Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis

被引:17
作者
Liu, Hong-Ting [1 ]
Zhou, Zhou [2 ]
Luo, Wu-Qiang [1 ]
He, Wen-Jing [2 ]
Agbedia, Owhofasa [3 ]
Wang, Jiang-Xia [4 ]
Huang, Jian-Zhong [1 ]
Gao, Xin [5 ]
Kong, Min [1 ]
Li, Min [2 ]
Li, Li [2 ]
机构
[1] Peoples Hosp Guangxi Zhuang Autonomous Reg, Visual Sci & Optometry Ctr, Nanning 530021, Guangxi Zhuang, Peoples R China
[2] Peoples Hosp Guangxi Zhuang Autonomous Reg, Ophthalmol Ctr, Nanning 530021, Guangxi Zhuang, Peoples R China
[3] Johns Hopkins Univ, Wilmer Eye Inst, Baltimore, MD 21211 USA
[4] Johns Hopkins Univ, Sch Publ Hlth, Biostat Dept, Baltimore, MD 21211 USA
[5] Civil Aviat Flight Univ China, Inst Aviat Human Factors & Ergon, Guanghan 618300, Sichuan, Peoples R China
关键词
optical quality; implantable collamer lens; wavefront-guided laser in situ keratomileusis; PHAKIC INTRAOCULAR-LENS; HIGHER-ORDER ABERRATIONS; VISUAL PERFORMANCE; FEMTOSECOND LASER; CONTACT-LENS; MODERATE; LASIK;
D O I
10.18240/ijo.2018.04.20
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To compare the optical quality after implantation of implantable collamer lens (ICL) and wavefront-guided laser in situ keratomileusis (WG-LASIK). METHODS: The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index (OSI), the values of modulation transfer function (MTF) cutoff frequency, Strehl ratio, and the Optical Quality Analysis System (OQAS) values (OVs) were accessed. The higher order aberrations (HOAs) data including coma, trefoil, spherical, 2nd astigmatism and tetrafoil were also obtained. For patients with pupil size <6 mm, HOAs data were analyzed for 4 mm-pupil diameter. For patients with pupil size >= 6 mm, HOAs data were calculated for 6 mm-pupil diameter. Visual acuity, refraction, pupil size and intraocular pressures were also recorded. RESULTS: In both ICL and WG-LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent (P<0.001). After the ICL implantation, the OSI decreased slightly from 2.34 +/- 1.92 to 2.24 +/- 1.18 with no statistical significance (P=0.62). While in WG-LASIK group, the OSI significantly increased from 0.68 +/- 0.43 preoperatively to 0.91 +/- 0.53 postoperatively (Wilcoxon signed ranks test, P=0.000). None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mm-pupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2nd astigmatism were 0.12 +/- 0.06, 0.06 +/- 0.03, 0.00 +/- 0.03, 0.02 +/- 0.01, respectively. After the operation, these values were increased into 0.16 +/- 0.07, 0.08 +/- 0.05, -0.04 +/- 0.04, 0.03 +/- 0.01 respectively (Wilcoxon signed ranks test, all P<0.05). At 6 mm-pupil, the induction of total HOAs was not statistically significant in the WG-LASIK group. CONCLUSION: ICL implantation has a less disturbance to optical quality than WG-LASIK. The OQAS is a valuable complementary measurement to the wavefront aberrometers in evaluating the optical quality.
引用
收藏
页码:656 / 661
页数:6
相关论文
共 25 条
  • [11] Visual Performance After Posterior Chamber Phakic Intraocular Lens Implantation and Wayefront-Guided Laser In Situ Keratomileusis for Low to Moderate Myopia
    Kamiya, Kazutaka
    Igarashi, Akihito
    Shimizu, Kimiya
    Matsumura, Kazuhiro
    Komatsu, Mari
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (06) : 1178 - 1186
  • [12] Kim TI, 2004, J REFRACT SURG, V20, P432
  • [13] Comparison of optical quality parameters and ocular aberrations after wavefront-guided laser in-situ keratomileusis versus wavefront-guided laser epithelial keratomileusis for myopia
    Lee, Kwanghyun
    Ahn, Ji Min
    Kim, Eung Kweon
    Kim, Tae-im
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (09) : 2163 - 2169
  • [14] Effects of aging on optical quality and visual function
    Martinez-Roda, Joan A.
    Vilaseca, Meritxell
    Ondategui, Juan C.
    Aguirre, Montserrat
    Pujol, Jaume
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2016, 99 (06) : 518 - 525
  • [15] Visual Outcomes and Optical Quality After Femtosecond Laser Small Incision Lenticule Extraction: An 18-Month Prospective Study
    Miao, Huamao
    Tian, Mi
    Xu, Ye
    Chen, Yingjun
    Zhou, Xingtao
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (11) : 726 - U72
  • [16] The Tear Film and the Optical Quality of the Eye
    Montes-Mico, Robert
    Cervino, Alejandro
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Madrid-Costa, David
    [J]. OCULAR SURFACE, 2010, 8 (04) : 185 - 192
  • [17] Corneal densitometry after photorefractive keratectomy, laser-assisted in situ keratomileusis, and small-incision lenticule extraction
    Poyales, F.
    Garzon, N.
    Mendicute, J.
    Illarramendi, I.
    Caro, P.
    Janez, O.
    Argueso, F.
    Lopez, A.
    [J]. EYE, 2017, 31 (12) : 1647 - 1654
  • [18] Comparison of implantable collamer lens (ICL) and laser-assisted in situ keratomileusis (LASIK) for low myopia
    Sanders, Donald
    Vukich, John A.
    [J]. CORNEA, 2006, 25 (10) : 1139 - 1146
  • [19] Implantable contact lens for moderate to high myopia: Phase 1 FDA clinical study with 6 month follow-up
    Sanders, DR
    Brown, DC
    Martin, RG
    Shepherd, J
    Deitz, MR
    DeLuca, M
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (05) : 607 - 611
  • [20] Intraindividual Comparison of Visual Performance After Posterior Chamber Phakic Intraocular Lens With and Without a Central Hole Implantation for Moderate to High Myopia
    Shimizu, Kimiya
    Kamiya, Kazutaka
    Igarashi, Akihito
    Shiratani, Tetsu
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (03) : 486 - 494