Two-dimensional EPID dosimetry for an MR-linac: Proof of concept

被引:10
作者
Torres-Xirau, Iban [1 ]
Olaciregui-Ruiz, Igor [1 ]
van der Heide, Uulke A. [1 ]
Mans, Anton [1 ]
机构
[1] Antoni van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
关键词
dose verification; EPID; MR-linac; portal dosimetry; QA; unity; PORTAL IMAGING DEVICE; BACK-PROJECTION ALGORITHM; BODY RADIATION-THERAPY; 3D DOSE RECONSTRUCTION; MODULATED ARC THERAPY; MAGNETIC-RESONANCE; VERIFICATION; IMRT; RADIOTHERAPY; PERFORMANCE;
D O I
10.1002/mp.13664
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose At our institute, in vivo patient dose distributions are reconstructed for all treatments delivered using conventional linacs from electronic portal imaging device (EPID) transit images acquired during treatment using a simple back-projection model. Currently, the clinical implementation of MRI-guided radiotherapy systems, which aims for online and real-time adaptation of the treatment plan, is progressing. In our department, the MR-linac (Unity, Elekta AB, Stockholm, Sweden) is now in clinical use. The aim of this work is to demonstrate the feasibility of two-dimensional (2D) EPID dosimetric verification for the magnetic resonance (MR)-linac by comparing back-projected EPID doses to ionization chamber (IC) array dose distributions. Materials and methods Our conventional back-projection algorithm was adapted for the MR-linac. The most important changes involve modeling of the attenuation by and scatter from the cryostat. The commissioning process involved the acquisition of square field EPID measurements using various phantom setups (varying SSD, phantom thickness, and field size). Commissioning models were created for gantry 0 degrees, 90 degrees, and 180 degrees and verified by comparing EPID-reconstructed 2D dose distributions to measurements made with the OCTAVIUS 1500 IC array (PTW, Freiburg, Germany) for two prostate and one rectum IMRT plans (25 beams total). The average of the gamma parameters (y-mean and y-pass rate) and the dose difference at a reference point were reported. Due to their construction, the attenuation of couch, bridge, and cryostat shows a much stronger dependence on gantry angle in the MR-linac compared to conventional linacs. We present a method to correct for these effects. This method is validated by dose reconstruction of the 25 intensity-modulated radiation therapy beams recorded at a certain gantry angle using the model of another gantry angle, combined with the correction method. Results For dose verification performed at a gantry angle identical to the commissioned model, the average y-mean and y-pass rate values (3% global dose, 2 mm, 10% isodose) were 0.37 +/- 0.07 and 98.1, 95% CI [98.1 +/- 2.4], respectively. The average dose difference at the reference point was -0.5% +/- 1.8%. Verification at gantry angles different from the commissioned model (i.e., using the gantry angle dependent correction) reported 0.39 +/- 0.08 and 97.6, 95% CI [96.9, 98.3] average y-mean and y-pass rate values. The average dose difference at the reference point was -0.1% +/- 1.8%. Conclusion The EPID dosimetry back-projection model was successfully adapted for the MR-linac at gantry 0 degrees, 90 degrees, and 180 degrees, accounting for the presence of the MRI housing between phantom (or patient) and the EPID. A method to account for the gantry angle dependence was also tested reporting similar results.
引用
收藏
页码:4193 / 4203
页数:11
相关论文
共 50 条
  • [41] Two-dimensional in vivo rectal dosimetry during high-dose-rate brachytherapy for cervical cancer: a phantom study
    Jeang, Eun Hee
    Goh, Youngmoon
    Cho, Kwan Ho
    Min, Soonki
    Choi, Sang Hyoun
    Jeong, Hojin
    Jo, Kwanghyun
    Lee, Nuri
    Song, Sanghyeon
    Lee, Se Byeong
    Shin, Dongho
    Kim, Yeon-Joo
    Kim, Joo-Young
    Kim, Dae Yong
    Hwang, Ui-Jung
    Lim, Young Kyung
    ACTA ONCOLOGICA, 2018, 57 (10) : 1359 - 1366
  • [42] Cardiac-triggered and segmented two-dimensional MR angiography of peripheral arterial occlusive disease - A pictorial essay
    Safir, J
    Purdy, D
    Zito, JL
    CLINICAL IMAGING, 1998, 22 (02) : 134 - 144
  • [43] Low-Power Adiabatic Sequences for In Vivo Localized Two-Dimensional Chemical Shift Correlated MR Spectroscopy
    Andronesi, Ovidiu C.
    Ramadan, Saadallah
    Mountford, Carolyn E.
    Sorensen, A. Gregory
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (06) : 1542 - 1556
  • [44] Diagnosis of acetabular labral tears: comparison of three-dimensional intermediate-weighted fast spin-echo MR arthrography with two-dimensional MR arthrography at 3.0 T
    Park, So Young
    Park, Ji Seon
    Jin, Wook
    Rhyu, Kee Hyung
    Ryu, Kyung Nam
    ACTA RADIOLOGICA, 2013, 54 (01) : 75 - 82
  • [45] Comparison of the performance between portal dosimetry and a commercial two-dimensional array system on pretreatment quality assurance for volumetric-modulated arc and intensity-modulated radiation therapy
    Yon-Lae Kim
    Jin-Beom Chung
    Jae-Sung Kim
    Jeong-Woo Lee
    Kyoung-Sik Choi
    Journal of the Korean Physical Society, 2014, 64 : 1207 - 1212
  • [46] In vivo measurement of brain metabolites using two-dimensional double-quantum MR spectroscopy - Exploration of GABA levels in a ketogenic diet
    Wang, ZYJ
    Bergqvist, C
    Hunter, JV
    Jin, DZ
    Wang, DJY
    Wehrli, S
    Zimmerman, RA
    MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (04) : 615 - 619
  • [47] Two-dimensional thick-slice MR digital subtraction anglography in the assessment of small to medium-size intracranial arteriovenous malformations
    Mori, H
    Aoki, S
    Okubo, T
    Hayashi, N
    Masumoto, T
    Yoshikawa, T
    Tago, M
    Shin, M
    Kurita, H
    Abe, O
    Ohtomo, K
    NEURORADIOLOGY, 2003, 45 (01) : 27 - 33
  • [48] Two-dimensional Thermoluminescence Dosimetry Using Al2O3:Cr Ceramics for 4, 6, and 10 MV X-ray Beams
    Yanagisawa, Shin
    Maruyama, Daiki
    Oh, Ryoken
    Koba, Yusuke
    Andoh, Takayuki
    Shinsho, Kiyomitsu
    SENSORS AND MATERIALS, 2020, 32 (04) : 1479 - 1487
  • [49] Two-dimensional real-time dosimetry system using micro-and nano-( C 44 H 38 P 2 )MnCl 4 radioluminescence coatings
    Nascimento, Luana de Freitas
    De Saint-Hubert, Marijke
    Crijns, Wouter
    Caprioli, Marco
    Delombaerde, Laurence
    Vandenbroucke, Dirk
    Leblans, Paul
    Sterckx, Paul
    Himschoot, Katleen
    Goossens, Jo
    Vanreusel, Verdi
    Verellen, Dirk
    RADIATION MEASUREMENTS, 2024, 176
  • [50] Supratentorial cerebrospinal fluid production rate in healthy adults: Quantification with two-dimensional cine phase-contrast MR Imaging with high temporal and spatial resolution
    Huang, TY
    Chung, HW
    Chen, MY
    Giiang, LH
    Chin, SC
    Lee, CS
    Chen, CY
    Liu, YJ
    RADIOLOGY, 2004, 233 (02) : 603 - 608