Direct measurement of intracranial pressure in adult horses

被引:19
作者
Brosnan, RJ [1 ]
LeCouteur, RA [1 ]
Steffey, EP [1 ]
Imai, A [1 ]
Kortz, GD [1 ]
机构
[1] Univ Calif Davis, Sch Vet Med, Dept Surg & Radiol Sci, Davis, CA 95616 USA
关键词
D O I
10.2460/ajvr.2002.63.1252
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To develop a method for surgical placement of a commercial microsensor intracranial pressure (ICP) transducer and to characterize normal ICP and cerebral perfusion pressures (CPP) in conscious adult horses. Animals-6 healthy castrated male adult horses (1 Holsteiner, 1 Quarter Horse, and 4 Thoroughbreds). Procedure-Anesthesia was induced and maintained by use of isoflurane as the sole agent. Catheters were inserted percutaneously into the jugular vein and carotid artery. A microsensor ICP transducer was inserted in the subarachnoid space by means of right parietal craniotomy. The burr hole was then sealed with bone wax, the surgical incision was sutured, and the transducer was secured in place. Measurements were collected 1 hour after horses were able to stand during recovery from anesthesia. Results-Mean +/- SD values for ICP and CPP were 2 +/- 4 and 102 +/- 26 mm Hg, respectively. Conclusions and Clinical Relevance-This report describes a relatively facile technique for obtaining direct and accurate ICP measurements for adult horses. The ICP values obtained in this study are within reference ranges established for other species and provide a point of reference for the diagnosis of abnormal ICP in adult horses.
引用
收藏
页码:1252 / 1256
页数:5
相关论文
共 30 条
  • [11] Jiang J, 1997, UNDERSEA HYPERBAR M, V24, P39
  • [12] KORTZ GD, 1995, AM J VET RES, V56, P1351
  • [13] LEE KR, 1996, NEUROLOGICAL SURG, P496
  • [14] Accuracy of a miniature intracranial pressure monitor, its function during magnetic resonance scanning, and assessment of image artifact generation
    Macmillan, CSA
    Wild, JM
    Andrews, PJD
    Marshall, I
    Armitage, PA
    Wardlaw, JM
    Easton, VJ
    Cannon, J
    [J]. NEUROSURGERY, 1999, 45 (01) : 188 - 192
  • [15] MEASUREMENT OF INTRACRANIAL-PRESSURE IN THE UNANESTHETIZED RABBIT
    MALKINSON, TJ
    VEALE, WL
    COOPER, KE
    [J]. BRAIN RESEARCH BULLETIN, 1978, 3 (06) : 635 - 638
  • [16] Morgalla MH, 1999, J MED ENG TECHNOL, V23, P144, DOI 10.1080/030919099294195
  • [17] ICP measurement accuracy: the effect of temperature drift. Design of a laboratory test for assessment of ICP transducers
    Morgalla, MH
    Mettenleiter, H
    Katzenberger, T
    [J]. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1999, 23 (01) : 10 - 14
  • [18] MORROW BA, 1990, AM J PHYSIOL, V258, pR1170, DOI 10.1152/ajpregu.1990.258.5.R1170
  • [19] Cerebral perfusion pressure monitoring alert!
    Nates, JL
    Niggemeyer, LE
    Anderson, MB
    Tuxen, DV
    [J]. CRITICAL CARE MEDICINE, 1997, 25 (05) : 895 - 896
  • [20] NORTH B, 1990, RAISED INTRACRANIAL, P32