Systematic review on outcomes of acetabular revisions with highly-porous metals

被引:49
作者
Banerjee, Samik [1 ]
Issa, Kimona [1 ]
Kapadia, Bhaveen H. [1 ]
Pivec, Robert [1 ]
Khanuja, Harpal S. [1 ]
Mont, Michael A. [2 ]
机构
[1] Sinai Hosp, Ctr Joint Preservat & Replacement, Rubin Inst Adv Orthopaed, Dept Orthopaed Surg, Baltimore, MD 21215 USA
[2] Sinai Hosp, Ctr Joint Preservat & Replacement, Rubin Inst Adv Orthopaed, Baltimore, MD 21215 USA
关键词
Highly-porous; Revision; Arthroplasty; Hip; Outcomes; Review; TOTAL HIP-ARTHROPLASTY; HOST BONE CONTACT; CONCISE FOLLOW-UP; RHEUMATOID-ARTHRITIS; PELVIC DISCONTINUITY; HIGH PLACEMENT; DEFECTS; COMPONENT; TANTALUM; RECONSTRUCTION;
D O I
10.1007/s00264-013-2145-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to systematically review the literature and report the clinical and radiographic outcomes of highly-porous acetabular cups in revision settings. A literature search of four electronic databases of EMBASE, CINAHL-plus, PubMed, and SCOPUS yielded 25 studies reporting the outcomes of 2,083 revision procedures with highly-porous acetabular components. There was lack of high quality evidence (level I and level II studies) and only two studies with level III evidence, while the remainder were all level IV studies. In addition, a majority of the studies had small sample sizes and had short to mid-term follow-up. The mean age of the patients was 65 years (range, 58-72 years) and the mean follow-up was 3.6 years (range, two to six years). Outcomes evaluated were aseptic survivorship, Harris hip scores, migration rates, incidence of peri-acetabular radiolucencies and radiographic restoration of the hip centre. The mean aseptic survivorship was 97.2 % (range, 80-100 %). The Harris hip scores improved from a mean pre-operative score of 42 points, (range, 29-75 points), to a mean postoperative score of 79 points (range, 69-94 points). The mean incidence of cup migration and prevalence of peri-acetabular radiolucencies was 2.4 % (range, 0-8.8 %) and 4.6 % (range, 0-19 %), respectively, at final follow-up. The vertical hip centre-of-rotation was restored significantly from a mean of 39.2 mm (range, 27.6-50 mm) pre-operatively, to a mean of 24.1 mm (range, 7.4-47 mm), postoperatively. The short-term clinical and radiographic results of highly-porous metals in revision hip arthroplasty are excellent with a low rate of loosening in the presence of both major and minor bone loss.
引用
收藏
页码:689 / 702
页数:14
相关论文
共 64 条
[1]   Combined trabecular metal acetabular shell and augment for acetabular revision with substantial bone loss [J].
Abolghasemian, M. ;
Tangsataporn, S. ;
Sternheim, A. ;
Backstein, D. ;
Safir, O. ;
Gross, A. E. .
BONE & JOINT JOURNAL, 2013, 95B (02) :166-172
[2]  
Alfaro JJB, 2010, HIP INT, V20, pS119, DOI 10.5301/HIP.2010.5297
[3]  
Berry DJ, 2001, ORTHOPEDICS, V24, P881
[4]   Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial [J].
Bobyn, JD ;
Stackpool, GJ ;
Hacking, SA ;
Tanzer, M ;
Krygier, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :907-914
[5]   RESULTS OF REVISION FOR MECHANICAL FAILURE AFTER CEMENTED TOTAL HIP-REPLACEMENT, 1979 TO 1982 - A 2 TO 5-YEAR FOLLOW-UP [J].
CALLAGHAN, JJ ;
SALVATI, EA ;
PELLICCI, PM ;
WILSON, PD ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1074-1085
[6]   Acetabular revision with use of a bilobed component inserted without cement in patients who have acetabular bone-stock deficiency [J].
Chen, WM ;
Engh, CA ;
Hopper, RH ;
McAuley, JP ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (02) :197-206
[7]   Acetabular cup positioning in revision total hip arthroplasty with Paprosky type III acetabular defects: Martell radiographic analysis [J].
Choi, Ho-Rim ;
Anderson, David ;
Foster, Scott ;
Beal, Matthew ;
Lee, Jo Ann ;
Barr, Christopher ;
Malchau, Henrik ;
McCarthy, Joseph ;
Kwon, Young-Min .
INTERNATIONAL ORTHOPAEDICS, 2013, 37 (10) :1905-1910
[8]   Trabecular Metal Used for Major Bone Loss in Acetabular Hip Revision [J].
Davies, Jonah Hebert ;
Laflamme, G. Yves ;
Delisle, Josee ;
Fernandes, Julio .
JOURNAL OF ARTHROPLASTY, 2011, 26 (08) :1245-1250
[9]   Acetabular revision arthroplasty using so-called jumbo cementless components - An average 7-year follow-up study [J].
Dearborn, JT ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2000, 15 (01) :8-15
[10]   High placement of an acetabular component inserted without cement in a revision total hip arthroplasty - Results after a mean of ten years [J].
Dearborn, JT ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (04) :469-480