Diagnostic effect of capsule endoscopy in 31 cases of subacute small bowel obstruction

被引:28
作者
Yang, Xiao-Yun [1 ]
Chen, Chun-Xiao [1 ]
Zhang, Bing-Ling [1 ]
Yang, Li-Ping [1 ]
Su, Hua-Ling [1 ]
Teng, Li-Song [2 ]
Li, You-Ming [1 ]
机构
[1] Zhejiang Univ, Affiliated Hosp 1, Coll Med, Dept Gastroenterol, Hangzhou 310003, Zhejiang, Peoples R China
[2] Zhejiang Univ, Affiliated Hosp 1, Coll Med, Dept Oncol, Hangzhou 310003, Zhejiang, Peoples R China
关键词
Capsule endoscopy; Small bowel obstruction; Capsule retention; PATENCY CAPSULE; PUSH ENTEROSCOPY; CROHNS-DISEASE; RETENTION; EXPERIENCE; STENOSIS; SYSTEM; RISK;
D O I
10.3748/wjg.15.2401
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM: To evaluate the effectiveness and safety of capsule endoscopy (CE) in patients with recurrent subacute small bowel obstruction. METHODS: The study was a retrospective analysis of 31 patients referred to hospital from January 2003 to August 2008 for the investigation of subacute small bowel obstruction, who underwent CE. The patients were aged 9-81 years, and all of them had undergone gastroscopy and colonoscopy previously. Some of them received abdominal computed tomography or small bowel follow-through. RESULTS: CE made a definitive diagnosis in 12 (38.7%) of 31 cases: four Crohn's disease (CD), two carcinomas, one intestinal tuberculosis, one ischemic enteritis, one abdominal cocoon, one duplication of the intestine, one diverticulum and one ileal polypoid tumor. Capsule retention occurred in three (9.7%) of 31 patients, and was caused by CD (2) or tumor (1). Two with retained capsules were retrieved at surgery, and the other one of the capsules was spontaneously passed the stricture by medical treatment in 6 mo. No case had an acute small bowel obstruction caused by performance of CE. CONCLUSION: CE provided safe and effective visualization to identify the etiology of a subacute small bowel obstruction, especially in patients with suspected intestinal tumors or CD, which are not identified by routine examinations. (C) 2009 The WJG Press and Baishideng. All rights reserved,
引用
收藏
页码:2401 / 2405
页数:5
相关论文
共 18 条
  • [1] Wireless Capsule Endoscopy requiring surgical intervention: The world's experience
    Barkin, JS
    Friedman, S
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2002, 97 (09) : S298 - S298
  • [2] Does passage of a patency capsule indicate small-bowel patency? A prospective clinical trial?
    Boivin, ML
    Lochs, H
    Voderholzer, WA
    [J]. ENDOSCOPY, 2005, 37 (09) : 808 - 815
  • [3] ICCE consensus for capsule retention
    Cave, D
    Legnani, P
    de Franchis, R
    Lewis, BS
    [J]. ENDOSCOPY, 2005, 37 (10) : 1065 - 1067
  • [4] The risk of retention of the capsule endoscope in patients with known or suspected Crohn's disease
    Cheifetz, Adam S.
    Kornbluth, Asher A.
    Legnani, Peter
    Schmelkin, Ira
    Brown, Alphonso
    Lichtiger, Simon
    Lewis, Blair S.
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2006, 101 (10) : 2218 - 2222
  • [5] Capsule endoscopy retention: Is it a complication?
    Cheifetz, Adam S.
    Lewis, Blair S.
    [J]. JOURNAL OF CLINICAL GASTROENTEROLOGY, 2006, 40 (08) : 688 - 691
  • [6] CHEIFETZ SA, 2004, GASTROINTEST ENDOSC, V59, pAB461
  • [7] Clinical evaluation of the use of the M2A patency capsule system before a capsule endoscopy procedure, in patients with known or suspected intestinal stenosis
    Delvaux, M
    Ben Soussan, E
    Laurent, V
    Lerebours, E
    Gay, G
    [J]. ENDOSCOPY, 2005, 37 (09) : 801 - 807
  • [8] Ge ZZ, 2004, CHINESE MED J-PEKING, V117, P1045
  • [9] Small bowel: Preliminary comparison of capsule endoscopy with barium study and CT
    Hara, AK
    Leighton, JA
    Sharma, VK
    Fleischer, DE
    [J]. RADIOLOGY, 2004, 230 (01) : 260 - 265
  • [10] Agile patency system eliminates risk of capsule retention in patients with known intestinal strictures who undergo capsule endoscopy
    Herrerias, Juan M.
    Leighton, Jonathan A.
    Costamagna, Guido
    Infantolino, Anthony
    Eliakim, Rami
    Fischer, Doron
    Rubin, David T.
    Manten, Howard D.
    Scapa, Eitan
    Morgan, Douglas R.
    Bergwerk, Ari J.
    Koslowsky, Binyamin
    Adler, Samuel N.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2008, 67 (06) : 902 - 909