Comparison of extraocular and intraocular pressure transducers for measurement of transient intraocular pressure fluctuations using continuous wireless telemetry

被引:4
作者
Jasien, Jessica, V [1 ]
Zohner, Ye Emma [2 ]
Asif, Sonia Kuhn [3 ]
Rhodes, Lindsay A. [3 ]
Samuels, Brian C. [3 ]
Girkin, Christopher A. [3 ]
Morris, Jeffrey S. [4 ]
Downs, J. Crawford [3 ]
机构
[1] Univ Alabama Birmingham, Sch Optometry, Vis Sci Grad Program, Birmingham, AL 35294 USA
[2] Rice Univ, Houston, TX USA
[3] Univ Alabama Birmingham, Sch Med, Dept Ophthalmol & Visual Sci, VH 390B,1670 Univ Blvd, Birmingham, AL 35294 USA
[4] Univ Penn, Perelman Sch Med, Philadelphia, PA 19104 USA
关键词
LAMINA-CRIBROSA; RISK-FACTOR; IOP; MAGNITUDE; PROGRESSION; FREQUENCY; SENSOR;
D O I
10.1038/s41598-020-77880-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The optimal approach for continuous measurement of intraocular pressure (IOP), including pressure transducer location and measurement frequency, is currently unknown. This study assessed the capability of extraocular (EO) and intraocular (IO) pressure transducers, using different IOP sampling rates and duty cycles, to characterize IOP dynamics. Transient IOP fluctuations were measured and quantified in 7 eyes of 4 male rhesus macaques (NHPs) using the Konigsberg EO system (continuous at 500 Hz), 12 eyes of 8 NHPs with the Stellar EO system and 16 eyes of 12 NHPs with the Stellar IO system (both measure at 200 Hz for 15 s of every 150 s period). IOP transducers were calibrated bi-weekly via anterior chamber manometry. Linear mixed effects models assessed the differences in the hourly transient IOP impulse, and transient IOP fluctuation frequency and magnitude between systems and transducer placements (EO versus IO). All systems measured 8000-12,000 and 5000-6500 transient IOP fluctuations per hour>0.6 mmHg, representing 8-16% and 4-8% of the total IOP energy the eye must withstand during waking and sleeping hours, respectively. Differences between sampling frequency/duty cycle and transducer placement were statistically significant (p<0.05) but the effect sizes were small and clinically insignificant. IOP dynamics can be accurately captured by sampling IOP at 200 Hz on a 10% duty cycle using either IO or EO transducers.
引用
收藏
页数:10
相关论文
共 50 条
[41]   Transient Intraocular Pressure Fluctuations After Intravitreal Bevacizumab Injection in Proliferative Diabetic Retinopathy Patients: A Prospective Study [J].
Luqman, Faizan ;
Bibi, Hafsa ;
Mukhtar, Marwa ;
Zafar, Fahad ;
Ahmed, Hafsa ;
Khizer, Muhammad A. ;
Gul, Nazli .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (09)
[42]   Analysis of the diurnal intraocular pressure profile pre and post trabeculectomy using 24-hour monitoring of intraocular pressure [J].
Ross, Adam H. ;
Jackson, Thomas E. ;
Wertheim, Michael S. ;
Spry, Paul G. D. ;
Sparrow, John M. ;
Diamond, Jeremy P. .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2011, 21 (04) :400-403
[43]   Repeatability of the Novel Intraocular Pressure Measurement From Corvis ST [J].
Matsuura, Masato ;
Murata, Hiroshi ;
Fujino, Yuri ;
Yanagisawa, Mieko ;
Nakao, Yoshitaka ;
Nakakura, Shunsuke ;
Kiuchi, Yoshiaki ;
Asaoka, Ryo .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2019, 8 (03)
[44]   What to do if the intraocular pressure measurement does not appear reliable? [J].
Hamard, P. .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2010, 33 (04) :279-284
[45]   Efficacy of selective laser trabeculoplasty on lowering intraocular pressure fluctuations and nocturnal peak intraocular pressure in treated primary open-angle glaucoma patients [J].
Pillunat, Karin R. ;
Kocket, Greta A. ;
Herber, Robert ;
Jasper, Carolin S. ;
Lenk, Janine ;
Pillunat, Lutz E. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (07) :1979-1985
[46]   Intraocular Pressure Variations After Intravitreal Injections Measured With an Implanted Suprachoroidal Telemetry Sensor [J].
Meduri, Enrico ;
Gillmann, Kevin ;
Mansouri, Kaweh .
JOURNAL OF GLAUCOMA, 2021, 30 (08) :E360-E363
[47]   Magnetic Design for an IPT based Wireless Intraocular Pressure Regulating Implant [J].
Xu, Qing ;
Thrimawithana, Duleepa J. ;
Svirskis, Darren ;
Rupenthal, Ilva Dana .
2017 IEEE SOUTHERN POWER ELECTRONICS CONFERENCE (SPEC), 2017, :525-530
[48]   Design of a Wireless Intraocular Pressure Monitoring System for a Glaucoma Drainage Implant [J].
Kakaday, T. ;
Plunkett, M. ;
McInnes, S. ;
Li, J. S. Jimmy ;
Voelcker, N. H. ;
Craig, J. E. .
13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3) :198-+
[49]   Design of wireless contact-lens antenna for intraocular pressure monitoring [J].
Priya, L. ;
Vijitha, J. ;
Alagappan, M. .
INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2019, 31 (03) :315-323
[50]   Diurnal Intraocular Pressure Fluctuations with Self-tonometry in Glaucoma Patients and Suspects: A Clinical Trial [J].
Huang, Jessie ;
Katalinic, Paula ;
Kalloniatis, Michael ;
Hennessy, Michael P. ;
Zangerl, Barbara .
OPTOMETRY AND VISION SCIENCE, 2018, 95 (02) :88-95