DIRECT MEASUREMENTS OF SKIN, EYE LENS AND THYROID DOSE DURING PEDIATRIC BRAIN CT EXAMINATIONS

被引:7
作者
Ploussi, Agapi [1 ]
Stathopoulos, Ioannis [1 ]
Syrgiamiotis, Vasileios [2 ]
Makri, Triantafillia [2 ]
Hatzigiorgi, Christiana [2 ]
Platoni, Kalliopi [1 ]
Carinou, Eleftheria [3 ]
Efstathopoulos, Efstathios P. [1 ]
机构
[1] Univ Athens, Univ Gen Hosp Attikon, Sch Med, Dept Radiol 2, Athens 12462, Greece
[2] Childrens Hosp Agia Sophia, CT MRI Dept, Athens 11527, Greece
[3] GAEC, Attiki 15310, Greece
关键词
COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; CANCER-RISK; THRESHOLD; DOSIMETRY;
D O I
10.1093/rpd/ncx251
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pediatric brain computed tomography (CT) is identified as the most frequent CT examination in children. The aim of the study is the direct measurement of skin, eye lens and thyroid dose in pediatric patients during brain CT examinations. The study included 35 pediatric patients who underwent brain CT examinations. The patients were categorized in three age groups: Group A (age range: 0.8-1 years), Group B (age range: 2.0-4.9 years) and Group C (age range: 5.5-15.5 years). thermoluminescent dosimeters (TLDs) were placed on the eyes, the frontal region of the head, the mastoid apophysis and the thyroid gland. The skin dose was found 16.6 +/- 1.5, 38.8 +/- 5.1 and 41.7 +/- 9.4 mGy for Groups A, B and C, respectively. The mean dose for the eye lens was 10.5 +/- 3.3, 29.9 +/- 8.6 and 34.2 +/- 14.9mGy and for the thyroid 1.7 +/- 0.4, 2.4 +/- 0.5 and 1.9 +/- 0.4mGy for Groups A, B and C, respectively. In vivo dosimetry using TLDs proved to be an efficient method. Gantry tilting and patient's set-up seem to significantly affect eye lens dose.
引用
收藏
页码:199 / 205
页数:7
相关论文
共 27 条
  • [1] Estimating thyroid dose in pediatric CT exams from surface dose measurement
    Al-Senan, Rani
    Mueller, Deborah L.
    Hatab, Mustapha R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (13) : 4211 - 4221
  • [2] American Association of Physicists in Medicine AAPM, 2011, AAPM report 204, P1
  • [3] [Anonymous], 2007, The 2007 Recommendations of the International Commission on Radiological Protection
  • [4] Azorin J., 2008, IRPA 12 12 INT C INT
  • [5] Current concepts - Computed tomography - An increasing source of radiation exposure
    Brenner, David J.
    Hall, Eric J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) : 2277 - 2284
  • [6] DIMENSIONS OF HUMAN EYE RELEVANT TO RADIATION PROTECTION
    CHARLES, MW
    BROWN, N
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1975, 20 (02) : 202 - 218
  • [7] Risk of cataract after exposure to low doses of ionizing radiation: A 20-year prospective cohort study among US radiologic technologists
    Chodick, Gabriel
    Bekiroglu, Nural
    Hauptmann, Michael
    Alexander, Bruce H.
    Freedman, D. Michal
    Doody, Michele Morin
    Cheung, Li C.
    Simon, Steven L.
    Weinstock, Robert M.
    Bouville, Andre
    Sigurdson, Alice J.
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 2008, 168 (06) : 620 - 631
  • [8] Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product
    Deak, Paul D.
    Smal, Yulia
    Kalender, Willi A.
    [J]. RADIOLOGY, 2010, 257 (01) : 158 - 166
  • [9] Patient-specific CT dosimetry calculation: a feasibility study
    Fearon, Thomas
    Xie, Huchen
    Cheng, Jason Y.
    Ning, Holly
    Zhuge, Ying
    Miller, Robert W.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (04): : 196 - 209
  • [10] ICRP, 2012, ICRP PUBL, V118, P40