Determination of inorganic anions in biological fluids with direct sample injection by electrostatic ion chromatography using zwitterionic micelles in both stationary and mobile phases

被引:14
|
作者
Hu, WZ [1 ]
Tanaka, K
Hasebe, K
机构
[1] Hokkaido Univ, Grad Sch Sci, Div Chem, Sapporo, Hokkaido 0600810, Japan
[2] Natl Ind Res Inst Nagoya, Nagoya, Aichi 4628510, Japan
[3] Hokkaido Univ, Grad Sch Environm & Earth Sci, Sapporo, Hokkaido 0600810, Japan
关键词
D O I
10.1039/a908416i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new ion chromatographic (IC) system, which uses zwitterionic (e.g., Zwittergent 3-14) micelles as both stationary and mobile phases, highly useful for the analysis of inorganic anions in biological samples, was developed. The zwitterionic micellar stationary phase (which is obtained by immobilizing the zwitterionic surfactant on surfaces of the reversed-phase ODS) showed high ability to confine the elution bands of the large amount of SO42- and Cl- to narrow zones. As a result, a base-line separation of NO2-, Br- and NO3- from SO42- and Cl- is always achieved. The zwitterionic micellar mobile phase, (which is obtained by dissolving the zwitterionic surfactant with a suppressive electrolytic solution, e.g., aqueous NaHCO3 solution), on the other hand, showed high ability for rapid elution of proteins. The separation column is therefore always being cleaned up even after the protein-containing sample is directly injected. The zwitterionic micelles are also insensitive to conductivity detection, therefore either the suppressed or the non-suppressed conductivity detection method is applicable for detection of the analyte ions. Urine and serum were chosen as the model real samples and were analysed with direct sample injection; the results of successful determination of a number of inorganic anions (SO42-, Cl-, NO2-, Br- and NO3-) in both samples have demonstrated the usefulness of this new IC system.
引用
收藏
页码:447 / 451
页数:5
相关论文
共 30 条
  • [1] Analysis of inorganic anions by electrostatic ion chromatography using zwitterionic/cationic mixed micelles as the stationary phase
    Hu, WZ
    Haddad, PR
    Hasebe, K
    Cook, HA
    Fritz, JS
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (07): : 641 - 644
  • [2] Analysis of inorganic anions by electrostatic ion chromatography using zwitterionic/cationic mixed micelles as the stationary phase
    Wenzhi Hu
    Paul R. Haddad
    Kyioshi Hasebe
    Helmy A. Cook
    James S. Fritz
    Fresenius' Journal of Analytical Chemistry, 2000, 367 : 641 - 644
  • [3] Use of zwitterionic micelles in the eluent II: a new approach to ion chromatographic analysis of inorganic cations in biological fluids with direct sample injection
    Hu, WZ
    Matsukami, H
    Iles, A
    Hasebe, K
    Cao, SN
    Tanaka, K
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (04): : 426 - 428
  • [4] Use of zwitterionic micelles in the eluent II: a new approach to ion chromatographic analysis of inorganic cations in biological fluids with direct sample injection
    W. Hu
    Hidenori Matsukami
    Alexander Iles
    Kiyoshi Hasebe
    Shunan Cao
    Kazuhiko Tanaka
    Fresenius' Journal of Analytical Chemistry, 2001, 370 : 426 - 428
  • [5] Simultaneous separation of inorganic cations and anions by ion chromatography using strong anionic/zwitterionic mixed micelles as the stationary phase
    Hu, WZ
    Hasebe, K
    Reynolds, DM
    Haraguchi, H
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (08) : 1221 - 1232
  • [6] Use of zwitterionic micelles in the eluent: a new approach for ion chromatographic (IC) analysis of ions in biological fluids with direct sample injection
    Hu, WZ
    Hasebe, K
    Tanaka, K
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (01): : 56 - 59
  • [7] Use of zwitterionic micelles in the eluent: a new approach for ion chromatographic (IC) analysis of ions in biological fluids with direct sample injection
    W. Hu
    Kyoshi Hasebe
    Kazuhiko Tanaka
    Fresenius' Journal of Analytical Chemistry, 2000, 367 : 56 - 59
  • [8] Counterionic detection by ICP-AES for determination of inorganic anions in water elution ion chromatography using a zwitterionic stationary phase
    Umemura, T
    Kitaguchi, R
    Haraguchi, H
    ANALYTICAL CHEMISTRY, 1998, 70 (05) : 936 - 942
  • [9] Automated sample preparation techniques for the determination of drug enantiomers in biological fluids using liquid chromatography with chiral stationary phases
    Ceccato, A
    Toussaint, B
    Chiap, P
    Hubert, P
    Crommen, J
    ENANTIOMER, 1999, 4 (3-4): : 305 - 315
  • [10] Manipulation of separation selectivity of inorganic anions in electrostatic ion chromatography by the use of mixed cationic-zwitterionic micelles as the column coating solution
    Hu, W
    Haddad, PR
    Cook, H
    Yamamoto, H
    Hasebe, K
    Tanaka, K
    Fritz, JS
    JOURNAL OF CHROMATOGRAPHY A, 2001, 920 (1-2) : 95 - 100