Development of a Wearable Device for Motion Capturing Based on Magnetic and Inertial Measurement Units

被引:18
作者
Fang, Bin [1 ]
Sun, Fuchun [1 ]
Liu, Huaping [1 ]
Guo, Di [1 ]
机构
[1] Tsinghua Univ, Dept Comp Sci & Technol, Tsinghua Natl Lab Informat Sci & Technol, State Key Lab Intelligent Technol & Syst, Beijing 100083, Peoples R China
基金
中国国家自然科学基金; 美国国家科学基金会;
关键词
SENSORS; GLOVE; ACCELEROMETER;
D O I
10.1155/2017/7594763
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
This paper presents a novel wearable device for gesture capturing based on inertial and magnetic measurement units that are made up of micromachined gyroscopes, accelerometers, and magnetometers. The low-cost inertial and magnetic measurement unit is compact and small enough to wear and there are altogether thirty-six units integrated in the device. The device is composed of two symmetric parts, and either the right part or the left one contains eighteen units covering all the segments of the arm, palm, and fingers. The offline calibration and online calibration are proposed to improve the accuracy of sensors. Multiple quaternion-based extended Kalman filters are designed to estimate the absolute orientations, and kinematic models of the arm-hand are considered to determine the relative orientations. Furthermore, position algorithm is deduced to compute the positions of corresponding joint. Finally, several experiments are implemented to verify the effectiveness of the proposed wearable device.
引用
收藏
页数:11
相关论文
共 29 条
[1]  
[Anonymous], 2015, MPU 9250 9 AX MEMS M
[2]   Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements [J].
Arkenbout, Ewout A. ;
de Winter, Joost C. F. ;
Breedveld, Paul .
SENSORS, 2015, 15 (12) :31644-31671
[3]   Non-Linear Symmetry-Preserving Observers on Lie Groups [J].
Bonnabel, Silvere ;
Martin, Philippe ;
Rouchon, Pierre .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2009, 54 (07) :1709-1713
[4]  
Cavallo Filippo, 2013, IEEE Int Conf Rehabil Robot, V2013, P6650466, DOI 10.1109/ICORR.2013.6650466
[5]   Body Area Networks: A Survey [J].
Chen, Min ;
Gonzalez, Sergio ;
Vasilakos, Athanasios ;
Cao, Huasong ;
Leung, Victor C. M. .
MOBILE NETWORKS & APPLICATIONS, 2011, 16 (02) :171-193
[6]   Two-step optimal filter design for the low-cost attitude and heading reference systems [J].
Chou, Wusheng ;
Fang, Bin ;
Ding, Li ;
Ma, Xin ;
Guo, Xiaoqi .
IET SCIENCE MEASUREMENT & TECHNOLOGY, 2013, 7 (04) :240-248
[7]   A survey of glove-based systems and their applications [J].
Dipietro, Laura ;
Sabatini, Angelo M. ;
Dario, Paolo .
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS PART C-APPLICATIONS AND REVIEWS, 2008, 38 (04) :461-482
[8]   A Novel Calibration Method of Magnetic Compass Based on Ellipsoid Fitting [J].
Fang, Jiancheng ;
Sun, Hongwei ;
Cao, Juanjuan ;
Zhang, Xiao ;
Tao, Ye .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (06) :2053-2061
[9]   Development and evaluation of a low-cost sensor glove for assessment of human finger movements in neurophysiological settings [J].
Gentner, Reinhard ;
Classen, Joseph .
JOURNAL OF NEUROSCIENCE METHODS, 2009, 178 (01) :138-147
[10]  
Hamel T, 2006, IEEE INT CONF ROBOT, P2170