Test-retest reliability of electrical impedance myography in hamstrings of healthy young men

被引:9
作者
Honorato, Renee de Caldas [1 ,2 ]
Marreiros Ferraz, Alex Soares [3 ]
Kassiano, Witalo [4 ]
Carvalho, Denise Pires [5 ]
Ceccatto, Vania Marilande [2 ,6 ]
机构
[1] Para State Univ, Sports Dept, Belem, Para, Brazil
[2] Univ Estadual Ceara, Postgrad Program Biotechnol, Northeast Biotechnol Network, Fortaleza, Ceara, Brazil
[3] Univ Fed Ceara, Inst Phys Educ & Sports, Biotechnol & Exercise Biol Res Lab, Fortaleza, Ceara, Brazil
[4] Univ Estadual Londrina, Phys Educ & Sport Ctr, Metab Nutr & Exercise Lab, Londrina, Parana, Brazil
[5] Univ Fed Rio de Janeiro, Inst Biophys Carlos Chagas Filho, Endocrine Physiol Doris Rosenthal Res Lab, Rio De Janeiro, Brazil
[6] Univ Estadual Ceara, Super Inst Biomed Sci, Biochem & Gene Express Res Lab, Fortaleza, Ceara, Brazil
关键词
Bioelectrical impedance spectroscopy; Posterior thigh; Phase angle; Resistance; Muscle;
D O I
10.1016/j.jelekin.2020.102511
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Several techniques are available to assess muscle tissue status, including electrical impedance myography (EIM). Despite being used in the assessment of neuromuscular status in injury and response to exercise, reliability data for hamstrings muscles are limited. Therefore, this study aimed to determine the test-retest reliability of EIM components on hamstrings. Twenty-one healthy males (25.3 +/- 3.4 years; 173 +/- 6.7 cm; and 79.7 +/- 15.9 kg) volunteered for this study. Subjects completed two visits, separated by seven days to collect EIM components (resistance, reactance, impedance, and phase angle) in the longitudinal and transversal axis of hamstrings in both thighs, using a bioimpedance device and Ag/AgCL adhesive contact electrodes. The electrode arrangement was in the muscular belly, half the distance between origin and insertion of the hamstrings. Reliability was determined by the intraclass correlation coefficient (ICC), minimal detectable change (MDC), and Bland-Altman plots. We observed high to excellent reliability (ICC > 0.85) between all EIM components, except for reactance with MDC ranged from 2.0 to 10.8 and the mean bias in Bland-Altman plots ranged from -0.02 to 2.48 (95% limits of agreement from-9.98 to 11.20). From our findings, the hamstrings assessment using EIM technique is reliable to assess muscle tissue; therefore, it enables the evaluation of changes/adaptations in clinical and applied contexts.
引用
收藏
页数:5
相关论文
共 22 条
  • [1] Bioelectrical impedance phase angle in sport: a systematic review
    Di Vincenzo, Olivia
    Marra, Maurizio
    Scalfi, Luca
    [J]. JOURNAL OF THE INTERNATIONAL SOCIETY OF SPORTS NUTRITION, 2019, 16 (01) : 1
  • [2] Francavilla VC, 2015, MED SPORT, V68, P323
  • [3] Biceps tissue bioimpedance changes from isotonic exercise-induced fatigue at different intensities
    Fu, Bo
    Freeborn, Todd J.
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (02):
  • [4] A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research
    Koo, Terry K.
    Li, Mae Y.
    [J]. JOURNAL OF CHIROPRACTIC MEDICINE, 2016, 15 (02) : 155 - 163
  • [5] Bioelectrical impedance analysis principles and methods
    Kyle, UG
    Bosaeus, I
    De Lorenzo, AD
    Deurenberg, P
    Elia, M
    Gómez, JM
    Heitmann, BL
    Kent-Smith, L
    Melchior, JC
    Pirlich, M
    Scharfetter, H
    Schols, AMWJ
    Pichard, C
    [J]. CLINICAL NUTRITION, 2004, 23 (05) : 1226 - 1243
  • [6] Li L., 2016, SENSORS BASEL, V16
  • [7] The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses
    Li, Le
    Li, Xiaoyan
    Hu, Huijing
    Shin, Henry
    Zhou, Ping
    [J]. PLOS ONE, 2016, 11 (05):
  • [8] Intra- and inter-rater reliability of electrical impedance myography using adhesive electrodes in healthy volunteers
    Martinez-Gonzalez, Mariano
    Montilla-Herrador, Joaquina
    Garcia-Vidal, Jose A.
    Escolar-Reina, Pilar
    Gacto-Sanchez, Mariano
    Medina-Mirapeix, Francesc
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2020, 55
  • [9] Cell integrity indicators assessed by bioelectrical impedance: A systematic review of studies involving athletes
    Martins, Priscila Custodio
    Moraes, Mikael Seabra
    Santos Silva, Diego Augusto
    [J]. JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2020, 24 (01) : 154 - 164
  • [10] Effects of muscle injury severity on localized bioimpedance measurements
    Nescolarde, L.
    Yanguas, J.
    Lukaski, H.
    Alomar, X.
    Rosell-Ferrer, J.
    Rodas, G.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (01) : 27 - 42