摘要
The tomography setup developed at the PGA facility of the Swiss spallation source SINQ has provided encouraging results in the field of cold neutron imaging. Performances of the detection system based on a CCD camera and a converter screen have been recently improved using (LiF)-Li-6/ZnS:Ag scintillators with different thickness. Indeed, reducing the layer of the scintillator improved considerably the spatial resolution while keeping a reasonable efficiency. Furthermore, a neutron velocity selector was temporarily added to the setup to perform radiography and tomography experiments with monochromatic neutron beams. Basic properties of transmitted beams were studied to assess the applicability of this device in neutron imaging. Of interest was the enhancement of the L/D-ratio by selecting neutron beams of short wavelengths. Cold neutron tomography demonstrated to be a useful technique in various spheres of activity, such as aerospatial industry or radioactive waste storage. Various applications of the neutron velocity selector are described in the second part, namely, New features in cold neutron radiography and tomography-Part II: Applied energy-selective neutron radiography and tomography. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:481 / 491
页数:11
相关论文
共 16 条
[1]   The new cold neutron tomography set-up at SINQ [J].
Baechler, S ;
Masschaele, B ;
Cauwels, P ;
Dierick, M ;
Jolie, J ;
Materna, T ;
Mondelaers, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 481 (1-3) :397-405
[2]  
BAECHLER S, 2001, LABOUR RADIO UMWELTC, P34
[3]   Operation and development of the new spallation neutron source SINQ at the Paul Scherrer Institut [J].
Bauer, GS .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 139 (1-4) :65-71
[4]   Present applications of neutron radiography in France [J].
Bayon, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 424 (01) :92-97
[5]  
HARMS AA, 1986, MATH PHYSICS NEUTRON
[6]  
HERMAN GT, 1980, IMAGE RECONSTRUCTION
[7]  
KARDJILOV N, 2001, IN PRESS J APPL RAD
[8]  
Kobayashi H., 1990, NEUTRON RADIOGRAPHY, V3, P889
[9]  
KOBAYASHI H, 2000, NEUTRON RADIOGRAPHY, V6, P167
[10]  
KUHNE G, PSI ANN REPORT 1999, P70