The complications associated with Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA)

被引:121
作者
Ribeiro Junior, Marcelo A. F. [1 ]
Feng, Celia Y. D. [2 ]
Nguyen, Alexander T. M. [2 ]
Rodrigues, Vinicius C. [1 ]
Bechara, Giovana E. K. [1 ]
de-Moura, Raissa Reis [1 ]
Brenner, Megan [3 ]
机构
[1] Univ Santo Amaro, Disciplina Cirurgia Geral & Trauma, Sao Paulo, SP, Brazil
[2] Univ New South Wales, Sch Med, Sydney, NSW, Australia
[3] Univ Maryland, RA Cowley Shock Trauma Ctr, Baltimore, MD 21201 USA
关键词
Complications; Radiology; Interventional; Multiple trauma; Abdomen; Shock; Hemorrhagic; REBOA; HEMORRHAGIC-SHOCK; TORSO HEMORRHAGE; STRATEGIES; MANAGEMENT; ADJUNCT; MODEL;
D O I
10.1186/s13017-018-0181-6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Non-compressible torso hemorrhage (NCTH) remains a significant cause of morbidity and mortality in the field of trauma and emergency medicine. In recent times, there has been a resurgence in the adoption of Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) for patients who present with NCTH. Like all medical procedures, there are benefits and risks associated with the REBOA technique. However, in the case of REBOA, these complications are not unanimously agreed upon with varying viewpoints and studies. This article aims to review the current knowledge surrounding the complications of the REBOA technique at each step of its application.
引用
收藏
页数:6
相关论文
共 27 条
[11]   The compatibility of computed tomography scanning and partial REBOA: A large animal pilot study [J].
Madurska, Marta J. ;
Jansen, Jan O. ;
Reva, Viktor A. ;
Mirghani, Mohammed ;
Morrison, Jonathan J. .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2017, 83 (03) :557-561
[12]   Intra-Aortic Balloon Occlusion to Salvage Patients With Life-Threatening Hemorrhagic Shocks From Pelvic Fractures [J].
Martinelli, Thomas ;
Thony, Frederic ;
Declety, Philippe ;
Sengel, Christian ;
Broux, Christophe ;
Tonetti, Jerome ;
Payen, Jean-Francois ;
Ferretti, Gilbert .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 68 (04) :942-948
[13]   Fewer REBOA complications with smaller devices and partial occlusion: evidence from a multicentre registry in Japan [J].
Matsumura, Yosuke ;
Matsumoto, Junichi ;
Kondo, Hiroshi ;
Idoguchi, Koji ;
Ishida, Tokiya ;
Kon, Yuri ;
Tomita, Keisuke ;
Ishida, Kenichiro ;
Hirose, Tomoya ;
Umakoshi, Kensuke ;
Funabiki, Tomohiro .
EMERGENCY MEDICINE JOURNAL, 2017, 34 (12) :793-799
[14]   Noncompressible Torso Hemorrhage A Review with Contemporary Definitions and Management Strategies [J].
Morrison, Jonathan J. ;
Rasmussen, Todd E. .
SURGICAL CLINICS OF NORTH AMERICA, 2012, 92 (04) :843-+
[15]   A systematic review of the use of resuscitative endovascular balloon occlusion of the aorta in the management of hemorrhagic shock [J].
Morrison, Jonathan James ;
Galgon, Richard E. ;
Jansen, Jan Olaf ;
Cannon, Jeremy W. ;
Rasmussen, Todd Erik ;
Eliason, Jonathan L. .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2016, 80 (02) :324-334
[16]  
Okada Y, 2016, J SURG CASE REP, V2, P1
[17]  
Ordoñez Carlos A., 2017, Rev. colomb. anestesiol., V45, P30
[18]   Resuscitative endovascular balloon occlusion of the aorta [J].
Qasim, Zaffer ;
Brenner, Megan ;
Menaker, Jay ;
Scalea, Thomas .
RESUSCITATION, 2015, 96 :275-279
[19]  
RIBEIRO JÚNIOR MARCELO AUGUSTO FONTENELLE, 2018, Rev. Col. Bras. Cir., V45, pe1709, DOI 10.1590/0100-6991e-20181709
[20]   Partial Resuscitative Endovascular Balloon Occlusion of the Aorta in Swine Model of Hemorrhagic Shock [J].
Russo, Rachel M. ;
Neff, Lucas P. ;
Lamb, Christopher M. ;
Cannon, Jeremy W. ;
Galante, Joseph M. ;
Clement, Nathan F. ;
Grayson, J. Kevin ;
Williams, Timothy K. .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2016, 223 (02) :359-368