31-36
[5]   DETERMINATION OF THE MOLECULAR-WEIGHT AND COMPOSITIONAL HETEROGENEITY OF BLOCK COPOLYMERS USING COMBINED GEL-PERMEATION CHROMATOGRAPHY AND LOW-ANGLE LASER-LIGHT SCATTERING [J].
DUMELOW, T ;
HOLDING, SR ;
MAISEY, LJ ;
DAWKINS, JV .
POLYMER, 1986, 27 (08) :1170-1176
[6]  
FUCHS O, 1967, POLYMER FRACTIONATIO, P341
[7]  
GLOCKNER G, 1986, J CHROMATOGR LIB, V34
[8]  
Glockner G., 1991, Gradient HPLC of Copolymers and Chromatographic Cross-Fractionation
[9]  
KARGER BL, 1978, ANAL CHEM, V50, pA048, DOI 10.1021/ac50034a001
[10]   PREPARATIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON A UNIQUE HIGH-SPEED MACROPOROUS RESIN [J].
LLOYD, LL ;
WARNER, FP .
JOURNAL OF CHROMATOGRAPHY, 1990, 512 :365-376