Testing of mechanical ventilators and infant incubators in healthcare institutions

被引:31
作者
Badnjevic, Almir [1 ,2 ,3 ]
Gurbeta, Lejla [1 ,2 ]
Jimenez, Elvira Ruiz [4 ]
Iadanza, Ernesto [5 ]
机构
[1] Verlab Ltd, Sarajevo, Bosnia & Herceg
[2] Int Burch Univ, Fac Engn & IT, Ilidza, Bosnia & Herceg
[3] Univ Sarajevo, Fac Elect Engn, Sarajevo, Bosnia & Herceg
[4] Univ Dublin, Trinity Coll Dublin, Dublin, Ireland
[5] Univ Florence, Dept Informat Engn, Florence, Italy
关键词
Health technology management; clinical engineering; testing; output parameters; mechanical ventilators; infant incubators; safety; standards; healthcare; CLASSIFICATION; DIAGNOSIS; SAFETY; SYSTEM;
D O I
10.3233/THC-161269
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The medical device industry has grown rapidly and incessantly over the past century. The sophistication and complexity of the designed instrumentation is nowadays rising and, with it, has also increased the need to develop some better, more effective and efficient maintenance processes, as part of the safety and performance requirements. This paper presents the results of performance tests conducted on 50 mechanical ventilators and 50 infant incubators used in various public healthcare institutions. Testing was conducted in accordance to safety and performance requirements stated in relevant international standards, directives and legal metrology policies. Testing of output parameters for mechanical ventilators was performed in 4 measuring points while testing of output parameters for infant incubators was performed in 7 measuring points for each infant incubator. As performance criteria, relative error of output parameters for mechanical ventilators and absolute error of output parameters for infant incubators was calculated. The ranges of permissible error, for both groups of devices, are regulated by the Rules on Metrological and Technical Requirements published in the Official Gazette of Bosnia and Herzegovina No. 75/14, which are defined based on international recommendations, standards and guidelines. All ventilators and incubators were tested by etalons calibrated in an ISO 17025 accredited laboratory, which provides compliance to international standards for all measured parameters. The results show that 30% of the tested medical devices are not operating properly and should be serviced, recalibrated and/or removed from daily application.
引用
收藏
页码:237 / 250
页数:14
相关论文
共 50 条
[1]  
Alcantara Holanda M., XLUNG PLATFORM TEACH
[2]   The Impact of Recycled Neonatal Incubators in Nigeria: A 6-Year Follow-Up Study [J].
Amadi, Hippolite Onyejiaka ;
Azubuike, Jonathan C. ;
Etawo, Uriah S. ;
Offiong, Uduak R. ;
Ezeaka, Chinyere ;
Olateju, Eyinade ;
Adimora, Gilbert N. ;
Osibogun, Akin ;
Ibeziako, Ngozi ;
Iroha, Edna O. ;
Dutse, Abdulhameed I. ;
Chukwu, Christian O. ;
Okpere, Eugene E. ;
Kawuwa, Mohammed B. ;
El-Nafaty, Aliyu U. ;
Kuranga, Sulyman A. ;
Mokuolu, Olugbenga Ayodeji .
INTERNATIONAL JOURNAL OF PEDIATRICS, 2010, 2010
[3]  
[Anonymous], 60601 IEC
[4]  
[Anonymous], 80601212 IEC
[5]  
[Anonymous], 2015, EQ892015 ANSIAAMI
[6]  
[Anonymous], 2011, WHO MED DEV TECHN SE
[7]  
[Anonymous], 1998, 142532 ISOTR
[8]  
[Anonymous], 60601219 IEC
[9]   The infant incubator in the neonatal intensive care unit: unresolved issues and future developments [J].
Antonucci, Roberto ;
Porcella, Annalisa ;
Fanos, Vassilios .
JOURNAL OF PERINATAL MEDICINE, 2009, 37 (06) :587-598
[10]  
Badnjevic A, 2015, Folia Medica, V50, P43