Study of a fluorometric-enzymatic method for bilirubin based on chemically modified bilirubin-oxidase and multivariate calibration

被引:51
作者
Andreu, Y
Ostra, M
Ubide, C
Galbán, J
de Marcos, S
Castillo, JR
机构
[1] Univ Zaragoza, GEAS, Fac Sci, Dept Analyt Chem, E-50009 Zaragoza, Spain
[2] Univ Basque Country, Fac Chem, Dept Appl Chem, San Sebastian, Spain
关键词
fluorometric-enzymatic; bilirubin; bilirubin-oxidase; chemically-modified;
D O I
10.1016/S0039-9140(02)00023-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The chemical derivatization of bilirubin oxidase (Box) with a fluorescein derivative (FS) yields a chemically modified enzyme (BOx-FS), with excitation and emission maxima at 487 and 520 nm, respectively. During the oxygen oxidation reaction of bilirubins, in the presence of the modified enzyme, the change in the fluorescence of the modified enzyme depends on the concentration and type of bilirubin. This effect can be used for analytical purposes. Firstly, a theoretical-experimental study of the analytical system was carried out. The mechanism responsible for the fluorescence variation was clarified, a mathematical model developed and the variables affecting the fluorescence changes optimized. The concentration ranges in which the model can be applied (up to 12 mg bilirubin 1(-1)), and the precision of the measurement (about 4%) were established for the three bilirubins. The application of the methodology to the simultaneous determination of direct and total bilirubins were studied by applying multivariate calibration methods to the whole kinetic profiles. A reduced calibration matrix (derived from a 53 base matrix) is proposed for calibration and different numerical methods were tested: Principal Components Regression (PCR), Partial Least Squares Regression (PLS) and Artificial Neural Networks (ANN). The simultaneous determination of direct and total bilirubin (average validation errors of about 9 and 10%, respectively) can be carried out from a single run. Furthermore, a semi-quantitative speciation of the three bilirubins (free, conjugated and albumin-bonded bilirubin) may be simultaneously obtained. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:343 / 353
页数:11
相关论文
共 20 条
[1]   Determination of direct-bilirubin by a fluorimetric-enzymatic method based on bilirubin oxidase [J].
Andreu, Y ;
Galbán, J ;
de Marcos, S ;
Castillo, JR .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (05) :516-521
[2]  
BOQUE R, 1994, AVANCES QUIMIOMETRIA, P176
[3]   Introduction to multivariate calibration in analytical chemistry [J].
Brereton, RG .
ANALYST, 2000, 125 (11) :2125-2154
[4]   Kinetic determinations and some kinetic aspects of analytical chemistry [J].
Crouch, SR ;
Scheeline, A ;
Kirkor, ES .
ANALYTICAL CHEMISTRY, 2000, 72 (12) :53R-70R
[5]   An optical glucose biosensor based on derived glucose oxidase immobilised onto a sol-gel matrix [J].
de Marcos, S ;
Galindo, J ;
Sierra, JF ;
Galbán, J ;
Castillo, JR .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 57 (1-3) :227-232
[6]  
DOUMAS BT, 1973, CLIN CHEM, V19, P984
[7]  
DOUMAS BT, 1985, CLIN CHEM, V31, P1677
[8]   Intrinsic fluorescence of enzymes and fluorescence of chemically modified enzymes for analytical purposes:: a review [J].
Galbán, J ;
Andreu, Y ;
Sierra, JF ;
de Marcos, S ;
Castillo, JR .
LUMINESCENCE, 2001, 16 (02) :199-210
[9]   Direct fluorometric determination of total cholesterol in serum using derivatized cholesterol oxidase [J].
Galbán, J ;
Sierra, JF ;
Sebastián, JML ;
de Marcos, S ;
Castillo, JR .
APPLIED SPECTROSCOPY, 2000, 54 (08) :1157-1162
[10]   INVESTIGATION OF THE USE OF BILIRUBIN OXIDASE TO MEASURE THE APPARENT UNBOUND BILIRUBIN CONCENTRATION IN HUMAN-PLASMA [J].
GOLDFINCH, ME ;
MAGUIRE, GA .
ANNALS OF CLINICAL BIOCHEMISTRY, 1988, 25 :73-77