A flexible and high throughput liquid chromatography-tandem mass spectrometric assay for the quantitation of telcagepant in human plasma

被引:1
|
作者
Du, Lihong [1 ]
Miller-Stein, Cynthia M. [1 ]
Valesky, Robert J. [1 ]
Martucci, Ashley N. [1 ]
Woolf, Eric J. [1 ]
机构
[1] Merck & Co Inc, Dept Clin PK PD, Merck Res Labs, West Point, PA 19486 USA
关键词
Telcagepant (MK-0974); Protein precipitation; Human plasma; LC-MS/MS; RECEPTOR ANTAGONIST; MIGRAINE; CGRP; MK-0974; ELECTROSPRAY; STRATEGIES; SAMPLES;
D O I
10.1016/j.jchromb.2009.03.019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Telcagepant (MK-0974) is a novel oral calcitonin gene-related peptide (CGRP) receptor antagonist and is currently under clinical development. Results from phases II and III clinical trials have Suggested that telcagepant is effective for migraine treatment. A reliable and high throughput protein precipitation (PPT) method for determination of telcagepant in human plasma using liquid chromatography coupled with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry has been developed. Clinical samples, internal standard (IS) and acetonitrile are transferred into 96-well plates using a robotic liquid handling system. An aliquot of 10 mu L supernatant is directly injected into the LC-MS/MS system where separation is performed on a FluoPhase RP (150 x 2.1 mm, 5 mu m) column with an isocratic mobile phase (60% acetonitrile with 0.1% formic acid and 40% water with 0.1% formic acid)at 0.2 mL/min. The interfering 3S-diastereomer of telcagepant, which is observed in clinical samples, is chromatographically resolved from telcagepant. The PPT procedure significantly reduces the time required for sample processing and the assay is sufficiently sensitive for detection using both API 4000 and API 3000 mass spectrometers. The linear calibration range is 5-5000 nM using 200 mu L of plasma. Assay intraday validation was conducted using Six calibration Curves derived from six lots of human control plasma. Calibration standard accuracy did not deviate by more than 3% and 6% of nominal values, and precision did not exceed 4% coefficient of variation (CV) and 10% CV, respectively on the Apt 4000 and API 3000. Several clinical phases IIb and III Studies have been successfully supported with this assay. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1465 / 1471
页数:7
相关论文
共 50 条
  • [21] Bioanalytical applications of 'fast chromatography' to high-throughput liquid chromatography/tandem mass spectrometric quantitation
    Romanyshyn, L
    Tiller, PR
    Hop, CECA
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (18) : 1662 - 1668
  • [23] High-throughput liquid chromatography-tandem mass spectrometry assay for plasma theophylline and its metabolites
    Song, J
    Park, KU
    Park, HD
    Yoon, Y
    Kim, JQ
    CLINICAL CHEMISTRY, 2004, 50 (11) : 2176 - 2179
  • [24] Liquid chromatography-electrospray tandem mass spectrometric assay suitable for quantitation of halofuginone in plasma
    Parise, RA
    Sparrow, BR
    Merrill, JW
    Grossi, IM
    Covey, JM
    Peggins, JO
    Egorin, MJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 810 (01): : 35 - 40
  • [25] Liquid chromatography-tandem mass spectrometric assay for the quantitation in human plasma of the novel indenoisoquinoline topoisomerase I inhibitors, NSC 743400 and NSC 725776
    Holleran, Julianne L.
    Parise, Robert A.
    Yellow-Duke, Archibong E.
    Egorin, Merrill J.
    Eiseman, Julie L.
    Covey, Joseph M.
    Beumer, Jan H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (05) : 714 - 720
  • [26] HIGH-THROUGHPUT DETERMINATION OF LINEZOLID IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Vlase, Laurian
    Muntean, Dana
    Cuciureanu, Magdalena
    Cuciureanu, Rodica
    Gocan, Simion
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (08) : 591 - 600
  • [27] HIGH-THROUGHPUT DETERMINATION OF LINEZOLID IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Vlase, Laurian
    Muntean, Dana
    Cuciureanu, Magdalena
    Cuciureanu, Rodica
    Gocan, Simion
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (06) : 436 - 445
  • [28] A rapid and sensitive liquid chromatography-tandem mass spectrometric assay for duloxetine in human plasma:Its pharmacokinetic application
    Ramakrishna Gajula
    Rambabu Maddela
    Vasu Babu Ravi
    Jaswanth Kumar Inamadugu
    Nageswara Rao Pilli
    JournalofPharmaceuticalAnalysis, 2013, 3 (01) : 36 - 44
  • [29] Development and validation of a liquid chromatography-tandem mass spectrometric assay for pitavastatin and its lactone in human plasma and urine
    Tian, Lei
    Huang, Yiling
    Jia, Youhong
    Hua, Lu
    Li, Yishi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 865 (1-2): : 127 - 132
  • [30] Development and validation of a liquid chromatography-tandem mass spectrometric assay for Eplerenone and its hydrolyzed metabolite in human plasma
    Zhang, JY
    Fast, DM
    Breau, AP
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 787 (02): : 333 - 344