Development of catheters with low fiber background signals for Raman spectroscopic diagnosis applications

被引:22
作者
de Lima, CJ [1 ]
Sathaiah, S [1 ]
Silveira, L [1 ]
Zângaro, RA [1 ]
Pacheco, MTT [1 ]
机构
[1] UNIVAP, Inst Pesquisas & Desenvolvimento, BR-12244400 Sao Jose Dos Campos, Brazil
关键词
multifiber catheters; fiber optics;
D O I
10.1046/j.1525-1594.2000.06525.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Utilization of optical-fiber catheters can turn the Raman spectroscopy system into a powerful remote biomedical diagnostic probe. An in vivo (a qualitative and a quantitative) biochemical diagnosis of biotissues is possible by developing the Raman-fiber probes with a good flexibility and less background signals generated in the probes themselves. Considering the isotropic nature of Raman scattering, the amount of Raman signal guided through the fiber is expected to depend on the numerical aperture (NA) of the fiber. To study the dependence for catheter probes experimentally, various flexible probes (with small diameter fibers) with different combinations of numerical apertures and with different assembling materials (biocompatible) have been developed. The catheter probes have been characterized by collecting the near infrared excited Raman scattered light from cholesterol powder. The results demonstrate that the catheters with a combination of lower NA (0.12) fibers used for laser excitation and relatively higher NA (0.22) fibers for Raman signal collection will have lower background signals generated in the probes. Furthermore, the catheters with a black Teflon tubing cover and black epoxy resin adhesives were found to give better results.
引用
收藏
页码:231 / 234
页数:4
相关论文
共 13 条
  • [1] RAMAN-SPECTROSCOPY OVER OPTICAL FIBERS WITH THE USE OF A NEAR-IR FT SPECTROMETER
    ARCHIBALD, DD
    LIN, LT
    HONIGS, DE
    [J]. APPLIED SPECTROSCOPY, 1988, 42 (08) : 1558 - 1563
  • [2] PORTABLE LASER SPECTROFLUOROMETER SYSTEM FOR IN-VIVO HUMAN TISSUE FLUORESCENCE STUDIES
    BRENNAN, JF
    ZONIOS, GI
    WANG, TD
    RAVA, RP
    HAYES, GB
    DASARI, RR
    FELD, MS
    [J]. APPLIED SPECTROSCOPY, 1993, 47 (12) : 2081 - 2086
  • [3] Chavantes MC, 1997, VATS '97: IV INTERNATIONAL SYMPOSIUM ON THORACOSCOPY & VIDEO ASSISTED THORACIC SURGERY, P89
  • [4] CHAVANTES MC, 1996, LASER SURG MED, V8, P1
  • [5] CHONG CK, 1992, VIB SPECTROSC, V3, P35, DOI 10.1016/0924-2031(92)85022-S
  • [6] DALY JC, 1984, FIBER OPTICS, V3, P70
  • [7] QUANTITATIVE DETECTION OF ENVIRONMENTALLY IMPORTANT DYES USING DIODE LASER/FIBER-OPTIC RAMAN-SPECTROSCOPY
    GILMORE, DA
    GURKA, D
    DENTON, MB
    [J]. APPLIED SPECTROSCOPY, 1995, 49 (04) : 508 - 512
  • [8] GIOZZA WF, 1991, FIBRAS OPTICAS TECHN
  • [9] REMOTE BIOMEDICAL SPECTROSCOPIC IMAGING OF HUMAN ARTERY WALL
    HOYT, CC
    RICHARDSKORTUM, RR
    COSTELLO, B
    SACKS, BA
    KITTRELL, C
    RATLIFF, NB
    KRAMER, JR
    FELD, MS
    [J]. LASERS IN SURGERY AND MEDICINE, 1988, 8 (01) : 1 - 9
  • [10] IAN RL, 1996, APPL SPEC, V50, pA12