Monitoring surgical performance: an application to total hip replacement

被引:17
作者
Biau, David J. [1 ,2 ]
Milet, Alexandre [3 ]
Thevenin, Fabrice [4 ]
Anract, Philippe [1 ]
Porcher, Raphael [2 ]
机构
[1] Univ Paris 05, Hop Cochin, AP HP, Dept Chirurg Orthoped, F-75270 Paris 06, France
[2] Univ Paris 07, Hop St Louis, AP HP, Dept Biostat & Informat Med,INSERM UMR S 717, F-75221 Paris, France
[3] Clin Chirurg Pre, Le Mans, France
[4] Univ Paris 05, Hop Cochin, AP HP, Dept Radiol B, F-75270 Paris 06, France
关键词
clinical evaluation; CUSUM; hip replacement; performance; quality control; surgery; RADIOLOGICAL FEATURES; ARTHROPLASTY; ORIENTATION; DISLOCATION; COMPETENCE; CUSUM;
D O I
10.1111/j.1365-2753.2008.01029.x
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Inadequate surgical implantation of a hip replacement may result in decreased patient satisfaction and reduced implant survival. The objective was to monitor surgical performance in hip replacement. The study took place at a teaching centre. All primary total hip replacements were prospectively included in the series. For each hip replacement, intraoperative technical errors, cup and stem fixation and position, and postoperative complications were recorded. If all items rated were correct, the procedure was considered as correct. The Cumulative Sums (CUSUM) test was used to monitor the performance of the centre. A 90% proportion of successful procedures was considered as adequate performance and a 75% proportion of successful procedures was deemed as inadequate performance. Meetings were conducted to discuss the results of monitoring. Eighty-three total hip replacements were monitored. Overall, 28 procedures (34%) were considered inadequate. The most potent reasons for inadequate performance were cup positioning and stem fixation. The CUSUM test signalled after the second procedure that performance was inadequate. After the first meeting, despite an improvement was seen, the CUSUM test raised an alarm indicating inadequate performance. The study was stopped after the second meeting because of funding reasons before it could be demonstrated that performance had reached the desired level. This study has demonstrated that implementing a dedicated system to monitor surgical performance in a teaching hospital improves the quality of implantation of total hip replacements. Nonetheless, the target of ninety percent of adequate primary total hip replacement could not be reached and efforts should be continued.
引用
收藏
页码:420 / 424
页数:5
相关论文
共 24 条
[1]   THE HIDDEN EFFECT OF TIME [J].
ALTMAN, DG ;
ROYSTON, JP .
STATISTICS IN MEDICINE, 1988, 7 (06) :629-637
[2]  
[Anonymous], 2001, INQUIRY MANAGEMENT C
[3]   IMPROVED CEMENTING TECHNIQUES AND FEMORAL COMPONENT LOOSENING IN YOUNG-PATIENTS WITH HIP-ARTHROPLASTY - A 12-YEAR RADIOGRAPHIC REVIEW [J].
BARRACK, RL ;
MULROY, RD ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :385-389
[4]   Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements - Factors affecting survivorship of acetabular and femoral components [J].
Berry, DJ ;
Harmsen, WS ;
Cabanela, ME ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (02) :171-177
[5]   Quality control of surgical and interventional procedures: a review of the CUSUM [J].
Biau, David J. ;
Resche-Rigon, Mathieu ;
Godiris-Petit, Gae ;
Nizard, Remy S. ;
Porcher, Raphael .
QUALITY & SAFETY IN HEALTH CARE, 2007, 16 (03) :203-207
[6]   Poor accuracy of freehand cup positioning during total hip arthroplasty [J].
Bosker, B. H. ;
Verheyen, C. C. P. M. ;
Horstmann, W. G. ;
Tulp, N. J. A. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (05) :375-379
[7]   Results of Charnley total hip arthroplasty at a minimum of thirty years - A concise follow-up of a previous report [J].
Callaghan, JJ ;
Templeton, JE ;
Liu, SS ;
Pedersen, DR ;
Goetz, DD ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (04) :690-695
[8]   Radiological features predictive of aseptic loosening in cemented Charnley femoral stems [J].
Chambers, IR ;
Fender, D ;
McCaskie, AW ;
Reeves, BC ;
Gregg, PJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06) :838-842
[9]   THE CEMENT MANTLE IN TOTAL HIP-ARTHROPLASTY - ANALYSIS OF LONG-TERM RADIOGRAPHIC RESULTS [J].
EBRAMZADEH, E ;
SARMIENTO, A ;
MCKELLOP, HA ;
LLINAS, A ;
GOGAN, W .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (01) :77-87
[10]  
Hardoon SL, 2006, J BONE JOINT SURG BR, V88B, P716, DOI 10.1302/0301-620X.88B6