Early failure of precoated femoral components in primary total hip arthroplasty

被引:68
|
作者
Ong, A
Wong, KL
Lai, M
Garino, JP
Steinberg, ME
机构
[1] Hand Ctr San Antonio, San Antonio, TX 78240 USA
[2] Hosp Univ Penn, Dept Orthopaed Surg, Philadelphia, PA 19104 USA
来源
关键词
D O I
10.2106/00004623-200205000-00014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: In an effort to decrease the rate of aseptic loosening, certain cemented femoral components were designed to have a roughened or textured surface with a methylmethacrylate precoating. Reports differ as to whether this step has increased or decreased the rate of failure. This study was designed to evaluate this issue. Methods: Five hundred and fourteen hips treated with a cemented Harris Precoat stem (Zimmer, Warsaw, Indiana) were evaluated clinically and radiographically and compared with 254 hips treated with an uncoated Harris Design-2 stem (Howmedica, East Rutherford, New Jersey). Prostheses that had been removed at revision were examined. The cementing and surgical techniques were identical and the population demographics were similar for these two groups. Results: The mean durations of follow-up were 8.4 and 13.5 years for the Precoat and uncoated Design-2 stems, respectively. At those times, at least forty-nine (9.5%) of the 514 Precoat components and at least ten (3.9%) of the 254 uncoated Design-2 stems had failed (p = 0.006). Five Precoat stems fractured, and no uncoated Design-2 stems fractured. Component failure was associated with use in young, active, heavy men with a diagnosis of avascular necrosis and generally with the use of smaller components. The cementing technique was satisfactory in the majority of the patients, and there were no qualitative differences in cementing technique between the hips that failed and those that did not. The mechanisms of failure of the Precoat prostheses included bone-cement loosening, focal osteolysis, stem fracture, and prosthesis-cement debonding. Fractures of smaller components occurred as a result of fatigue failure and were associated with good distal fixation but proximal stem loosening. Conclusions: The rate of failure of roughened, precoated, cemented femoral components was considerably higher and occurred earlier than that of femoral components that were neither textured nor precoated with methylmethacrylate. Younger patients with avascular necrosis had a higher risk of failure; however, this factor alone did not completely explain the differences in outcome between these two components. The causes of aseptic loosening are multifactorial and may be related to component design and size as well as to precoating and surface finish.
引用
收藏
页码:786 / 792
页数:7
相关论文
共 50 条
  • [21] EARLY ASEPTIC LOOSENING OF UNCEMENTED FEMORAL COMPONENTS IN PRIMARY TOTAL HIP-REPLACEMENT - A REVIEW BASED ON THE NORWEGIAN ARTHROPLASTY REGISTER
    HAVELIN, LI
    ESPEHAUG, B
    VOLLSET, SE
    ENGESAETER, LB
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (01): : 11 - 17
  • [22] Primary Total Hip Arthroplasty for Displaced Femoral Neck Fracture
    Watson, David
    Bostrom, Mathias
    Salvati, Eduardo
    Walcott-Sapp, Sarah
    Westrich, Geoffrey
    ORTHOPEDICS, 2008, 31 (10) : 990 - 990
  • [23] Dislocations and the femoral head size in primary total hip arthroplasty
    Hedlundh, U
    Ahnfelt, L
    Hybbinette, CH
    Wallinder, L
    Weckstrom, J
    Fredin, H
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (333) : 226 - 233
  • [24] Intraoperative Measurement of Femoral Offset in Primary Total Hip Arthroplasty
    Iqbal, Shoaib
    Datir, Sandeep
    TECHNIQUES IN ORTHOPAEDICS, 2015, 30 (04) : E15 - E16
  • [25] Femoral head diameter considerations for primary total hip arthroplasty
    Girard, J.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (01) : S25 - S29
  • [26] Hydroxyapatite coating on the femoral stem in primary total hip arthroplasty
    Bierbaum, BE
    Zeegen, EN
    Dayton, MR
    ORTHOPEDICS, 2003, 26 (09) : 913 - 914
  • [27] Primary total hip arthroplasty with a retained intramedullary femoral nail
    Goosen, Jon H. M.
    Van Hellemondt, Gijs G.
    ACTA ORTHOPAEDICA BELGICA, 2013, 79 (01): : 114 - 116
  • [28] Isoelastic femoral component in primary cementless total hip arthroplasty
    Salaman M. Ali
    A. Kumar
    International Orthopaedics, 2002, 26 : 243 - 246
  • [29] Isoelastic femoral component in primary cementless total hip arthroplasty
    Ali, MS
    Kumar, A
    INTERNATIONAL ORTHOPAEDICS, 2002, 26 (04) : 243 - 246
  • [30] Precoated femoral component in total hip arthroplasty - Results of 5-to 9-year followup
    Brown, EC
    Lachiewicz, PF
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (364) : 153 - 159