Analysis of gangliosides by capillary zone electrophoresis and capillary zone electrophoresis electrospray mass spectrometry

被引:0
|
作者
Ju, DD [1 ]
Lai, CC [1 ]
Her, GR [1 ]
机构
[1] NATL TAIWAN UNIV, DEPT CHEM, TAIPEI 10764, TAIWAN
关键词
buffer composition; detection; electrophoresis; gangliosides; glycosphingolipids; lipids;
D O I
暂无
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gangliosides, sialic acid(s)-containing glycosphingolipids, were separated by capillary zone electrophoresis and detected with either UV or electrospray mass spectrometry. Several electrolyte systems were evaluated for the separation of underivatized gangliosides. The best result was obtained by using 50 mM borate and 50 mM phosphate buffer containing 20 mM alpha-cyclodextrin at pH 9.9. The four major ganglioside forms (GM1, GD1a, GT1b, GT1b) were successfully separated, and, moreover, each ganglioside yielded two peaks, splitting by the difference in chain length of the ceramide moiety. The resolution obtained in CE-UV could not be reproduced in CE-MS because of the incompatibility of the borate/phosphate buffer to ESI-MS. With the use of more volatile buffers, such as ammonium acetate or 2-[N-cyclohexylamino]-ethanesulfonic acid, baseline resolution was obtained for gangliosides having different number of sugars, but the two disialoganglioside isomers, GD1a and GD1b, were coeluted. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:195 / 203
页数:9
相关论文
共 50 条
  • [41] Control of separation selectivity in capillary zone electrophoresis of inorganic anions
    Harakuwe, AH
    Haddad, PR
    JOURNAL OF CHROMATOGRAPHY A, 1999, 834 (1-2) : 213 - 232
  • [42] Determination of glycyrrhizin in liqueurs by on-line coupled capillary isotachophoresis with capillary zone electrophoresis
    Kvasnika, Frantisek
    Voldrich, Michal
    Vyhnalek, Josef
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1169 (1-2) : 239 - 242
  • [43] Capillary zone electrophoresis: Opportunities and challenges in miniaturization for environmental monitoring
    Jaywant, Swapna A.
    Singh, Harshpreet
    Arif, Khalid Mahmood
    SENSING AND BIO-SENSING RESEARCH, 2024, 43
  • [44] Capillary zone electrophoresis in wide bore capillary tubes with fiber-coupled diode array detection
    Strasík, S
    Danková, M
    Molnárová, M
    Ölvecká, E
    Kaniansky, D
    JOURNAL OF CHROMATOGRAPHY A, 2003, 990 (1-2) : 23 - 33
  • [45] Optimization of separation and migration behavior of cephalosporins in capillary zone electrophoresis
    Lin, CE
    Chen, HW
    Lin, EC
    Lin, KS
    Huang, HC
    JOURNAL OF CHROMATOGRAPHY A, 2000, 879 (02) : 197 - 210
  • [46] Origin and correction of bias caused by sample injection and detection in capillary zone electrophoresis
    vanderMoolen, JN
    Boelens, HFM
    Poppe, H
    Smit, HC
    JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) : 103 - 113
  • [47] Capillary electrophoresis-mass spectrometry for glycoscreening in biomedical research
    Zamfir, A
    Peter-Katalinic, J
    ELECTROPHORESIS, 2004, 25 (13) : 1949 - 1963
  • [48] Strategy for selecting separation solutions in capillary electrophoresis mass spectrometry
    Tanaka, Y
    Kishimoto, Y
    Otsuka, K
    Terabe, S
    JOURNAL OF CHROMATOGRAPHY A, 1998, 817 (1-2) : 49 - 57
  • [49] Capillary zone electrophoresis for the determination of average hydrodynamic velocity and diffusion coefficient
    Hongyi Zhang
    Xiurong Song
    Zhihong Shi
    Gengliang Yang
    Zhide Hu
    Fresenius' Journal of Analytical Chemistry, 1999, 365 : 499 - 503
  • [50] Asymmetry of protein peaks in capillary zone electrophoresis: effect of starting zone length and presence of polymer
    Radko, SP
    Chrambach, A
    Weiss, GH
    JOURNAL OF CHROMATOGRAPHY A, 1998, 817 (1-2) : 253 - 262