Tailoring the synthesis of tantalum-based thin films for biomedical application: Characterization and biological response

被引:31
作者
Beline, Thamara [1 ,2 ]
da Silva, Jose H. D. [3 ]
Matos, Adaias O. [1 ,2 ]
Azevedo Neto, Nilton F. [3 ]
de Almeida, Amanda B. [1 ]
Nociti Junior, Francisco H. [1 ]
Leite, Douglas M. G. [4 ]
Rangel, Elidiane Cipriano [5 ]
Barao, Valentim A. R. [1 ,2 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, UNICAMP, Av Limeira 901, BR-13414903 Piracicaba, SP, Brazil
[2] Inst Biomat Tribocorros & Nanomed IBTN, Rio De Janeiro, RJ, Brazil
[3] Sao Paulo State Univ UNESP, Sch Sci, Dept Phys, Av Eng Luis Edmundo C Coube 14-01, BR-17033360 Bauru, SP, Brazil
[4] Technol Inst Aeronaut ITA, Plasma & Proc Lab, Pca Marechal Eduardo Gomes 50, BR-12228900 Sao Jose Dos Campos, SP, Brazil
[5] Sao Paulo State Univ UNESP, Inst Sci & Technol, Lab Technol Plasmas, Av Tres de Marco 511, BR-18087180 Sorocaba, SP, Brazil
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2019年 / 101卷
基金
巴西圣保罗研究基金会;
关键词
Dental implants; Magnetron sputtering; Tantalum oxide; Biofilms; Optical characterization; ELECTRICAL-PROPERTIES; OPTICAL-PROPERTIES; TITANIUM; BEHAVIOR; OXIDE; BIOCOMPATIBILITY; MODULATION; MORPHOLOGY; LAYER; ALLOY;
D O I
10.1016/j.msec.2019.03.072
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The aim of this study was to tailor the deposition parameters of magnetron sputtering to synthetize tantalum oxide (TaxOy) films onto commercially pure titanium (cpTi) surface. The structural and optical properties, morphology, roughness, elemental chemical composition and surface energy were assessed. The impact of TaxOy films on initial Streptococcus sanguinis adhesion was investigated. The morphology and spreading of pre-osteoblastic (MC3T3-E1) cells on a crystalline tantalum oxide film were evaluated. TaxOy films with estimated thickness of 600 nm and different structures (amorphous or crystalline) were produced depending on the various oxygen flow rates and parameters used. X-ray diffraction analysis revealed that the 8 O-2 sccm (600 degrees C/400 W) group showed crystallization corresponding to the beta-TaxO5 phase. Optical analysis showed that the 4 O-2 sccm (200 degrees C 300 W) to 8 O-2 sccm (600 degrees C 300 W) groups and 10 O-2 sccm (200 degrees C 300 W) group presented regular and large-amplitude interference oscillations, suggesting high optical homogeneity of the films. The crystalline beta-TaxO5 coating showed higher roughness and surface energy values than the other groups (P < .05) and was biocompatible. Compared with cpTi, the amorphous and crystalline tantalum oxide films did not increase bacterial adhesion (P > .05). By tailoring the deposition parameters, we synthetized a crystalline beta-TaxO5 coating that improved titanium surface properties and positively affected cell spreading and morphology, making it a promising surface treatment for titanium-based implants.
引用
收藏
页码:111 / 119
页数:9
相关论文
共 57 条
[1]   High power pulsed magnetron sputtering: Fundamentals and applications [J].
Alami, J. ;
Bolz, S. ;
Sarakinos, K. .
JOURNAL OF ALLOYS AND COMPOUNDS, 2009, 483 (1-2) :530-534
[2]   Statements from the Estepona Consensus Meeting on Peri-implantitis, February 2-4, 2012 [J].
Albrektsson, Tomas ;
Buser, Daniel ;
Chen, Stephen T. ;
Cochran, David ;
DeBruyn, Hugo ;
Jemt, Torsten ;
Koka, Sreenivas ;
Nevins, Myron ;
Sennerby, Lars ;
Simion, Massimo ;
Taylor, Thomas D. ;
Wennerberg, Ann .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (06) :781-782
[3]   Influence of magnetron sputtering conditions on the chemical bonding, structural, morphological and optical behavior of Ta1-xOx coatings [J].
Almeida Alves, C. F. ;
Mansilla, C. ;
Pereira, L. ;
Paumier, F. ;
Girardeau, T. ;
Carvalho, S. .
SURFACE & COATINGS TECHNOLOGY, 2018, 334 :105-115
[4]   Bioactivity response of Ta1-xOx coatings deposited by reactive DC magnetron sputtering [J].
Almeida Alves, C. F. ;
Cavaleiro, A. ;
Carvalho, S. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 58 :110-118
[5]  
[Anonymous], 1964, J LESS COM MET, DOI DOI 10.1016/0022-5088(64)90036-0
[6]   Modulation of cell adhesion, proliferation and differentiation on materials designed for body implants [J].
Bacakova, Lucie ;
Filova, Elena ;
Parizek, Martin ;
Ruml, Tomas ;
Svorcik, Vaclav .
BIOTECHNOLOGY ADVANCES, 2011, 29 (06) :739-767
[7]   Performances exhibited by large area ITO layers produced by rf magnetron sputtering [J].
Baía, I ;
Quintela, M ;
Mendes, L ;
Nunes, P ;
Martins, R .
THIN SOLID FILMS, 1999, 337 (1-2) :171-175
[8]   Direct laser processing of a tantalum coating on titanium for bone replacement structures [J].
Balla, Vamsi Krishna ;
Banerjee, Shashwat ;
Bose, Susmita ;
Bandyopadhyay, Amit .
ACTA BIOMATERIALIA, 2010, 6 (06) :2329-2334
[9]   The role of nicotine, cotinine and caffeine on the electrochemical behavior and bacterial colonization to cp-Ti [J].
Barao, Valentim A. R. ;
Ricomini-Filho, Antonio P. ;
Faverani, Leonardo P. ;
Del Bel Cury, Altair A. ;
Sukotjo, Cortino ;
Monteiro, Douglas R. ;
Yuan, Judy Chia-Chun ;
Mathew, Mathew T. ;
do Amaral, Regiane C. ;
Mesquita, Marcelo E. ;
da Silva, Wander J. ;
Assuncao, Wirley G. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 56 :114-124
[10]   Clinical Outcomes Measures for Assessment of Longevity in the Dental Implant Literature: ORONet Approach [J].
Bassi, Francesco ;
Carr, Alan B. ;
Chang, Ting-Ling ;
Estafanous, Emad ;
Garrett, Neal R. ;
Happonen, Risto-Pekka ;
Koka, Sreenivas ;
Laine, Juhani ;
Osswald, Martin ;
Reintsema, Harry ;
Rieger, Jana ;
Roumanas, Eleni ;
Salinas, Thomas J. ;
Stanford, Clark M. ;
Wolfaardt, Johan .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2013, 26 (04) :323-330