Acceleration-based gait test for healthy subjects: Reliability and reference data

被引:103
作者
Senden, R. [1 ,2 ]
Grimm, B. [1 ]
Heyligers, I. C. [1 ]
Savelberg, H. H. C. M. [2 ]
Meijer, K. [2 ]
机构
[1] Atrium Med Ctr, Dept Orthopaed & Traumatol, NL-6401 CX Heerlen, Netherlands
[2] Maastricht Univ, Dept Human Movement Sci, NL-6229 ER Maastricht, Netherlands
关键词
Gait; Accelerometer; Repeatability; Reference data; TEST-RETEST RELIABILITY; PARAMETERS; ACCELEROMETRY; WALKING; YOUNG; QUANTIFICATION; VALIDITY; PATTERNS; SYSTEM; IDEEA;
D O I
10.1016/j.gaitpost.2009.04.008
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Accelerometers enable us to analyse gait outside conventional gait laboratories. Before these devices can be used in large scale studies and in clinical settings a thorough evaluation of their performance in different populations is required. The aim of this study was to present an acceleration-based reference database for healthy gait. The repeatability and inter-observer reliability of acceleration-based gait analysis was investigated. The sensitivity was tested on different age groups and the effect of gender was studied. A comprehensive set of gait parameters (i.e. cadence, speed, asymmetry and irregularity) were studied in 60 women and 60 men. Basic gait parameters showed high repeatability (VCcadence 1.51%, ICCcadence 0.996) and inter-observer reliability (ICCcadence 0.916), while asymmetry and irregularity showed lower repeatability VCasym 47.88%, ICCasym 0.787) and inter-observer reliability (ICCasym 0.449). The effects of age and gender on gait parameters were found to be consistent with those reported in studies using other methodologies. These findings and the advantages of the device support the application of AGA for routine clinical use and in daily life. (C) 2009 Elsevier BY. All rights reserved.
引用
收藏
页码:192 / 196
页数:5
相关论文
共 29 条
[1]   Reliability of diabetic patients' gait parameters in a challenging environment [J].
Allet, L. ;
Armand, S. ;
de Bie, R. A. ;
Golay, A. ;
Monnin, D. ;
Aminian, K. ;
de Bruin, E. D. .
GAIT & POSTURE, 2008, 28 (04) :680-686
[2]   Reference data for normal subjects obtained with an accelerometric device [J].
Auvinet, B ;
Berrut, G ;
Touzard, C ;
Moutel, L ;
Collet, N ;
Chaleil, D ;
Barrey, E .
GAIT & POSTURE, 2002, 16 (02) :124-134
[3]   Accelerometry based assessment of gait parameters in children [J].
Brandes, Mirko ;
Zijlstra, Wiebren ;
Heikens, Sander ;
van Lummel, Rob ;
Rosenbaum, Dieter .
GAIT & POSTURE, 2006, 24 (04) :482-486
[4]   Reliability of videotaped observational gait analysis in patients with orthopedic impairments [J].
Brunnekreef, JJ ;
van Uden, CJT ;
van Moorsel, S ;
Kooloos, JGM .
BMC MUSCULOSKELETAL DISORDERS, 2005, 6 (1)
[5]   Managing variability in the summary and comparison of gait data [J].
Chau T. ;
Young S. ;
Redekop S. .
Journal of NeuroEngineering and Rehabilitation, 2 (1)
[6]   Gender differences in three dimensional gait analysis data from 98 healthy Korean adults [J].
Cho, SH ;
Park, JM ;
Kwon, OY .
CLINICAL BIOMECHANICS, 2004, 19 (02) :145-152
[7]   STRIDE-DEPENDENT CHANGES IN GAIT OF OLDER-PEOPLE [J].
ELBLE, RJ ;
THOMAS, SS ;
HIGGINS, C ;
COLLIVER, J .
JOURNAL OF NEUROLOGY, 1991, 238 (01) :1-5
[8]  
Grimm B, 2006, J BIOMECH, V39, pS110
[9]  
Hausdorff Jeffrey M, 2005, J Neuroeng Rehabil, V2, P19
[10]   Test-retest reliability of trunk accelerometric gait analysis [J].
Henriksen, M ;
Lund, H ;
Moe-Nilssen, R ;
Bliddal, H ;
Danneskiod-Samsoe, B .
GAIT & POSTURE, 2004, 19 (03) :288-297