Comparison of extraocular and intraocular pressure transducers for measurement of transient intraocular pressure fluctuations using continuous wireless telemetry

被引:4
作者
Jasien, Jessica, V [1 ]
Zohner, Ye Emma [2 ]
Asif, Sonia Kuhn [3 ]
Rhodes, Lindsay A. [3 ]
Samuels, Brian C. [3 ]
Girkin, Christopher A. [3 ]
Morris, Jeffrey S. [4 ]
Downs, J. Crawford [3 ]
机构
[1] Univ Alabama Birmingham, Sch Optometry, Vis Sci Grad Program, Birmingham, AL 35294 USA
[2] Rice Univ, Houston, TX USA
[3] Univ Alabama Birmingham, Sch Med, Dept Ophthalmol & Visual Sci, VH 390B,1670 Univ Blvd, Birmingham, AL 35294 USA
[4] Univ Penn, Perelman Sch Med, Philadelphia, PA 19104 USA
关键词
LAMINA-CRIBROSA; RISK-FACTOR; IOP; MAGNITUDE; PROGRESSION; FREQUENCY; SENSOR;
D O I
10.1038/s41598-020-77880-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The optimal approach for continuous measurement of intraocular pressure (IOP), including pressure transducer location and measurement frequency, is currently unknown. This study assessed the capability of extraocular (EO) and intraocular (IO) pressure transducers, using different IOP sampling rates and duty cycles, to characterize IOP dynamics. Transient IOP fluctuations were measured and quantified in 7 eyes of 4 male rhesus macaques (NHPs) using the Konigsberg EO system (continuous at 500 Hz), 12 eyes of 8 NHPs with the Stellar EO system and 16 eyes of 12 NHPs with the Stellar IO system (both measure at 200 Hz for 15 s of every 150 s period). IOP transducers were calibrated bi-weekly via anterior chamber manometry. Linear mixed effects models assessed the differences in the hourly transient IOP impulse, and transient IOP fluctuation frequency and magnitude between systems and transducer placements (EO versus IO). All systems measured 8000-12,000 and 5000-6500 transient IOP fluctuations per hour>0.6 mmHg, representing 8-16% and 4-8% of the total IOP energy the eye must withstand during waking and sleeping hours, respectively. Differences between sampling frequency/duty cycle and transducer placement were statistically significant (p<0.05) but the effect sizes were small and clinically insignificant. IOP dynamics can be accurately captured by sampling IOP at 200 Hz on a 10% duty cycle using either IO or EO transducers.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Design of an Optical Pressure Measurement System for Intraocular Pressure Monitoring
    Phan, Alex
    Phuong Truong
    Trumpp, Julian
    Talke, Frank E.
    IEEE SENSORS JOURNAL, 2018, 18 (01) : 61 - 68
  • [22] Risk factors of glaucoma progression: Intraocular pressure fluctuations
    Aptel, F.
    Denis, P.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2011, 34 (06): : 400 - 402
  • [23] The Development of a RFID Based Mixed Signal ASIC for the Wireless Measurement of Intraocular Pressure
    Turner, Matthew
    Naber, John
    2010 18TH BIENNIAL UNIVERSITY/GOVERNMENT/INDUSTRY MICRO-NANO SYMPOSIUM, 2010,
  • [24] Intraocular pressure fluctuations: how much do they matter?
    Singh, Kuldev
    Shrivastava, Anurag
    CURRENT OPINION IN OPHTHALMOLOGY, 2009, 20 (02) : 84 - 87
  • [25] Effect of anesthesia on intraocular pressure measurement in children
    Mikhail, Mikel
    Sabri, Kourosh
    Levin, Alex V.
    SURVEY OF OPHTHALMOLOGY, 2017, 62 (05) : 648 - 658
  • [26] Continuous intraocular pressure (IOP) measurement during glaucoma drainage device implantation
    Gouws, Pieter
    Moss, Edward B.
    Trope, Graham E.
    Ethier, C. Ross
    JOURNAL OF GLAUCOMA, 2007, 16 (03) : 329 - 333
  • [27] An ultralow power wireless intraocular pressure monitoring system
    Liu Demeng
    Mei Niansong
    Zhang Zhaofeng
    JOURNAL OF SEMICONDUCTORS, 2014, 35 (10)
  • [28] Rapid and Accurate Pressure Sensing Device for Direct Measurement of Intraocular Pressure
    Gopesh, Tilvawala
    Camp, Andrew
    Unanian, Michael
    Friend, James
    Weinreb, Robert N.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (03):
  • [29] Impact of intraocular pressure fluctuations on progression of normal tension glaucoma
    Hopf, Susanne
    Schwarauschke, Doris
    Schmidtmann, Irene
    Pfeiffer, Norbert
    Hoffmann, Esther Maria
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2021, 14 (10) : 1553 - 1559
  • [30] Posture-related fluctuations of intraocular pressure in healthy children with suspicion of glaucoma
    Lueke, Jan Niklas
    Enders, Philip
    Haendel, Alexander
    Gietzelt, Caroline
    Dietlein, Johanna
    Schoeneberger, Verena
    Lappa, Alexandra
    Widder, Randolf
    Dietlein, Thomas S.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (01) : 171 - 177