Micro-CT of rodents: State-of-the-art and future perspectives

被引:171
作者
Clark, D. P. [1 ]
Badea, C. T. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Ctr Vivo Microscopy, Durham, NC 27710 USA
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2014年 / 30卷 / 06期
关键词
Micro-CT; X-ray; Rodents; Heart; Tumors; Lung; Bone; Nanoparticles; RESOLUTION COMPUTED-TOMOGRAPHY; CONE-BEAM CT; IN-VIVO; IMAGE-RECONSTRUCTION; GOLD NANOPARTICLES; BONE ARCHITECTURE; CONTRAST AGENT; ATTENUATION CORRECTION; PULMONARY COMPLIANCE; MICROCOMPUTED TOMOGRAPHY;
D O I
10.1016/j.ejmp.2014.05.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Micron-scale computed tomography (micro-CT) is an essential tool for phenotyping and for elucidating diseases and their therapies. This work is focused on preclinical micro-CT imaging, reviewing relevant principles, technologies, and applications. Commonly, micro-CT provides high-resolution anatomic information, either on its own or in conjunction with lower-resolution functional imaging modalities such as positron emission tomography (PET) and single-photon emission computed tomography (SPECT). More recently, however, advanced applications of micro-CT produce functional information by translating clinical applications to model systems (e.g. measuring cardiac functional metrics) and by pioneering new ones (e.g. measuring tumor vascular permeability with nanoparticle contrast agents). The primary limitations of micro-CT imaging are the associated radiation dose and relatively poor soft tissue contrast. We review several image reconstruction strategies based on iterative, statistical, and gradient sparsity regularization, demonstrating that high image quality is achievable with low radiation dose given ever more powerful computational resources. We also review two contrast mechanisms under intense development. The first is spectral contrast for quantitative material discrimination in combination with passive or actively targeted nanoparticle contrast agents. The second is phase contrast which measures refraction in biological tissues for improved contrast and potentially reduced radiation dose relative to standard absorption imaging. These technological advancements promise to develop micro-CT into a commonplace, functional and even molecular imaging modality. (C) 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:619 / 634
页数:16
相关论文
共 193 条
[1]   In-vivo high-resolution X-ray microtomography for liver and spleen tumor assessment in mice [J].
Almajdub, M. ;
Nejjari, M. ;
Poncet, G. ;
Magnier, L. ;
Chereul, E. ;
Roche, C. ;
Janier, M. .
CONTRAST MEDIA & MOLECULAR IMAGING, 2007, 2 (02) :88-93
[2]  
[Anonymous], SCI REPORTS
[3]   Forced mobilization accelerates pathogenesis: characterization of a preclinical surgical model of osteoarthritis [J].
Appleton, C. Thomas G. ;
McErlain, David D. ;
Pitelka, Vasek ;
Schwartz, Neil ;
Bernier, Suzanne M. ;
Henry, James L. ;
Holdsworth, David W. ;
Beier, Frank .
ARTHRITIS RESEARCH & THERAPY, 2007, 9 (01)
[4]   Least-error projection sorting to optimize retrospectively gated cardiac micro-CT of free-breathing mice [J].
Armitage, Stephen E. J. ;
Pollmann, Steven I. ;
Detombe, Sarah A. ;
Drangova, Maria .
MEDICAL PHYSICS, 2012, 39 (03) :1452-1461
[5]   Dual-Energy Micro-CT Functional Imaging of Primary Lung Cancer in Mice Using Gold and Iodine Nanoparticle Contrast Agents: A Validation Study [J].
Ashton, Jeffrey R. ;
Clark, Darin P. ;
Moding, Everett J. ;
Ghaghada, Ketan ;
Kirsch, David G. ;
West, Jennifer L. ;
Badea, Cristian T. .
PLOS ONE, 2014, 9 (02)
[6]   Anatomical and functional imaging of myocardial infarction in mice using micro-CT and eXIA 160 contrast agent [J].
Ashton, Jeffrey R. ;
Befera, Nicholas ;
Clark, Darin ;
Qi, Yi ;
Mao, Lan ;
Rockman, Howard A. ;
Johnson, G. Allan ;
Badea, Cristian T. .
CONTRAST MEDIA & MOLECULAR IMAGING, 2014, 9 (02) :161-168
[7]   Micro-CT with respiratory and cardiac gating [J].
Badea, C ;
Hedlund, LW ;
Johnson, GA .
MEDICAL PHYSICS, 2004, 31 (12) :3324-3329
[8]  
Badea C, 2014, SPIE MED IMAGING, V9038
[9]  
Badea C., 2005, MOL IMAGING, V4, P110
[10]   In vivo small-animal imaging using micro-CT and digital subtraction angiography [J].
Badea, C. T. ;
Drangova, M. ;
Holdsworth, D. W. ;
Johnson, G. A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (19) :R319-R350