Early failure of precoated femoral components in primary total hip arthroplasty

被引:68
|
作者
Ong, A
Wong, KL
Lai, M
Garino, JP
Steinberg, ME
机构
[1] Hand Ctr San Antonio, San Antonio, TX 78240 USA
[2] Hosp Univ Penn, Dept Orthopaed Surg, Philadelphia, PA 19104 USA
来源
关键词
D O I
10.2106/00004623-200205000-00014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: In an effort to decrease the rate of aseptic loosening, certain cemented femoral components were designed to have a roughened or textured surface with a methylmethacrylate precoating. Reports differ as to whether this step has increased or decreased the rate of failure. This study was designed to evaluate this issue. Methods: Five hundred and fourteen hips treated with a cemented Harris Precoat stem (Zimmer, Warsaw, Indiana) were evaluated clinically and radiographically and compared with 254 hips treated with an uncoated Harris Design-2 stem (Howmedica, East Rutherford, New Jersey). Prostheses that had been removed at revision were examined. The cementing and surgical techniques were identical and the population demographics were similar for these two groups. Results: The mean durations of follow-up were 8.4 and 13.5 years for the Precoat and uncoated Design-2 stems, respectively. At those times, at least forty-nine (9.5%) of the 514 Precoat components and at least ten (3.9%) of the 254 uncoated Design-2 stems had failed (p = 0.006). Five Precoat stems fractured, and no uncoated Design-2 stems fractured. Component failure was associated with use in young, active, heavy men with a diagnosis of avascular necrosis and generally with the use of smaller components. The cementing technique was satisfactory in the majority of the patients, and there were no qualitative differences in cementing technique between the hips that failed and those that did not. The mechanisms of failure of the Precoat prostheses included bone-cement loosening, focal osteolysis, stem fracture, and prosthesis-cement debonding. Fractures of smaller components occurred as a result of fatigue failure and were associated with good distal fixation but proximal stem loosening. Conclusions: The rate of failure of roughened, precoated, cemented femoral components was considerably higher and occurred earlier than that of femoral components that were neither textured nor precoated with methylmethacrylate. Younger patients with avascular necrosis had a higher risk of failure; however, this factor alone did not completely explain the differences in outcome between these two components. The causes of aseptic loosening are multifactorial and may be related to component design and size as well as to precoating and surface finish.
引用
收藏
页码:786 / 792
页数:7
相关论文
共 50 条
  • [31] Catastrophic failure of modular zirconia-ceramic femoral head components after total hip arthroplasty
    Hummer, CD
    Rothman, RH
    Hozack, WJ
    JOURNAL OF ARTHROPLASTY, 1995, 10 (06): : 848 - 850
  • [32] MECHANISMS OF FAILURE OF THE FEMORAL AND TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY
    WINDSOR, RE
    SCUDERI, GR
    MORAN, MC
    INSALL, JN
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (248) : 15 - 20
  • [33] Cemented revision of failed uncemented femoral components of total hip arthroplasty
    Davis, CM
    Berry, DJ
    Harmsen, WS
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (07): : 1264 - 1269
  • [34] Total hip arthroplasty - Concerns with extensively porous coated femoral components
    McAuley, JP
    Culpepper, WJ
    Engh, CA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (355) : 182 - 188
  • [35] STRATEGIES FOR IMPROVING FIXATION OF FEMORAL COMPONENTS IN TOTAL HIP-ARTHROPLASTY
    POSS, R
    WALKER, P
    SPECTOR, M
    REILLY, DT
    ROBERTSON, DD
    SLEDGE, CB
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (235) : 181 - 194
  • [36] Age and Sex Influence the Use of Modular Femoral Components in Total Hip Arthroplasty Performed for Primary Osteoarthritis
    Castagnini, Francesco
    Bordini, Barbara
    Cosentino, Monica
    Di Liddo, Michele
    Tella, Giuseppe
    Masetti, Claudio
    Traina, Francesco
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (03)
  • [37] Failure of total hip arthroplasty with a precoated prosthesis - 4- to 11-year results
    Dowd, JE
    Cha, CW
    Trakru, S
    Kim, SY
    Yang, CH
    Rubash, HE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (355) : 123 - 136
  • [38] A Conversion Total Hip Arthroplasty Is Not a Primary Total Hip Arthroplasty
    Raiford, Mattie E.
    Barra, Matthew F.
    Myers, Thomas G.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2019, 29 (03)
  • [39] FAILURE OF CEMENTLESS FIXATION OF THE FEMORAL COMPONENT IN TOTAL HIP-ARTHROPLASTY
    OTANI, T
    WHITESIDE, LA
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1992, 23 (02) : 335 - 346
  • [40] A calcar collar is protective against early periprosthetic femoral fracture around cementless femoral components in primary total hip arthroplasty A REGISTRY STUDY WITH BIOMECHANICAL VALIDATION
    Lamb, J. N.
    Baetz, J.
    Messer-Hannemann, P.
    Adekanmbi, I
    van Duren, B. H.
    Redmond, A.
    West, R. M.
    Morlock, M. M.
    Pandit, H. G.
    BONE & JOINT JOURNAL, 2019, 101B (07): : 779 - 786