Continuous High-Frequency Dissolved O2/Ar Measurements by Equilibrator Inlet Mass Spectrometry

被引:101
|
作者
Cassar, Nicolas [1 ]
Barnett, Bruce A. [1 ]
Bender, Michael L. [1 ]
Kaiser, Jan [2 ]
Hamme, Roberta C. [3 ]
Tilbrook, Bronte [4 ,5 ]
机构
[1] Princeton Univ, Dept Geosci, Princeton, NJ 08544 USA
[2] Univ E Anglia, Sch Environm Sci, Norwich NR4 7TJ, Norfolk, England
[3] Univ Victoria, Sch Earth & Ocean Sci, Victoria, BC V8W 3P6, Canada
[4] CSIRO, Wealth Oceans Res Program, Hobart, Tas 7001, Australia
[5] CSIRO, Antarctic Climate & Ecosyst Cooperat Res Ctr, Hobart, Tas 7001, Australia
关键词
TRIPLE ISOTOPE COMPOSITION; SOUTHERN-OCEAN; GAS-EXCHANGE; DIFFUSION COEFFICIENTS; MEMBRANE CONTACTORS; METABOLIC BALANCE; WIND-SPEED; OXYGEN; WATER; SEA;
D O I
10.1021/ac802300u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The oxygen (O-2) concentration in the surface ocean is influenced by biological and physical processes. With concurrent measurements of argon (Ar), which has similar solubility properties as oxygen, we can remove the physical contribution to O-2 supersdturation and determine the biological oxygen supersaturation. Biological O-2 supersaturation in the surface ocean reflects the net metabolic balance between photosynthesis and respiration, i.e., the net community productivity (NCP). We present a new method for continuous shipboard measurements of O-2/Ar by equilibrator inlet mass spectrometry (EIMS). From these measurements and an appropriate gas exchange parametrization, NCP can be estimated at high spatial and temporal resolution. In the EIMS configuration, seawater from the ship's continuous intake flows through a cartridge enclosing a gas-permeable microporous membrane contactor. Gases in the headspace of the cartridge equilibrate with dissolved gases in the flowing seawater. A fused-silica capillary continuously samples headspace gases, and the O-2/Ar ratio is measured by mass spectrometry. The ion current measurements on the mass spectrometer reflect the partial pressures of dissolved gases in the water flowing through the equilibrator. Calibration of the O-2/Ar ion current ratio (32/40) is performed automatically every 2 h by sampling ambient air through a second capillary. A conceptual model demonstrates that the ratio of gases reaching the mass spectrometer is dependent on several parameters, such as the differences in molecular diffusivities and solubilities of the gases. Laboratory experiments and field observations performed by EIMS are discussed. We also present preliminary evidence that other gas measurements, such as N-2/Ar and PCO2 measurements, may potentially be performed with EIMS. Finally, we compare the characteristics of the EIMS with the previously described membrane inlet mass spectrometry (MIMS) approach.
引用
收藏
页码:1855 / 1864
页数:10
相关论文
共 50 条
  • [1] Marine productivity estimates from continuous O2/Ar ratio measurements by membrane inlet mass spectrometry -: art. no. L19605
    Kaiser, J
    Reuer, MK
    Barnett, B
    Bender, ML
    GEOPHYSICAL RESEARCH LETTERS, 2005, 32 (19) : 1 - 5
  • [2] High-resolution measurement of Southern Ocean CO2 and O2/Ar by membrane inlet mass spectrometry
    Gueguen, C.
    Tortell, P. D.
    MARINE CHEMISTRY, 2008, 108 (3-4) : 184 - 194
  • [3] Continuous shipboard sampling system for determination of triple oxygen isotopes and O2/Ar ratio by dual-inlet mass spectrometry
    Sarma, V. V. S. S.
    Abe, O.
    Yoshida, N.
    Saino, T.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (23) : 3503 - 3508
  • [4] Optical and mass spectrometric measurements of dissociation in low frequency, high density, remote source O2/Ar and NF3/Ar plasmas
    Li, Hanyang
    Zhou, Yingliang
    Donnelly, Vincent M.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2020, 38 (02):
  • [5] Dissolved gas measurements in oceanic waters made by membrane inlet mass spectrometry
    Tortell, PD
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2005, 3 : 24 - 37
  • [6] Evaluating O2 : Ar, N2 : Ar, and 29,30N2 using membrane inlet mass spectrometry configured to minimize oxygen interference
    Boedecker, Ashlynn R.
    Taylor, Jason M.
    Tappenbeck, Tyler H.
    Hall Jr, Robert O.
    Robbins, Caleb J.
    Scott, J. Thad
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2024, 22 (11): : 791 - 804
  • [7] Continuous measurements of dissolved O2 and oxygen isotopes in the Southern California coastal ocean
    Rafelski, Lauren Elmegreen
    Paplawsky, Bill
    Keeling, Ralph F.
    MARINE CHEMISTRY, 2015, 174 : 94 - 102
  • [8] Reaction of water at hot filament interferes with measurements of dissolved gases by membrane inlet mass spectrometry
    Orsnes, H
    Bohatka, S
    Degn, H
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1997, 11 (15) : 1736 - 1738
  • [9] Threshold ionization mass spectrometry measurements of neutral density in dual frequency SF6/O2 plasmas
    Jaiprakash, VC
    Thompson, BE
    PLASMA PROCESSING XII, 1998, 98 (04): : 101 - 113
  • [10] Mass spectrometry at a Ar/SF6/O2 chemically reactive plasma jet
    Arnold, Th.
    Schindler, A.
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2008, 205 (04): : 957 - 960