Two-dimensional EPID dosimetry for an MR-linac: Proof of concept

被引:10
作者
Torres-Xirau, Iban [1 ]
Olaciregui-Ruiz, Igor [1 ]
van der Heide, Uulke A. [1 ]
Mans, Anton [1 ]
机构
[1] Antoni van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
关键词
dose verification; EPID; MR-linac; portal dosimetry; QA; unity; PORTAL IMAGING DEVICE; BACK-PROJECTION ALGORITHM; BODY RADIATION-THERAPY; 3D DOSE RECONSTRUCTION; MODULATED ARC THERAPY; MAGNETIC-RESONANCE; VERIFICATION; IMRT; RADIOTHERAPY; PERFORMANCE;
D O I
10.1002/mp.13664
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose At our institute, in vivo patient dose distributions are reconstructed for all treatments delivered using conventional linacs from electronic portal imaging device (EPID) transit images acquired during treatment using a simple back-projection model. Currently, the clinical implementation of MRI-guided radiotherapy systems, which aims for online and real-time adaptation of the treatment plan, is progressing. In our department, the MR-linac (Unity, Elekta AB, Stockholm, Sweden) is now in clinical use. The aim of this work is to demonstrate the feasibility of two-dimensional (2D) EPID dosimetric verification for the magnetic resonance (MR)-linac by comparing back-projected EPID doses to ionization chamber (IC) array dose distributions. Materials and methods Our conventional back-projection algorithm was adapted for the MR-linac. The most important changes involve modeling of the attenuation by and scatter from the cryostat. The commissioning process involved the acquisition of square field EPID measurements using various phantom setups (varying SSD, phantom thickness, and field size). Commissioning models were created for gantry 0 degrees, 90 degrees, and 180 degrees and verified by comparing EPID-reconstructed 2D dose distributions to measurements made with the OCTAVIUS 1500 IC array (PTW, Freiburg, Germany) for two prostate and one rectum IMRT plans (25 beams total). The average of the gamma parameters (y-mean and y-pass rate) and the dose difference at a reference point were reported. Due to their construction, the attenuation of couch, bridge, and cryostat shows a much stronger dependence on gantry angle in the MR-linac compared to conventional linacs. We present a method to correct for these effects. This method is validated by dose reconstruction of the 25 intensity-modulated radiation therapy beams recorded at a certain gantry angle using the model of another gantry angle, combined with the correction method. Results For dose verification performed at a gantry angle identical to the commissioned model, the average y-mean and y-pass rate values (3% global dose, 2 mm, 10% isodose) were 0.37 +/- 0.07 and 98.1, 95% CI [98.1 +/- 2.4], respectively. The average dose difference at the reference point was -0.5% +/- 1.8%. Verification at gantry angles different from the commissioned model (i.e., using the gantry angle dependent correction) reported 0.39 +/- 0.08 and 97.6, 95% CI [96.9, 98.3] average y-mean and y-pass rate values. The average dose difference at the reference point was -0.1% +/- 1.8%. Conclusion The EPID dosimetry back-projection model was successfully adapted for the MR-linac at gantry 0 degrees, 90 degrees, and 180 degrees, accounting for the presence of the MRI housing between phantom (or patient) and the EPID. A method to account for the gantry angle dependence was also tested reporting similar results.
引用
收藏
页码:4193 / 4203
页数:11
相关论文
共 50 条
  • [31] Increasing Flexibility in Two-Dimensional Liquid Chromatography by Pulsed Elution of the First Dimension: A Proof of Concept
    Jakobsen, Simon S.
    Christensen, Jan H.
    Verdier, Sylvain
    Mallet, Claude R.
    Nielsen, Nikoline J.
    ANALYTICAL CHEMISTRY, 2017, 89 (17) : 8723 - 8730
  • [32] Two-dimensional thermoluminescence dosimetry system for proton beam quality assurance
    Gajewski, J.
    Klosowski, M.
    Olko, P.
    RADIATION MEASUREMENTS, 2016, 90 : 224 - 227
  • [33] Evaluation of an anthropomorphic ion chamber and 3D gel dosimetry head phantom at a 0.35 T MR-linac using separate 1.5 T MR-scanners for gel readout
    Nierer, Lukas
    Kamp, Florian
    Reiner, Michael
    Corradini, Stefanie
    Rabe, Moritz
    Dietrich, Olaf
    Parodi, Katia
    Belka, Claus
    Kurz, Christopher
    Landry, Guillaume
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2022, 32 (03): : 312 - 325
  • [34] Evaluation of two-dimensional dose distributions for pre-treatment patient-specific IMRT dosimetry
    Radojcic, Deni Smilovic
    Rajlic, David
    Casar, Bozidar
    Kolacio, Manda Svabic
    Obajdin, Nevena
    Faj, Dario
    Jurkovic, Slaven
    RADIOLOGY AND ONCOLOGY, 2018, 52 (03) : 346 - 352
  • [35] Two-dimensional in vivo rectal dosimetry using an endorectal balloon with unfoldable radiochromic film during prostate cancer radiotherapy
    Jeang, Eun Hee
    Min, Soonki
    Cho, Kwan Ho
    Hwang, Ui-Jung
    Choi, Sang Hyoun
    Kwak, Jungwon
    Jeong, Jong Hwi
    Kim, Haksoo
    Lee, Se Byeong
    Shin, Dongho
    Park, Jeonghoon
    Kim, Joo-Young
    Kim, Dae Yong
    Lim, Young Kyung
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 (02) : 327 - 332
  • [36] Feasibility of using two-dimensional array dosimeter for in vivo dose reconstruction via transit dosimetry
    Chung, Heeteak
    Li, Jonathan
    Samant, Sanjiv
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (03): : 90 - 111
  • [37] Comparison of the Performance between Portal Dosimetry and a Commercial Two-dimensional Array System on Pretreatment Quality Assurance for Volumetric-modulated Arc and Intensity-modulated Radiation Therapy
    Kim, Yon-Lae
    Chung, Jin-Beom
    Kim, Jae-Sung
    Lee, Jeong-Woo
    Choi, Kyoung-Sik
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (08) : 1207 - 1212
  • [38] The evaluation of the two-dimensional gamma passing rate efficiency for the unilateral breast cancer dosimetry using the Intensity-Modulated Radiation Therapy
    Al-Wakeel, Afnan Fouad
    Al Musawi, Mustafa Salih
    Alabedi, Hayder Hamza
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2024, 74 (10) : S318 - S321
  • [39] Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributions
    Dempsey, JF
    Low, DA
    Mutic, S
    Markman, J
    Kirov, AS
    Nussbaum, GH
    Williamson, JF
    MEDICAL PHYSICS, 2000, 27 (10) : 2462 - 2475
  • [40] DeePSC: A Deep Learning Model for Automated Diagnosis of Primary Sclerosing Cholangitis at Two-dimensional MR Cholangiopancreatography
    Ragab, Haissam
    Westhaeusser, Fabian
    Ernst, Anne
    Yamamura, Jin
    Fuhlert, Patrick
    Zimmermann, Marina
    Sauerbeck, Julia
    Shenas, Farzad
    Oezden, Cansu
    Weidmann, Anna
    Adam, Gerhard
    Bonn, Stefan
    Schramm, Christoph
    RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2023, 5 (03)