Markerless Gait Analysis Vision System for Real-time Gait Monitoring

被引:0
|
作者
Andre, Joao [1 ]
Lopes, Joao [1 ]
Palermo, Manuel [1 ]
Goncalves, Diogo [1 ]
Matias, Ana [2 ]
Pereira, Fatima [2 ]
Afonso, Jose [1 ]
Seabra, Eurico [1 ]
Cerqueira, Joao [3 ]
Santos, Cristina [1 ]
机构
[1] Univ Minho, Braga, Portugal
[2] Hosp Braga, Braga, Portugal
[3] 2CA Braga, Braga, Portugal
来源
2020 IEEE INTERNATIONAL CONFERENCE ON AUTONOMOUS ROBOT SYSTEMS AND COMPETITIONS (ICARSC 2020) | 2020年
关键词
gait; rehabilitation; smart walker; vision;
D O I
10.1109/icarsc49921.2020.9096121
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
On this paper a vision-based contact- and markerless method for gait evaluation is proposed, and validated in different experimental setups against commercial motion capture systems (Vicon) and inertial gait analysis tools (GaitShoes). While the development goal is its integration on the ASBGo Smart Walker platform, only an inexpensive depth camera is required. It is shown to have reasonable results when computing gait metrics in real time, in different experimental setups, from different walker types, vision hardware and walking scenarios. Performance is evaluated through RMSD values for several gait metrics. Results illustrate that the proposed approach can be a valuable non-invasive, contactless and low cost alternative to gait analysis systems used in clinical rehabilitation environments.
引用
收藏
页码:269 / 274
页数:6
相关论文
共 50 条
  • [31] Research on the Mechatronic Gait Monitoring System with Nordic Walking Poles
    Wudarczyk, Slawomir
    Szrek, Jaroslaw
    Balchanowski, Jacek
    Lewadndowski, Bogusz
    Mroz, Sebastian
    Jasinski, Ryszard
    Niebudek, Tadeusz
    Wozniewski, Marek
    15TH INTERNATIONAL CONFERENCE MECHATRONIC SYSTEMS AND MATERIALS, MSM'20, 2020, : 9 - 14
  • [32] Design and Analysis of a Non-Vision-Based System for Detecting Unstable Gait
    Chen, Chin-Hsing
    Yu, Yao-Ming
    Tan, Sun-Yen
    Tseng, Hung-Li
    Huang, Wen-Tzeng
    MECHATRONICS AND APPLIED MECHANICS II, PTS 1 AND 2, 2013, 300-301 : 561 - +
  • [33] Gait Retraining With Real-Time Biofeedback to Reduce Knee Adduction Moment: Systematic Review of Effects and Methods Used
    Richards, Rosie
    van den Noort, Josien C.
    Dekker, Joost
    Harlaar, Jaap
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2017, 98 (01): : 137 - 150
  • [34] Development of a Low-Cost Markerless Optical Motion Capture System for Gait Analysis and Anthropometric Parameter Quantification
    Espitia-Mora, Laura Alejandra
    Velez-Guerrero, Manuel Andres
    Callejas-Cuervo, Mauro
    SENSORS, 2024, 24 (11)
  • [35] Microprocessor-based gait analysis system to retrain Trendelenburg gait
    J. S. Petrofsky
    Medical and Biological Engineering and Computing, 2001, 39 : 140 - 143
  • [36] Microprocessor-based gait analysis system to retrain Trendelenburg gait
    Petrofsky, JS
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2001, 39 (01) : 140 - 143
  • [37] Configurable, wearable sensing and vibrotactile feedback system for real-time postural balance and gait training: proof-of-concept
    Xu, Junkai
    Bao, Tian
    Lee, Ung Hee
    Kinnaird, Catherine
    Carender, Wendy
    Huang, Yangjian
    Sienko, Kathleen H.
    Shull, Peter B.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2017, 14
  • [38] A BODY-WORN GAIT ANALYSIS SYSTEM FOR EVALUATING HEMIPLEGIC GAIT
    GRANAT, MH
    MAXWELL, DJ
    BOSCH, CJ
    FERGUSON, ACB
    LEES, KR
    BARBENEL, JC
    MEDICAL ENGINEERING & PHYSICS, 1995, 17 (05) : 390 - 394
  • [39] Feasibility and usefulness of video-based markerless two-dimensional automated gait analysis, in providing objective quantification of gait and complementing the evaluation of gait in children with cerebral palsy
    Pantzar-Castilla, Evelina
    Balta, Diletta
    Della Croce, Ugo
    Cereatti, Andrea
    Riad, Jacques
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [40] A gait analysis system using foot path images
    Seimitsu Kogaku Kaishi, 2008, 12 (1318-1324): : 1318 - 1324