Numerical simulation research on delaminlation phenomena of ordinary air-conditioned room

被引:0
作者
Wang, HQ [1 ]
Tang, GF [1 ]
Huang, CH [1 ]
Kou, GX [1 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
来源
PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III | 2001年
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper we discuss the phenomena of hot air jet in an ordinary air-conditioned room. Numerical simulation method is used to study the problem. Both CTFFP program and Phoenix program are used to take a comparison between their results. We find both of them can predict the flow field well. Several factors to influence the delaminating problem, such as the height of the inlet, the angle of the supplied air jet and heat flux direction are discussed in the paper.
引用
收藏
页码:1817 / 1824
页数:8
相关论文
共 50 条
[31]   Simulation of Thermal Comfort Conditions of an Air-Conditioned Cafeteria in the Tropics [J].
Zainuddin, A. ;
Adam, N. M. ;
Rusli, I. H. ;
Kwong, Q. J. .
ADVANCES IN MECHANICAL AND MANUFACTURING ENGINEERING, 2014, 564 :263-+
[32]   EXERGY STUDY OF AIR-CONDITIONED SPACE OF A PROTOTYPE SCALE OF A RIVER VESSEL ROOM [J].
Fajardo, J. ;
Sarria, B. ;
Alvarez Guerra, M. ;
Cruz, O. .
PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2016, VOL. 6B, 2017,
[33]   Modeling with simulink and bond graph method for fault detection in an air-conditioned room [J].
Yu, B ;
van Paassen, AHC .
PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, :1163-1170
[34]   Numerical studies on the indoor air flow in the occupied zone of ventilated and air-conditioned space [J].
Chow, WK ;
Fung, WY .
BUILDING AND ENVIRONMENT, 1996, 31 (04) :319-344
[35]   Simulation and Analyse on Thermal Characters and Energy Consumption in Air-conditioned Building [J].
Qu, Ruigui .
PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION (ICMS2009), VOL 3, 2009, :134-139
[36]   STUDIES ON ECTOMYCORRHIZAE OF PINE IN AN ELECTRONICALLY AIR-FILTERED, AIR-CONDITIONED, PLANT-GROWTH ROOM [J].
MARX, DH ;
BRYAN, WC .
CANADIAN JOURNAL OF BOTANY, 1969, 47 (12) :1903-&
[37]   SUMMER SEMEN CHARACTERISTICS OF RAMS HAVING FREE ACCESS TO A PLASTIC AIR-CONDITIONED ROOM [J].
SIMPSON, EC ;
RICE, HC ;
STEELE, DG .
JOURNAL OF ANIMAL SCIENCE, 1959, 18 (03) :1157-1158
[38]   Transient analysis and improvement of indoor thermal comfort for an air-conditioned room with thermal insulations [J].
Prakash, D. .
AIN SHAMS ENGINEERING JOURNAL, 2015, 6 (03) :947-956
[39]   Numerical Study of Limiting the Spread of Sarin (GB) in an Air-conditioned Aircraft Cabin [J].
Farag, Ahmed Mohamed ;
Khalil, Essam E. ;
Hassan, Mohamed M. .
14TH INTERNATIONAL ENERGY CONVERSION ENGINEERING CONFERENCE, 2016,
[40]   A Numerical Study of the Indoor Thermal Environment in an Air-conditioned Large Space Building [J].
Liu Jiying .
PROCEEDINGS OF 8TH INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION (ICICTA 2015), 2015, :69-72