Static and dynamic field load testing of the long span Nissibi cable-stayed bridge

被引:41
|
作者
Bayraktar, Alemdar [1 ]
Turker, Temel [1 ]
Tadla, Janusz [2 ]
Kursun, Altok [3 ]
Erdis, Arif [3 ]
机构
[1] Karadeniz Tech Univ, Dept Civil Engn, TR-61080 Trabzon, Turkey
[2] Emay Int Engn & Consultancy Inc, Istanbul, Turkey
[3] Gulsan Grp Co, Istanbul, Turkey
关键词
Cable-stayed bridges; Static loading tests; Dynamic loading tests; Ambient vibration tests; Nissibi Bridge;
D O I
10.1016/j.soildyn.2017.01.019
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The static, ambient and dynamic field tests and observations of the long span Nissibi cable-stayed bridge are given in this paper. For this purpose, the ambient vibration tests, static and dynamic loading tests for different truck positions and observational investigations were implemented between May 16-19, 2015. The mobile dynamic measurement system, geodetic measurement system and bridge fixed monitoring system have been used during these tests. The experimental frequencies and mode shapes of the bridge are obtained using the ambient vibration tests with the Enhanced Frequency Domain Decomposition (EFDD) tehcnique. The static displacements of the deck and towers were determined using geodetic instruments for five different fixed truck positions on the bridge deck. The dynamic measurements were taken from the deck, pylons and cables by using the bridge fixed monitoring and the mobile measurement systems for fifteen dynamic load (DL) cases including the passage of trucks throughout the deck. Before, during and after the measurement, observational inspections on the foundations, bearings, joints, deck, cables and pylons have also been realized. The results obtained from the ambient vibration, static and dynamic loading tests are compared with the analytical results of the bridge.
引用
收藏
页码:136 / 157
页数:22
相关论文
共 50 条
  • [41] Model Updating of Laboratorial Long-span Cable-Stayed Bridge
    Yang, Ou
    Ou, Jinping
    PROCEEDINGS OF THE 2009 SIXTH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY: NEW GENERATIONS, VOLS 1-3, 2009, : 1697 - +
  • [42] Seismic Displacements Reduction for a Long-Span Cable-Stayed Bridge
    Yang, Xi-wen
    Lian, Zi-bao
    ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 840 - +
  • [43] Nonlinear dynamic performance of long-span cable-stayed bridge under traffic and wind
    Han, Wanshui
    Ma, Lin
    Cai, C. S.
    Chen, Suren
    Wu, Jun
    WIND AND STRUCTURES, 2015, 20 (02) : 249 - 274
  • [44] Static Behaviors of a Long-span Cable-Stayed Bridge with a Floating Tower under Dead Loads
    Jang, Minseo
    Lee, Yunwoo
    Won, Deokhee
    Kang, Young-Jong
    Kim, Seungjun
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2020, 8 (10) : 1 - 21
  • [45] GPS Dynamic Monitoring Experiment and Result Analysis of Long-Span Cable-Stayed Bridge
    Huang Shengxiang
    Wu Wentan
    GEO-SPATIAL INFORMATION SCIENCE, 2006, 9 (01) : 1 - 5
  • [46] Cable-beam related vibration of a long span railway cable-stayed bridge
    Wang T.
    Liu D.
    Huang H.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2019, 38 (17): : 103 - 114
  • [47] Study on Fatigue Behavior of Anchorage of Cable and Girder of Long Span Cable-Stayed Bridge
    刘庆宽
    强士中
    张强
    Journal of Southwest Jiaotong University, 2001, (01) : 42 - 49
  • [48] Fatigue life assessment of FRP cable for long-span cable-stayed bridge
    Feng, Bo
    Wang, Xin
    Wu, Zhishen
    COMPOSITE STRUCTURES, 2019, 210 : 159 - 166
  • [49] DYNAMIC BEHAVIOR OF A CABLE-STAYED BRIDGE
    FLEMING, JF
    EGESELI, EA
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1980, 8 (01): : 1 - 16
  • [50] Field Measurement Research on Dynamic Performance of Steel Pylon of a Long-span Cable-stayed Bridge Under Typhoons
    Mao J.-X.
    Gui G.
    Wang H.
    Nie J.-H.
    Zong H.
    He X.-P.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2022, 36 (07): : 102 - 113