Photoplethysmographic signal aids indirect blood-pressure measurement

被引:0
|
作者
Jobbágy, A [1 ]
机构
[1] Budapest Univ Technol & Econ, Dept Measurement & Informat Syst, Budapest, Hungary
来源
MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2 | 2001年
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the daily routine blood-pressure is measured non-invasively. The presently used methods are not reliable, the precision (reproducibility) of instruments applying these methods is modest. The photoplethysmographic (PPG) signal recorded simultaneously with the cuff pressure helps eliminate erroneous results during indirect blood pressure measurement. The PPG signal can also be used to estimate the change in blood-pressure without applying a cuff. The time delay between the ECG R peak and the leading edge of the PPG signal is influenced also by the arterial blood-pressure. This method might be useful in applications when the tracking of changes in - and not the absolute value of - blood-pressure is important, e.g. in intensive care monitoring.
引用
收藏
页码:262 / 264
页数:3
相关论文
共 50 条
  • [21] INDIRECT MEASUREMENT OF ARTERIAL BLOOD-PRESSURE IN LABORATORY PONY
    HAHN, AW
    GARNER, HE
    COFFMAN, JR
    SANDERS, CW
    LABORATORY ANIMAL SCIENCE, 1973, 23 (06): : 889 - 893
  • [22] A NEW DEVICE FOR INDIRECT BLOOD-PRESSURE MEASUREMENT IN RABBITS
    KURASHINA, T
    SAKAMAKI, T
    YAGI, A
    NAKAMURA, T
    SAKAMOTO, H
    NUSHIRO, N
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1994, 58 (04): : 264 - 268
  • [23] DEVICE FOR HOME MEASUREMENT OF INDIRECT ARTERIAL BLOOD-PRESSURE
    TIEP, B
    RODBARD, S
    CIRCULATION, 1974, 50 (04) : 209 - 209
  • [24] VALUE TO FACILITATE INDIRECT MEASUREMENT OF ARTERIAL BLOOD-PRESSURE
    GOTT, U
    ANAESTHESIST, 1975, 24 (08): : 372 - 373
  • [25] A DEVICE FOR INDIRECT MEASUREMENT OF BLOOD-PRESSURE IN CONSCIOUS DOGS
    HORII, D
    HIGUCHI, T
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1985, 146 (04) : 479 - 480
  • [26] COMPARISON OF BLOOD-PRESSURE MEASUREMENT BY INDIRECT AND AUTOMATED TECHNIQUES
    JONES, LN
    MCMAHON, MA
    MCCARRON, DA
    PREVENTIVE MEDICINE, 1979, 8 (02) : 176 - 176
  • [27] Indirect measurement of the carotid arterial pressure from vibrocardiographic signal: calibration of the waveform and comparison with photoplethysmographic signal
    Casacanditella, L.
    Cosoli, G.
    Casaccia, S.
    Tomasini, E. P.
    Scalise, L.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 3568 - 3571
  • [28] INDIRECT BLOOD-PRESSURE MEASUREMENT DURING INTRAVENOUS ISOPRENALINE INFUSIONS
    ARNOLD, JMO
    MCDEVITT, DG
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1985, 19 (01) : 114 - 116
  • [29] INDIRECT AUSCULTATORY BLOOD-PRESSURE MEASUREMENT AT 2 SITES IN THE ARM
    TACHOVSKY, BJ
    RESEARCH IN NURSING & HEALTH, 1985, 8 (02) : 125 - 129
  • [30] CRITERIA IN CHOICE OF AN OCCLUDING CUFF FOR INDIRECT MEASUREMENT OF BLOOD-PRESSURE
    ALEXANDER, H
    COHEN, ML
    STEINFELD, L
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1977, 15 (01) : 2 - 10