Performance of electronic portal imaging devices (EPIDs) used in radiotherapy:: Image quality and dose measurements

被引:46
作者
Cremers, F [1 ]
Frenzel, T [1 ]
Kausch, C [1 ]
Albers, D [1 ]
Schönborn, T [1 ]
Schmidt, R [1 ]
机构
[1] Univ Hamburg Hosp, Clin Radiotherapy & Radiooncol, D-20246 Hamburg, Germany
关键词
portal imaging; image quality; amorphous silicon array; fluoroscopic portal imaging system; response; dosimetry; radiation therapy;
D O I
10.1118/1.1688212
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of our Study was to compare the image and dosimetric quality of two different imaging systems. The first one is a fluoroscopic electronic portal imaging device (first generation), while the second is based on an amorphous silicon flat-panel array (second generation). The parameters describing image quality include spatial resolution [modulation transfer function (MTF)], noise [noise power spectrum (NPS)], and signal-to-noise transfer [detective quantum efficiency (DQE)]. The dosimetric measurements were compared with ionization chamber as well as with film measurements. The response of the flat-panel imager and the fluoroscopic-optical device was determined performing a two-step Monte Carlo simulation. All measurements were performed in a 6 MV linear accelerator photon beam. The resolution (MTF) of the fluoroscopic device (f(1/2) = 0.3 mm(-1)) is larger than of the amorphous silicon based system (f(1/2) = 0.21 mm(-1)), which is due to the missing backscattered photons and the smaller pixel size. The noise measurements (NPS) show the correlation of neighboring pixels of the amorphous silicon electronic portal imaging device, whereas the NPS of the fluoroscopic system is frequency independent. At zero spatial frequency the DQE of the flat-panel imager has a value of 0.008 (0.8%). Due to the minor frequency dependency this device may be almost x-ray quantum limited. Monte Carlo simulations verified these characteristics. For the fluoroscopic imaging system the DQE at low frequencies is about 0.0008 (0.08%) and degrades with higher frequencies. Dose measurements with the flat-panel imager revealed that images can only be directly converted to portal dose images, if scatter can be neglected. Thus objects distant to the detector (e.g., inhomogeneous dose distribution generated by a modificator) can be verified dosimetrically, while objects close to a detector (e.g., a patient) cannot be verified directly and must be scatter corrected prior to verification. This is justified by the response of the flat-panel imaging device revealing a strong dependency at low energies. (C) 2004 American Association of PhYsicists in Medicine.
引用
收藏
页码:985 / 996
页数:12
相关论文
共 50 条
[1]  
Beauchamp K. G, 1979, DIGITAL METHODS SIGN
[2]   A quantum accounting and detective quantum efficiency analysis for video-based portal imaging [J].
Bissonnette, JP ;
Cunningham, IA ;
Jaffray, DA ;
Fenster, A ;
Munro, P .
MEDICAL PHYSICS, 1997, 24 (06) :815-826
[3]   Optimal phosphor thickness for portal imaging [J].
Bissonnette, JP ;
Cunningham, IA ;
Munro, P .
MEDICAL PHYSICS, 1997, 24 (06) :803-814
[4]   OPTIMAL RADIOGRAPHIC MAGNIFICATION FOR PORTAL IMAGING [J].
BISSONNETTE, JP ;
JAFFRAY, DA ;
FENSTER, A ;
MUNRO, P .
MEDICAL PHYSICS, 1994, 21 (09) :1435-1445
[5]   A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS) [J].
BOYER, AL ;
ANTONUK, L ;
FENSTER, A ;
VANHERK, M ;
MEERTENS, H ;
MUNRO, P ;
REINSTEIN, LE ;
WONG, J .
MEDICAL PHYSICS, 1992, 19 (01) :1-16
[6]  
CREMERS F, 2000, P MONT CARL 2000 C L
[7]  
Dainty JC., 1974, IMAGE SCI
[8]   A prototype amorphous silicon array based radiotherapy portal imager [J].
Drake, DG ;
Jaffray, DA ;
Wong, JW .
PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 :32-41
[9]   Characteristics of metal-plate/film detectors at therapy energies. II. Detective quantum efficiency [J].
Falco, T ;
Fallone, BG .
MEDICAL PHYSICS, 1998, 25 (12) :2463-2468
[10]   Characteristics of metal-plate/film detectors at therapy energies. I. Modulation transfer function [J].
Falco, T ;
Fallone, BG .
MEDICAL PHYSICS, 1998, 25 (12) :2455-2462