Sensitivity of volumetric modulated arc therapy patient specific QA results to multileaf collimator errors and correlation to dose volume histogram based metrics

被引:40
作者
Coleman, Linda [1 ]
Skourou, Christina [2 ]
机构
[1] Univ Hosp Galway, Galway, Ireland
[2] St Lukes Radiat Oncol Network, Dublin, Ireland
关键词
VMAT; Rapidarc; quality assurance; gamma-index; 3DVH; QUALITY-ASSURANCE; PER-BEAM; IMRT; VERIFICATION;
D O I
10.1118/1.4824433
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study investigates the impact of systematic multileaf collimator (MLC) positional errors on gamma analysis results used for quality assurance (QA) of Rapidarc treatments. In addition, this study evaluates the relationship of these gamma analysis results and clinical dose volume histogram metrics (DVH) for Rapidarc treatment plans. Methods: Five prostate plans were modified by the introduction of systematic MLC errors. The MLC shifts to each individual active leaf introduced were 0.25, 0.5, 0.75, and 1 mm. All QA verification plans were delivered and estimated 3D patient dose or high density phantom dose were obtained based on the ArcCHECK measurement files. QA gamma analysis of 3%/3 mm and 2%/2 mm were implemented and relationships to dose differences in DVH metrics encountered due to MLC errors were determined. Tolerances of 3% and 5% for DVH metric were implemented to determine the sensitivity of gamma analysis to MLC errors. A calculation of sensitivity was determined from the number of incidences of false negative and false positive cases in gamma analysis results. Results: The sensitivity of global gamma analysis for criteria of 3%/3 mm was 0.78 and for 2%/2 mm was 0.82. A number of instances occurred for an acceptable VMAT QA gamma index which did not indicate a DVH metric dose error greater than 5%. The correlation between global gamma analysis using criteria 3%/3 mm and DVH metric dose error were all <0.8 indicating less than a strong correlation. Conclusions: There is a greater sensitivity for detection of dosimetric errors occurring in a Rapidarc plan using gamma criteria of 2%/2 mm than 3%/3 mm. However, there is lack of consistently strong correlation between global gamma indexes and clinical DVH metrics for PTV and bladder and rectum for Rapidarc plans. It is recommended that the sole use of gamma index for Rapidarc QA plan evaluation could be insufficient and a methodology for evaluation of delivered dose to patient is required. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:7
相关论文
共 14 条
[1]   3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification [J].
Carrasco, Pablo ;
Jornet, Nuria ;
Latorre, Artur ;
Eudaldo, Teresa ;
Ruiz, Agusti ;
Ribas, Montserrat .
MEDICAL PHYSICS, 2012, 39 (08) :5040-5049
[2]  
Daniel J. O., 2012, INT J RADIAT ONCOL, V82, P1567
[3]   On the sensitivity of common gamma-index evaluation methods to MLC misalignments in Rapidarc quality assurance [J].
Heilemann, G. ;
Poppe, B. ;
Laub, W. .
MEDICAL PHYSICS, 2013, 40 (03)
[4]   Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy [J].
Letourneau, Daniel ;
Publicover, Julia ;
Kozelka, Jakub ;
Moseley, Douglas J. ;
Jaffray, David A. .
MEDICAL PHYSICS, 2009, 36 (05) :1813-1821
[5]   A technique for the quantitative evaluation of dose distributions [J].
Low, DA ;
Harms, WB ;
Mutic, S ;
Purdy, JA .
MEDICAL PHYSICS, 1998, 25 (05) :656-661
[6]   Quality assurance of volumetric modulated arc therapy: Evaluation and comparison of different dosimetric systems [J].
Masi, L. ;
Casamassima, F. ;
Doro, R. ;
Francescon, P. .
MEDICAL PHYSICS, 2011, 38 (02) :612-621
[7]  
Nehns B., 2012, MED PHYS, V39, P4228
[8]   Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors [J].
Nelms, Benjamin E. ;
Zhen, Heming ;
Tome, Wolfgang A. .
MEDICAL PHYSICS, 2011, 38 (02) :1037-1044
[9]   Understanding the impact of RapidArc therapy delivery errors for prostate cancer [J].
Oliver, Mike ;
Bush, Karl ;
Zavgorodni, Sergei ;
Ansbacher, Will ;
Beckham, Wayne A. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (03) :32-43
[10]   Clinical significance of multi-leaf collimator positional errors for volumetric modulated arc therapy [J].
Oliver, Mike ;
Gagne, Isabelle ;
Bush, Karl ;
Zavgorodni, Sergei ;
Ansbacher, Will ;
Beckham, Wayne .
RADIOTHERAPY AND ONCOLOGY, 2010, 97 (03) :554-560