Thousand-fold fluorescent signal amplification for mHealth diagnostics

被引:16
作者
Balsam, Joshua [1 ,2 ]
Rasooly, Reuven [3 ]
Bruck, Hugh Alan [2 ]
Rasooly, Avraham [1 ,4 ]
机构
[1] FDA, Div Biol, Off Sci & Engn, Silver Spring, MD 20993 USA
[2] Univ Maryland, College Pk, MD 20742 USA
[3] ARS, Western Reg Res Ctr, USDA, Albany, CA 94710 USA
[4] NCI, Div Canc Biol, Bethesda, MD 20892 USA
关键词
Lab-on-a-chip; mHealth; Capillary; Fluorescence; Image stacking; Mobile phone; CELL-PHONE; BIOSENSOR; IMMUNOSENSOR; IMMUNOASSAY; PLATFORM; HEALTH; SENSOR; POINT;
D O I
10.1016/j.bios.2013.06.053
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The low sensitivity of Mobile Health (mHealth) optical detectors, such as those found on mobile phones, is a limiting factor for many mHealth clinical applications. To improve sensitivity, we have combined two approaches for optical signal amplification: (1) a computational approach based on an image stacking algorithm to decrease the image noise and enhance weak signals, and (2) an optical signal amplifier utilizing a capillary tube array. These approaches were used in a detection system which includes multi-wavelength LEDs capable of exciting many fluorophores in multiple wavelengths, a mobile phone or a webcam as a detector, and capillary tube array configured with 36 capillary tubes for signal enhancement. The capillary array enables a similar to 100 x increase in signal sensitivity for fluorescein, reducing the limit of detection (LOD) for mobile phones and webcams from 1000 nM to 10 nM. Computational image stacking enables another similar to 10 x increase in signal sensitivity, further reducing the LOD for webcam from 10 nM to 1 nM. To demonstrate the feasibility of the device for the detection of disease-related biomarkers, adenovirus DNA labeled with SYBR green or fluorescein was analyzed by both our capillary array and a commercial plate reader. The LOD for the capillary array was 5 ug/mL, and that of the plate reader was 1 ug/mL. Similar results were obtained using DNA stained with fluorescein. The combination of the two signal amplification approaches enables a similar to 1000 x increase in LOD for the webcam platform. This brings it into the range of a conventional plate reader while using a smaller sample volume (10 ul) than the plate reader requires (100 ul). This suggests that such a device could be suitable for biosensing applications where up to 10 fold smaller sample sizes are needed. The simple optical configuration for mHealth described in this paper employing the combined capillary and image processing signal amplification is capable of measuring weak fluorescent signals without the need of dedicated laboratories. It has the potential to be used to increase sensitivity of other optically based mHealth technologies, and may increase mHealth's clinical utility, especially for telemedicine and for resource-poor settings and global health applications. Published by Elsevier B.V.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 35 条
[1]   Multi-analyte interrogation using the fiber optic biosensor [J].
Anderson, GP ;
King, KD ;
Gaffney, KL ;
Johnson, LH .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11) :771-777
[2]   Image stacking approach to increase sensitivity of fluorescence detection using a low cost complementary metal-oxide-semiconductor (CMOS) webcam [J].
Balsam, Joshua ;
Bruck, Hugh Alan ;
Kostov, Yordan ;
Rasooly, Avraham .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 :141-147
[3]   Modeling and design of micromachined optical Soller collimators for lensless CCD-based fluorometry [J].
Balsam, Joshua ;
Ossandon, Miguel ;
Bruck, Hugh Alan ;
Rasooly, Avraham .
ANALYST, 2012, 137 (21) :5011-5017
[4]  
Balsam J, 2011, LAB CHIP, V11, P941, DOI [10.1039/c0lc00431f, 10.1039/c01c00431f]
[5]   Integrated immunoassay using tuneable surface acoustic waves and lensfree detection [J].
Bourquin, Yannyk ;
Reboud, Julien ;
Wilson, Rab ;
Zhang, Yi ;
Cooper, Jonathan M. .
LAB ON A CHIP, 2011, 11 (16) :2725-2730
[6]   The Remote Assessment of Melanocytic Skin Lesions: A Viable Alternative to Face-to-Face Consultation [J].
Boyce, Z. ;
Gilmore, S. ;
Xu, C. ;
Soyer, H. P. .
DERMATOLOGY, 2011, 223 (03) :244-250
[7]   Capillary biosensor for glutamate [J].
Cosford, RJO ;
Kuhr, WG .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2164-2169
[8]  
Flanagan M.T., 1992, Waveguide Sensor with Input and Reflecting Grating and its use in Immunoassay
[9]  
Hay Burgess Deborah C, 2006, Nature, V444 Suppl 1, P1
[10]   Introduction to the special section on m-Health: Beyond seamless mobility and global wireless health-care connectivity [J].
Istepanian, RSH ;
Jovanov, E ;
Zhang, YT .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2004, 8 (04) :405-414