Ambient air sampling for tritium-determination of breakthrough volumes and collection efficiencies for silica gel adsorbent

被引:8
作者
Patton, GW [1 ]
Cooper, AT [1 ]
Tinker, MR [1 ]
机构
[1] PACIFIC NW LAB, RICHLAND, WA 99352 USA
来源
HEALTH PHYSICS | 1997年 / 72卷 / 03期
关键词
air sampling; tritium; adsorption; radioactivity; airborne;
D O I
10.1097/00004032-199703000-00007
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ambient air samples for tritium (as HTO) can be collected using the solid adsorbent silica gel. The purpose of this study was to determine the maximum practical sampling volume and overall collection efficiency for water vapor collected on silica gel columns and to demonstrate the use of an impinger-based system to load water vapor onto silica gel columns. Breakthrough volumes (V-b) were measured and chromatographic efficiencies (expressed as the number of theoretical plates, N) were calculated for a 20 degrees C to 50 degrees C temperature range, with the relative humidity at approximately 30%. The tests yielded relative breakthrough volumes (air volume/adsorbent depth, m(3) cm(-1)) of 0.36 for 20 degrees C, 0.20 for 30 degrees C, 0.15 for 40 degrees C, and 0.077 for 50 degrees C. For 18-cm columns, the average tritium tracer recoveries at 20 degrees C were 71% with no observed breakthrough for air volumes up to 5 m(3), while at 40 degrees C mean tritium tracer recoveries dropped from 75% for volumes less than or equal to 3.0 m(3), to 0% for a volume of 5.0 m(3). Frontal chromatographic profiles were measured for water vapor migrating through silica gel columns that were divided into 5 segments. The chromatographic efficiency of the silica gel columns was determined by graphical evaluation of the chromatography profiles. At a sampling rate of 0.25 L min(-1) and 30% relative humidity, the number of theoretical plates per adsorbent depth were 0.55 N cm(-1) at 20 degrees C, 0.68 N cm(-1) at 30 degrees C, 0.51 N cm(-1) at 40 degrees C, and 0.30 N cm(-1) at 50 degrees C. Chromatographic theory was used to estimate the overall collection efficiency of the silica gel columns as a function of the ratio of the sampling volume to breakthrough volume and the chromatographic efficiency. For a 9.5 m(3) sample volume, 30% relative humidity, 0.25 L min(-1) sampling rate, and a 54-cm column, the overall collection efficiency was above 99.9% at 20 degrees C, above 95% at 30 degrees C, just below 80% at 40 degrees C, and much less than 80% at 50 degrees C.
引用
收藏
页码:397 / 407
页数:11
相关论文
共 16 条
[1]  
BIDLEMAN TF, 1985, TRACE ANAL, V4, P51
[2]   COLLECTION AND ANALYSIS OF TRACE ORGANIC VAPOR POLLUTANTS IN AMBIENT ATMOSPHERES - PERFORMANCE OF A TENAX-GC ADSORBENT TUBE [J].
BROWN, RH ;
PURNELL, CJ .
JOURNAL OF CHROMATOGRAPHY, 1979, 178 (01) :79-90
[3]   TRITIUM INSTRUMENTATION FOR ENVIRONMENTAL AND OCCUPATIONAL MONITORING - REVIEW [J].
BUDNITZ, RJ .
HEALTH PHYSICS, 1974, 26 (02) :165-+
[4]  
Dean JA., 1992, Lange's handbook of chemistry
[5]  
DIRKES RL, 1994, HANFORD SITE ENV REP
[6]  
Eisenbud M., 1987, Environmental Radioactivity, Vsecond
[7]   METABOLISM AND DOSIMETRY OF TRITIUM [J].
HILL, RL ;
JOHNSON, JR .
HEALTH PHYSICS, 1993, 65 (06) :628-647
[8]  
Lodge Jr J.P., 1989, METHODS AIR SAMPLING
[9]  
PATTON GW, 1993, AIR PATHWAY EFFECTS
[10]  
POOLE CF, 1984, CONT PRACTICE CHROMA