Complex dark-field contrast and its retrieval in x-ray phase contrast imaging implemented with Talbot interferometry

被引:3
作者
Yang, Yi [1 ]
Tang, Xiangyang [1 ]
机构
[1] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
关键词
x-ray differential phase contrast imaging; x-ray Talbot interferometry; x-ray dark-field imaging; x-ray phase contrast CT; complex dark-field contrast; phase-attenuation duality; COMPUTED-TOMOGRAPHY; SIGNAL; GRATINGS;
D O I
10.1118/1.4896098
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Under the existing theoretical framework of x-ray phase contrast imaging methods implemented with Talbot interferometry, the dark-field contrast refers to the reduction in interference fringe visibility due to small-angle x-ray scattering of the subpixel microstructures of an object to be imaged. This study investigates how an object's subpixel microstructures can also affect the phase of the intensity oscillations. Methods: Instead of assuming that the object's subpixel microstructures distribute in space randomly, the authors' theoretical derivation starts by assuming that an object's attenuation projection and phase shift vary at a characteristic size that is not smaller than the period of analyzer grating G(2) and a characteristic length d(c). Based on the paraxial Fresnel-Kirchhoff theory, the analytic formulae to characterize the zeroth- and first-order Fourier coefficients of the x-ray irradiance recorded at each detector cell are derived. Then the concept of complex dark-field contrast is introduced to quantify the influence of the object's microstructures on both the interference fringe visibility and the phase of intensity oscillations. A method based on the phase-attenuation duality that holds for soft tissues and high x-ray energies is proposed to retrieve the imaginary part of the complex dark-field contrast for imaging. Through computer simulation study with a specially designed numerical phantom, they evaluate and validate the derived analytic formulae and the proposed retrieval method. Results: Both theoretical analysis and computer simulation study show that the effect of an object's subpixel microstructures on x-ray phase contrast imaging method implemented with Talbot interferometry can be fully characterized by a complex dark-field contrast. The imaginary part of complex dark-field contrast quantifies the influence of the object's subpixel microstructures on the phase of intensity oscillations. Furthermore, at relatively high energies, for soft tissues it can be retrieved for imaging with a method based on the phase-attenuation duality. Conclusions: The analytic formulae derived in this work to characterize the complex dark-field contrast in x-ray phase contrast imaging method implemented with Talbot interferometry are of significance, which may initiate more activities in the research and development of x-ray differential phase contrast imaging for extensive biomedical applications. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] X-ray dark-field tomography of fresh biological samples with the grating interferometry
    Jiang, Xiaolei
    Zhang, Li
    Zhang, Ran
    Zhu, Xiaohua
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [32] Optimization of contrast and dose in x-ray phase-contrast tomography with a Talbot-Lau interferometer
    Makinen, Henrik
    Suhonen, Heikki
    Siiskonen, Teemu
    David, Christian
    Huotari, Simo
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (04):
  • [33] Choosing sensitivity to reduce X-ray dose in medical phase contrast imaging
    Preusche, Oliver
    OPTICS EXPRESS, 2018, 26 (08): : 10339 - 10357
  • [34] Phase-contrast X-ray imaging of breast
    Keyrilainen, Jani
    Bravin, Alberto
    Fernandez, Manuel
    Tenhunen, Mikko
    Virkkunen, Pekka
    Suortti, Pekka
    ACTA RADIOLOGICA, 2010, 51 (08) : 866 - 884
  • [35] Evaluation of microbubble contrast agents for dynamic imaging with x-ray phase contrast
    Millard, T. P.
    Endrizzi, M.
    Everdell, N.
    Rigon, L.
    Arfelli, F.
    Menk, R. H.
    Stride, E.
    Olivo, A.
    SCIENTIFIC REPORTS, 2015, 5
  • [36] Improving contrast and spatial resolution in crystal analyzer-based x-ray dark-field imaging: Theoretical considerations and experimental demonstration
    Ando, Masami
    Nakao, Yuki
    Jin, Ge
    Sugiyama, Hiroshi
    Sunaguchi, Naoki
    Sung, Yongjin
    Suzuki, Yoshifumi
    Sun, Yong
    Tanimoto, Michio
    Kawashima, Katsuhiro
    Yuasa, Tetsuya
    Mori, Kensaku
    Ichihara, Shu
    Gupta, Rajiv
    MEDICAL PHYSICS, 2020, 47 (11) : 5505 - 5513
  • [37] X-ray dark-field imaging for detection of foreign bodies in food
    Nielsen, Mikkel Schou
    Lauridsen, Torsten
    Christensen, Lars Bager
    Feidenhans'l, Robert
    FOOD CONTROL, 2013, 30 (02) : 531 - 535
  • [38] Development of X-ray dark-field imaging towards clinical application
    ANDO Masami
    HASHIMOTO Eiko
    HASHIZUME Hiroyuki
    HYODO Kazuyuki
    INOUE Hajime
    ISHIKAWA Tetsuya
    KUNISADA Toshiyuki
    MAKSIMENKO Anton
    PATTANASIRIWISAWA Wanwisa
    RUBENSTEIN Edward
    ROBERSON Joseph
    SHIMAO Daisuke
    SUGIYAMA Hiroshi
    TAKEDA Ken
    UENO Ei
    WADA Hiroshi
    Nuclear Science and Techniques, 2004, (03) : 129 - 139
  • [39] A new optics for dark-field imaging in X-ray region 'Owl'
    Ando, M
    Sugiyama, H
    Maksimenko, A
    Pattanasiriwisawa, W
    Hyodo, K
    Zhang, XW
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2001, 40 (8A): : L844 - L846
  • [40] Dark-field signal extraction in propagation-based phase-contrast imaging
    Gureyev, T. E.
    Paganin, D. M.
    Arhatari, B.
    Taba, S. T.
    Lewis, S.
    Brennan, P. C.
    Quiney, H. M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (21)