Smartphone-Based Blood Lipid Data Acquisition for Cardiovascular Disease Management in Internet of Medical Things

被引:20
作者
Huang, Xiwei [1 ]
Li, Yangbo [1 ]
Chen, Jin [1 ]
Liu, Jixuan [1 ]
Wang, Renjie [1 ]
Xu, Xuefeng [1 ]
Yao, Jiangfan [1 ]
Guo, Jinhong [2 ]
机构
[1] Hangzhou Dianzi Univ, Minist Educ, Key Lab RF Circuits & Syst, Hangzhou 310018, Zhejiang, Peoples R China
[2] Univ Elect Sci & Technol China, Sch Commun & Informat Engn, Chengdu 611731, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Blood lipid; photochemical; dongle; smartphone; Internet of Medical Things; DIAGNOSTICS RECENT DEVELOPMENTS; CELL DETECTION; CHOLESTEROL; SAMPLES; SYSTEM;
D O I
10.1109/ACCESS.2019.2922059
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With the ubiquitous deployment of smartphones worldwide recently, biomedical diagnostic devices based on smartphones are potential to be widely used for smart health management on the Internet of Medical Things (IoMT) applications under point-of-care (PoC) settings. Therefore, this paper introduces one smartphone-based blood lipid data acquisition dongle to monitor blood lipid level, including total cholesterol (TC), triglycerides (TG), and high-density lipoprotein cholesterol (HDL-C), using only a fingertip blood drop for cardiovascular disease management. During detection, a thin photochemical test strip that consists of LEDs and detectors is plugged into the compact dongle, where changed color intensities will indicate the lipid determinant concentration from the measured reflection coefficient of the chromogenic product. Such smartphone-based photochemical blood lipid data acquisition dongle was validated by comparing with a clinical analyzer, and reached a correlation coefficient over 0.903 and averaged coefficient of variation (CV)% of 4.575% for blood lipid measurement of 115 patients. The photochemical dongle is, therefore, promising for the future chronic disease management in the IoMT.
引用
收藏
页码:75276 / 75283
页数:8
相关论文
共 26 条
[1]   The evolution of selective analyses of HDL and LDL cholesterol in clinical and point of care testing [J].
Ahmadraji, Termeh ;
Killard, Anthony J. .
ANALYTICAL METHODS, 2013, 5 (15) :3612-3625
[2]   Mobile Phone-Based Microscopy, Sensing, and Diagnostics [J].
Contreras-Naranjo, Jose C. ;
Wei, Qingshan ;
Ozcan, Aydogan .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2016, 22 (03)
[3]   Multiplexed Point-of-Care Testing - xPOCT [J].
Dincer, Can ;
Bruch, Richard ;
Kling, Andre ;
Dittrich, Petra S. ;
Urban, Gerald A. .
TRENDS IN BIOTECHNOLOGY, 2017, 35 (08) :728-742
[4]  
Guo J., 2016, IEEE T EMERG TOP COM, V5, P518
[5]   Smartphone-Powered Electrochemical Dongle for Point-of-Care Monitoring of Blood β-Ketone [J].
Guo, Jinhong .
ANALYTICAL CHEMISTRY, 2017, 89 (17) :8609-8613
[6]   Simultaneous monitoring of glucose and uric acid on a single test strip with dual channels [J].
Guo, Jinhong ;
Ma, Xing .
BIOSENSORS & BIOELECTRONICS, 2017, 94 :415-419
[7]   On-Demand Lens less Single Cell Imaging Activated by Differential Resistive Pulse Sensing [J].
Guo, Jinhong ;
Huang, Xiwei ;
Ai, Ye .
ANALYTICAL CHEMISTRY, 2015, 87 (13) :6516-6519
[8]   Design of a Fluidic Circuit-Based Microcytometer for Circulating Tumor Cell Detection and Enumeration [J].
Guo, Jinhong ;
Lei, Wen ;
Ma, Xing ;
Xue, Peng ;
Chen, Yu ;
Kang, Yuejun .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2014, 8 (01) :35-41
[9]   Smartphone-based analytical biosensors [J].
Huang, Xiwei ;
Xu, Dandan ;
Chen, Jin ;
Liu, Jixuan ;
Li, Yangbo ;
Song, Jing ;
Ma, Xing ;
Guo, Jinhong .
ANALYST, 2018, 143 (22) :5339-5351
[10]   A Surface Acoustic Wave Pumped Lensless Microfluidic Imaging System for Flowing Cell Detection and Counting [J].
Huang, Xiwei ;
Farooq, Umar ;
Chen, Jin ;
Ge, Yakun ;
Gao, Haijun ;
Su, Jiangtao ;
Wang, Xiang ;
Dong, Shurong ;
Luo, Ji-Kui .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2017, 11 (06) :1478-1487