Image-domain shading correction for cone-beam CT without prior patient information

被引:13
作者
Fan, Qiyong [1 ,2 ]
Lu, Bo [2 ]
Park, Justin C. [2 ]
Niu, Tianye [3 ,4 ]
Li, Jonathan G. [2 ]
Liu, Chihray [2 ]
Zhu, Lei [5 ,6 ]
机构
[1] Univ Nebraska Med Ctr, Dept Radiat Oncol, Omaha, NE USA
[2] Univ Florida, Dept Radiat Oncol, Gainesville, FL USA
[3] Zhejiang Univ, Sch Med, Sir Run Run Shaw Hosp, Hangzhou 310003, Zhejiang, Peoples R China
[4] Zhejiang Univ, Inst Translat Med, Hangzhou 310003, Zhejiang, Peoples R China
[5] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Nucl & Radiol Engn Program, Atlanta, GA 30332 USA
[6] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Med Phys Program, Atlanta, GA 30332 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2015年 / 16卷 / 06期
关键词
scatter correction; shading correction; CBCT; X-RAY SCATTER; ADAPTIVE RADIATION-THERAPY; COMPUTED-TOMOGRAPHY; CORRECTION ALGORITHM; PRIMARY MODULATION; SPREAD FUNCTION;
D O I
10.1120/jacmp.v16i6.5424
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In the era of high-precision radiotherapy, cone-beam CT (CBCT) is frequently utilized for on-board treatment guidance. However, CBCT images usually contain severe shading artifacts due to strong photon scatter from illumination of a large volume and non-optimized patient-specific data measurements, limiting the full clinical applications of CBCT. Many algorithms have been proposed to alleviate this problem by data correction on projections. Sophisticated methods have also been designed when prior patient information is available. Nevertheless, a standard, efficient, and effective approach with large applicability remains elusive for current clinical practice. In this work, we develop a novel algorithm for shading correction directly on CBCT images. Distinct from other image-domain correction methods, our approach does not rely on prior patient information or prior assumption of patient data. In CBCT, projection errors (mostly from scatter and non-ideal usage of bowtie filter) result in dominant low-frequency shading artifacts in image domain. In circular scan geometry, these artifacts often show global or local radial patterns. Hence, the raw CBCT images are first preprocessed into the polar coordinate system. Median filtering and polynomial fitting are applied on the transformed image to estimate the low-frequency shading artifacts (referred to as the bias field) angle-by-angle and slice-by-slice. The low-pass filtering process is done firstly along the angular direction and then the radial direction to preserve image contrast. The estimated bias field is then converted back to the Cartesian coordinate system, followed by 3D low-pass filtering to eliminate possible high-frequency components. The shading-corrected image is finally obtained as the uncorrected volume divided by the bias field. The proposed algorithm was evaluated on CBCT images of a pelvis patient and a head patient. Mean CT number values and spatial non-uniformity on the reconstructed images were used as image quality metrics. Within selected regions of interest, the average CT number error was reduced from around 300 HU to 42 and 38 HU, and the spatial nonuniformity error was reduced from above 17.5% to 2.1% and 1.7% for the pelvis and the head patients, respectively. As our method suppresses only low-frequency shading artifacts, patient anatomy and contrast were retained in the corrected images for both cases. Our shading correction algorithm on CBCT images offers several advantages. It has a high efficiency, since it is deterministic and directly operates on the reconstructed images. It requires no prior information or assumptions, which not only achieves the merits of CBCT-based treatment monitoring by retaining the patient anatomy, but also facilitates its clinical use as an efficient image-correction solution.
引用
收藏
页码:65 / 75
页数:11
相关论文
共 27 条
  • [1] CHARACTERIZATION OF THE POINT SPREAD FUNCTION AND MODULATION TRANSFER-FUNCTION OF SCATTERED RADIATION USING A DIGITAL IMAGING-SYSTEM
    BOONE, JM
    ARNOLD, BA
    SEIBERT, JA
    [J]. MEDICAL PHYSICS, 1986, 13 (02) : 254 - 256
  • [2] AN ANALYTICAL MODEL OF THE SCATTERED RADIATION DISTRIBUTION IN DIAGNOSTIC-RADIOLOGY
    BOONE, JM
    SEIBERT, JA
    [J]. MEDICAL PHYSICS, 1988, 15 (05) : 721 - 725
  • [3] Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy
    Brunner, Stephen
    Nett, Brian E.
    Tolakanahalli, Ranjini
    Chen, Guang-Hong
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04) : 1015 - 1030
  • [4] Accelerated simulation of cone beam X-ray scatter projections
    Colijn, AP
    Beekman, FJ
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (05) : 584 - 590
  • [5] Formulating adaptive radiation therapy (ART) treatment planning into a closed-loop control framework
    de la Zerda, Adam
    Armbruster, Benjamin
    Xing, Lei
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (14) : 4137 - 4153
  • [6] Scatter correction method for x-ray CT using primary modulation: Phantom studies
    Gao, Hewei
    Fahrig, Rebecca
    Bennett, N. Robert
    Sun, Mingshan
    Star-Lack, Josh
    Zhu, Lei
    [J]. MEDICAL PHYSICS, 2010, 37 (02) : 934 - 946
  • [7] Cone beam computerized tomography: the effect of calibration of the Hounsfield unit number to electron density on dose calculation accuracy for adaptive radiation therapy
    Hatton, Joan
    McCurdy, Boyd
    Greer, Peter B.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15) : N329 - N346
  • [8] GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation
    Jia, Xun
    Lou, Yifei
    Li, Ruijiang
    Song, William Y.
    Jiang, Steve B.
    [J]. MEDICAL PHYSICS, 2010, 37 (04) : 1757 - 1760
  • [9] Technical note: comparing coherent and incoherent scatter effects for cone-beam CT
    Kyriakou, Yiannis
    Meyer, Michael
    Kalender, Willi A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (10) : N175 - N185
  • [10] Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT
    Kyriakou, Yiannis
    Riedel, Thomas
    Kalender, Willi A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (18) : 4567 - 4586