An Islanding Detection Algorithm for Inverter-Based Distributed Generation Based on Reactive Power Control

被引:86
作者
Chen, Xiaolong [1 ]
Li, Yongli [1 ]
机构
[1] Tianjin Univ, Dept Elect Engn & Automat, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
Inverter-based distributed generation; islanding detection; power factor improvement; reactive power control strategy; voltage regulation; SYSTEMS;
D O I
10.1109/TPEL.2013.2284236
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For the inverter-based distributed generation (DG) under constant power control, this paper analyzes the relationship between the active/reactive power mismatch and frequency deviation, respectively, during islanding and finds that the frequency variation trends caused by active and reactive power mismatches may be opposite. In order to eliminate the nondetection zone (NDZ) and detect islanding rapidly, an innovative islanding detection algorithm is presented based on a reactive power control strategy. The strategy provides the reactive power reference for the DG to guarantee the consistency of the frequency variation trends caused by both active and reactive power mismatches, thus accelerating the islanding detection speed. In addition, the introduction of the voltage variation into the proposed reactive power control strategy can regulate voltage dynamically in grid-connected mode and further shorten the islanding detection time as well. According to the antiislanding test system in the IEEE Std. 929-2000 and IEEE Std. 1547-2003, several case studies are carried out in the power systems computer-aided design/EMTDC environment. The simulation results show that the proposed algorithm has the zero NDZ property and can detect islanding rapidly. Moreover, the algorithm also performs effectively for load imbalance conditions as well as for the system with multiple DGs.
引用
收藏
页码:4672 / 4683
页数:12
相关论文
共 29 条
[1]  
[Anonymous], 2000, 929 IEEE
[2]  
[Anonymous], 2003, 15472003 IEEE
[3]   Control for Grid-Connected and Intentional Islanding Operations of Distributed Power Generation [J].
Balaguer, Irvin J. ;
Lei, Qin ;
Yang, Shuitao ;
Supatti, Uthane ;
Peng, Fang Zheng .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (01) :147-157
[4]   Control strategy for grid-connected DC-AC converters with load power factor correction [J].
Barbosa, PG ;
Rolim, LGB ;
Watanabe, EH ;
Hanitsch, R .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1998, 145 (05) :487-491
[5]  
Barker PP, 2000, 2000 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, CONFERENCE PROCEEDINGS, VOLS 1-4, P1645, DOI 10.1109/PESS.2000.868775
[6]  
De Mango F., 2006, 12th International Power Electronics & Motion Control Conference (IEEE Cat. No.06EX1282C), P1878
[7]  
De Mango F., 2006, 12th International Power Electronics & Motion Control Conference (IEEE Cat. No.06EX1282C), P1884
[8]   Evaluation of the Voltage Support Strategies for the Low Voltage Grid Connected PV Generators [J].
Demirok, Erhan ;
Sera, Dezso ;
Teodorescu, Remus ;
Rodriguez, Pedro ;
Borup, Uffe .
2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, :710-717
[9]   Performance Evaluation of Active Islanding-Detection Algorithms in Distributed-Generation Photovoltaic Systems: Two Inverters Case [J].
Estebanez, Emilio J. ;
Moreno, Victor M. ;
Pigazo, Alberto ;
Liserre, Marco ;
Dell'Aquila, Antonio .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (04) :1185-1193
[10]   Design and operation of grid-connected photovoltaic system with power-factor control and active islanding detection [J].
Huang, SJ ;
Pai, FS .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2001, 148 (03) :243-250