Photoplethysmographic signal aids indirect blood-pressure measurement

被引:0
|
作者
Jobbágy, A [1 ]
机构
[1] Budapest Univ Technol & Econ, Dept Measurement & Informat Syst, Budapest, Hungary
来源
MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2 | 2001年
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the daily routine blood-pressure is measured non-invasively. The presently used methods are not reliable, the precision (reproducibility) of instruments applying these methods is modest. The photoplethysmographic (PPG) signal recorded simultaneously with the cuff pressure helps eliminate erroneous results during indirect blood pressure measurement. The PPG signal can also be used to estimate the change in blood-pressure without applying a cuff. The time delay between the ECG R peak and the leading edge of the PPG signal is influenced also by the arterial blood-pressure. This method might be useful in applications when the tracking of changes in - and not the absolute value of - blood-pressure is important, e.g. in intensive care monitoring.
引用
收藏
页码:262 / 264
页数:3
相关论文
共 50 条
  • [1] VARIABILITY IN INDIRECT BLOOD-PRESSURE MEASUREMENT
    BOTTINI, PB
    CARR, AA
    ARCHIVES OF INTERNAL MEDICINE, 1994, 154 (13) : 1536 - 1536
  • [2] INDIRECT METHODS OF BLOOD-PRESSURE MEASUREMENT
    MOSS, AJ
    PEDIATRIC CLINICS OF NORTH AMERICA, 1978, 25 (01) : 3 - 14
  • [3] INDIRECT BLOOD-PRESSURE MEASUREMENT IN DOG
    GARNER, HE
    HAHN, AW
    HARTLEY, JW
    HUTCHESON, DP
    COFFMAN, JR
    LABORATORY ANIMAL SCIENCE, 1975, 25 (02): : 197 - 202
  • [4] INDIRECT BLOOD-PRESSURE MEASUREMENT IN NEWBORNS
    DWECK, HS
    REYNOLDS, DW
    CASSADY, G
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1974, 127 (04): : 492 - 494
  • [5] ACCURACY OF INDIRECT BLOOD-PRESSURE MEASUREMENT IN THE ELDERLY
    OCALLAGHAN, WG
    FITZGERALD, DJ
    OMALLEY, K
    OBRIEN, E
    BRITISH MEDICAL JOURNAL, 1983, 286 (6377) : 1545 - 1546
  • [6] AUTOMATED INDIRECT BLOOD-PRESSURE MEASUREMENT - A RESPONSE
    REAM, AK
    MEDICAL INSTRUMENTATION, 1984, 18 (05): : 286 - 287
  • [7] AN ELECTRONIC INSTRUMENT FOR INDIRECT BLOOD-PRESSURE MEASUREMENT
    HOYT, BK
    WOLF, HK
    LANCET, 1984, 2 (8402) : 552 - 553
  • [8] AUSCULTATORY INDIRECT MEASUREMENT OF BLOOD-PRESSURE IN DOGS
    HARVEY, J
    FALSETTI, H
    COOPER, P
    DOWNING, D
    LABORATORY ANIMAL SCIENCE, 1983, 33 (04): : 370 - 372
  • [9] DIRECT VERSUS INDIRECT MEASUREMENT OF BLOOD-PRESSURE
    RAFTERY, EB
    JOURNAL OF HYPERTENSION, 1991, 9 : S10 - S12
  • [10] INFLUENCING FACTORS TO INDIRECT MEASUREMENT OF BLOOD-PRESSURE
    OKAHATA, S
    SHIMIZU, T
    KUWAHARA, T
    SATOH, I
    TAKAHASHI, O
    KAMIYA, T
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1985, 49 (08): : 825 - 825