A wearable sweat rate sensor to monitor the athletes' performance during training

被引:35
作者
Salvo, P. [1 ,2 ]
Pingitore, A. [2 ]
Barbini, A. [3 ]
Di Francesco, F. [1 ,4 ]
机构
[1] Univ Pisa, Dept Chem & Ind Chem, Via Moruzzi 13, I-56124 Pisa, Italy
[2] CNR, Inst Clin Physiol, Via Moruzzi 1, I-56124 Pisa, Italy
[3] CNR, Natl Inst Opt, Via Moruzzi 1, I-56124 Pisa, Italy
[4] Univ Pisa, Res Ctr E Piaggio, Largo Lazzarino 1, I-56122 Pisa, Italy
关键词
Sweat rate; Sports performance; Personalized training; Wearable sensor; Hydration;
D O I
10.1016/j.scispo.2017.03.009
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Objectives. -We developed a wearable sensor for the real time measurement of sweat rate in localized areas of the human body. This sensor represents the first step in the development of a wearable sensor network capable to estimate the global sweat rate via an ad hoc algorithm. Such device would be used to monitor athletes' hydration status during training and improve their performances. Equipment and methods. - For this study, we tested our sensor on thirteen football players during a cycling test on a cycle ergometer. The sweat rate sensor was compared to a medical device that, although measuring a different physiological process, provides discrete data based on the same working principle, i.e. the diffusion of the water vapour emitted from the skin. Results. -Our sensor has a working range up to 400 g/m(2) .h. The statistical analysis and the Bland-Altman plot proved that our sensor is comparable to the medical device used as gold standard. At low sweat rate, the bias is 3.4 g/m(2) .h with a standard deviation of 7.6 g/m(2) .h. At maximum sweat rates, the bias is 2.3 g/m(2) .11 with a standard deviation 6.9 g/m(2) .11. The Pvalues for the Bland-Altman plots at low and maximum sweat rate (0.1331 and 0.2477 obtained by Kolmogorov-Smimov test, respectively) allow the hypothesis that there is a significant difference between our sweat rate sensor and the medical device to be rejected. Conclusion. - We presented a prototype of a wearable sweat rate sensor for localized measurements. The trials on thirteen athletes proved that the performance of our sensor is comparable to that of a commercial medical device. This sweat rate sensor can provide valuable information on athletes' hydration status. (C) 2017 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:E51 / E58
页数:8
相关论文
共 34 条
[1]   A real-time interactive biofeedback system for sports training and rehabilitation [J].
Alahakone, A. U. ;
Senanayake, A. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2010, 224 (P2) :181-190
[2]   Stress-induced changes in skin barrier function in healthy women [J].
Altemus, M ;
Rao, B ;
Dhabhar, FS ;
Ding, WH ;
Granstein, R .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2001, 117 (02) :309-317
[3]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[4]   PREPARING SALAZAR,ALBERTO FOR THE HEAT OF THE 1984 OLYMPIC MARATHON [J].
ARMSTRONG, LE ;
HUBBARD, RW ;
JONES, BH ;
DANIELS, JT .
PHYSICIAN AND SPORTSMEDICINE, 1986, 14 (03) :73-&
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   IMPORTANCE OF DIETARY CHLORIDE FOR SALT SENSITIVITY OF BLOOD-PRESSURE [J].
BOEGEHOLD, MA ;
KOTCHEN, TA .
HYPERTENSION, 1991, 17 (01) :I158-I161
[7]   NUTRITION AND SPORTS PERFORMANCE [J].
BROTHERHOOD, JR .
SPORTS MEDICINE, 1984, 1 (05) :350-389
[8]  
Casa DJ, 2000, J ATHL TRAINING, V35, P212
[9]  
Clausen MJV, 2013, METAL IONS LIFE SCI, V12, P41, DOI 10.1007/978-94-007-5561-1_3
[10]   Comparison of closed chamber and open chamber evaporimetry [J].
Cohen, J. C. ;
Hartman, D. G. ;
Garofalo, M. J. ;
Basehoar, A. ;
Raynor, B. ;
Ashbrenner, E. ;
Akin, F. J. .
SKIN RESEARCH AND TECHNOLOGY, 2009, 15 (01) :51-54