Standardized surveillance of hemodialysis vascular access infections: 18-month experience at an outpatient, multifacility hemodialysis center

被引:67
作者
Stevenson, KB
Adcox, MJ
Mallea, MC
Narasimhan, N
Wagnild, JP
机构
[1] Intermt Infect Control, Boise, ID 83704 USA
[2] St Alphonsus Nephrol Ctr, Boise, ID USA
[3] Idaho Nephrol Associates LLC, Boise, ID USA
关键词
D O I
10.1086/501744
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
OBJECTIVE: To develop a standardized surveillance system for monitoring hemodialysis vascular-access infections in order to compare infection rates between outpatient sites and to assess the effectiveness of infection control interventions. DESIGN: Prospective descriptive analysis of incidence infection rates. SETTING: An outpatient hemodialysis center with facilities in Idaho and Oregon. PATIENTS: All outpatients receiving chronic outpatient hemodialysis. RESULTS: There were 38,096 hemodialysis sessions (31,603 via permanent fistulae or grafts, 5,060 via permanent tunneled central catheters, and 1,433 via temporary catheters) during an 18-month study period in 1997 to 1998. We identified 176 total infections, for a rate of 4.62/1,000 dialysis sessions (ds). Of the 176, 80 involved per moment fistulae or grafts (2.53/1,000 ds), 69 involved permanent tunneled central catheter infections (13.64/1,000 ds), and 27 involved temporary catheter infections (18.84/1,000 ds). There were 35 blood-stream infections (0.92/1,000 ds) and 10 episodes of clinical sepsis (0.26 /1,000 ds). One hundred thirty-one vascular-site infections without bacteremia were identified (3.44/1,000 ds), including 65 permanent fistulae or graft infections (2.06/1,000 ds), 42 permanent tunneled central catheter infections (8.3/1,000 ds),and 24 temporary catheter infections (16.75/1,000 ds). CONCLUSIONS: Infection rates were highest among temporary catheters and lowest among permanent native arteriovenous fistulae or synthetic grafts. This represents the first report of extensive incidence data on hemodialysis vascular access infections and represents a standardized surveillance and data-collection system that could be implemented in hemodialysis facilities to allow for reliable data comparison and benchmarking.
引用
收藏
页码:200 / 203
页数:4
相关论文
共 46 条
[1]   INFECTION OF HEMODIALYSIS CATHETERS - INCIDENCE AND MECHANISMS [J].
ALMIRALL, J ;
GONZALEZ, J ;
RELLO, J ;
CAMPISTOL, JM ;
MONTOLIU, J ;
DELABELLACASA, JP ;
REVERT, L ;
GATELL, JM .
AMERICAN JOURNAL OF NEPHROLOGY, 1989, 9 (06) :454-459
[2]  
ALMON R, 1994, CLIN MICROBIOLOGY PR
[3]   BOVINE CAROTID-ARTERY AND EXPANDED POLYTETRAFLUROETHYLENE GRAFTS FOR HEMODIALYSIS VASCULAR ACCESS [J].
ANDERSON, CB ;
SICARD, GA ;
ETHEREDGE, EE .
JOURNAL OF SURGICAL RESEARCH, 1980, 29 (02) :184-188
[4]  
BANERJEE SN, 1991, AM J MED S3B, V91, P86
[5]  
BHAT DJ, 1980, SURGERY, V87, P445
[6]   THE USE OF DUAL LUMEN JUGULAR VENOUS CATHETERS AS DEFINITIVE LONG-TERM ACCESS FOR HEMODIALYSIS [J].
BLAKE, PG ;
HURAIB, S ;
WU, G ;
ULDALL, PR .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1990, 13 (01) :26-31
[7]  
Bonomo RA, 1997, INFECT CONT HOSP EP, V18, P757
[8]  
BOUR ES, 1990, SURG GYNECOL OBSTET, V171, P33
[9]   CENTRAL VENOUS ACCESS FOR HEMODIALYSIS USING THE HICKMAN CATHETER [J].
CAPPELLO, M ;
DEPAUW, L ;
BASTIN, G ;
PROSPERT, F ;
DELCOUR, C ;
THAYSSE, C ;
DHAENE, M ;
VANHERWEGHEM, JL ;
KINNAERT, P .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1989, 4 (11) :988-992
[10]   A PROSPECTIVE-STUDY OF THE MECHANISMS OF INFECTION ASSOCIATED WITH HEMODIALYSIS CATHETERS [J].
CHEESBROUGH, JS ;
FINCH, RG ;
BURDEN, RP .
JOURNAL OF INFECTIOUS DISEASES, 1986, 154 (04) :579-596